ADD the bwmsetcap command function
Signed-off-by: Niel Nielsen <nieldk@gmail.com>
This commit is contained in:
1 parent
cc98f9560b
commit
6c605c3f5d
1 file changed
+44
@@ -1500,6 +1500,49 @@ static int CmdTearoff(const char *Cmd) {
|
||||
return handle_tearoff(¶ms, !silent);
|
||||
}
|
||||
|
||||
static int CmdBwmSetCap(const char *Cmd) {
|
||||
CLIParserContext *ctx;
|
||||
CLIParserInit(&ctx, "hw bwmsetcap",
|
||||
"Program the BWM fuel gauge (BQ27427) Design Capacity for the fitted cell.\n"
|
||||
"Run ONCE after fitting or replacing the battery. This triggers a gauge\n"
|
||||
"config-update; do not run it repeatedly, as that disrupts the Impedance\n"
|
||||
"Track learning cycle. PM5 only.",
|
||||
"hw bwmsetcap --> set design capacity to default 500 mAh\n"
|
||||
"hw bwmsetcap --cap 500 --> set design capacity to 500 mAh");
|
||||
|
||||
void *argtable[] = {
|
||||
arg_param_begin,
|
||||
arg_int0(NULL, "cap", "<mAh>", "design capacity in mAh (default 500)"),
|
||||
arg_param_end
|
||||
};
|
||||
CLIExecWithReturn(ctx, Cmd, argtable, true);
|
||||
int cap = arg_get_int_def(ctx, 1, 500);
|
||||
CLIParserFree(ctx);
|
||||
|
||||
if (cap <= 0 || cap > 32000) {
|
||||
PrintAndLogEx(WARNING, "capacity out of range: %d mAh", cap);
|
||||
return PM3_EINVARG;
|
||||
}
|
||||
|
||||
uint8_t payload[2] = { (uint8_t)(cap & 0xFF), (uint8_t)((cap >> 8) & 0xFF) };
|
||||
PrintAndLogEx(INFO, "Programming BWM gauge design capacity to " _YELLOW_("%d mAh") "...", cap);
|
||||
PrintAndLogEx(INFO, "Run this " _YELLOW_("once") "; then perform a full charge/discharge learning cycle.");
|
||||
|
||||
clearCommandBuffer();
|
||||
SendCommandNG(CMD_PM5_BWM_SET_CAP, payload, sizeof(payload));
|
||||
PacketResponseNG resp;
|
||||
if (WaitForResponseTimeout(CMD_PM5_BWM_SET_CAP, &resp, 5000) == false) {
|
||||
PrintAndLogEx(WARNING, "command timeout (is this a PM5 with a BWM fitted?)");
|
||||
return PM3_ETIMEOUT;
|
||||
}
|
||||
if (resp.status != PM3_SUCCESS) {
|
||||
PrintAndLogEx(FAILED, "gauge provisioning failed - check BWM present and gauge unsealed");
|
||||
return resp.status;
|
||||
}
|
||||
PrintAndLogEx(SUCCESS, "Design capacity programmed. `hw status` should now report sane capacity.");
|
||||
return PM3_SUCCESS;
|
||||
}
|
||||
|
||||
static int CmdTia(const char *Cmd) {
|
||||
CLIParserContext *ctx;
|
||||
CLIParserInit(&ctx, "hw tia",
|
||||
@@ -1965,6 +2008,7 @@ static command_t CommandTable[] = {
|
||||
{"setmux", CmdSetMux, IfPm3Present, "Set the ADC mux to a specific value"},
|
||||
{"standalone", CmdStandalone, IfPm3Present, "Start installed standalone mode on device"},
|
||||
{"tia", CmdTia, IfPm3Present, "Trigger a Timing Interval Acquisition to re-adjust the RealTimeCounter divider"},
|
||||
{"bwmsetcap", CmdBwmSetCap, IfPm3Present, "Set BWM fuel-gauge design capacity (PM5, run once after battery change)"},
|
||||
{"tune", CmdTune, IfPm3Lf, "Measure tuning of device antenna"},
|
||||
{"decay", CmdDecay, IfPm3Present, "Measure HF antenna decay after field-off"},
|
||||
{NULL, NULL, NULL, NULL}
|
||||
|
||||
Reference in new issue
Block a user