Issue #69 - Added missing specifications

Added missing specs, such as string encoding, RGB color space, and time as UTC.
Also slightly reformatted things like manufacture date and time to call out things like Year, Month, Date as separate bytes, which uses the same amount of space on the tag, but is easier to read.

Lastly, print temp and bed temp is represented as multiples of 5-degrees C, which lets us represent 0-1275C with just a single byte
This commit is contained in:
thekakester authored and GitHub committed 2025-06-15 12:19:47 -04:00
1 parent 191ad637ef
commit dbb0e42ac8
1 file changed
+32 -30
+32 -30
View File
@@ -88,22 +88,25 @@ NTAG216 tags have 888 bytes of usable memory.
### Memory Map - Open Tag Lite
This is designed to fit within 144 bytes (address 0x10-0x9F), which is for NTAG213, the smallest and cheapest variant of compatible tags.
All strings are UTF-8 unless specified otherwise.
All integers are unsigned, big endian, unless specified otherwise.
| Field | Data Type | Start Address | Size (bytes) | Usage | Example | Description |
|---------------------------|-----------|----------------|---------------|----------------|--------------------------------|-------------|
| Tag Format | String | 0x10 | 2 | Operational | `OT` | This is always "OT" for "Open Tag", this helps differentiate between the OpenTag and other formats. If a tag doesn't start with "OT", it is not OpenTag format. |
| Tag Version | Int | 0x12 | 2 | Operational | `1234` | RFID tag data format version to allow future compatibility in the event that the data format changes dramatically. Stored as an int with 3 implied decimal points. Eg `1000` -> version `1.000`. |
| Filament Manufacturer | String | 0x14 | 16 | Display-only | `"Polar Filament"` | String representation of filament manufacturer. 16 bytes is the max data length per-block. Longer names will be abbreviated or truncated. |
| Tag Version | Int | 0x12 | 2 | Operational | `1234` | RFID tag data format version to allow future compatibility in the event that the data format changes dramatically. Stored as an int with 3 implied decimal points. Eg `1000` → version `1.000`. |
| Filament Manufacturer | String | 0x14 | 16 | Display-only | `"Polar Filament"` | String representation of filament manufacturer. 16 bytes is the max data length per block. Longer names will be abbreviated or truncated. |
| Base Material Name | String | 0x24 | 5 | Display-only | `"PLA"`, `"PETG"`, `"PCTFE"` | Material name in plain text, excluding any modifiers. |
| Material Modifiers | String | 0x29 | 5 | Display-only | `"CF"`, `"HF"`, `"Pro"`, `"Silk"` | Material subcategory or modifier in plain text to give more context to the base material. Long modifiers may need to be abbreviated. |
| Color Name | String | 0x2E | 32 | Display-only | `"Blue"`, `"Electric Watermelon"` | Color in plain text. |
| Diameter (Target) | Int | 0x4E | 2 | Operational | `1750`, `2850` | Filament diameter (target) in µm (micrometers). Eg `1750` -> `1.750mm`. |
| Color RGB | Int[1+1+1]| 0xC4 | 3 | Display-only | `[255, 166, 77]` | Color stored as 3 separate 1-byte integers for red, green, and blue, in the sRGB color space. This is used for UI previews or rendering. |
| Diameter (Target) | Int | 0x4E | 2 | Operational | `1750`, `2850` | Filament diameter (target) in µm (micrometers). Eg `1750` → `1.750mm`. |
| Weight (Nominal, grams) | Int | 0x50 | 2 | Operational | `1000`, `5000`, `750` | Filament weight in grams, excluding spool weight. This is the TARGET weight (e.g., 1kg). Actual measured weight is stored in a different field. |
| Print Temp (C) | Int | 0x52 | 2 | Operational | `210`, `240` | The recommended print temperature in degrees Celsius. |
| Bed Temp (C) | Int | 0x54 | 2 | Operational | `60`, `80` | The recommended bed temperature in degrees Celsius. |
| Density | Int | 0x56 | 2 | Operational | `1240`, `3900` | Filament density in µg (micrograms) per cubic centimeter. Eg `1240` -> `1.240g/cm³`. |
| Print Temp (×5 °C) | Int | 0x52 | 1 | Operational | `42` | Recommended print temperature in degrees Celsius, stored as 5× the actual value. For example, `42` represents `210°C`. |
| Bed Temp (×5 °C) | Int | 0x53 | 1 | Operational | `12`, `16` | Recommended bed temperature in degrees Celsius, stored as 5× the actual value. For example, `12` = `60°C`. |
| Density | Int | 0x56 | 2 | Operational | `1240`, `3900` | Filament density in µg (micrograms) per cubic centimeter. Eg `1240` → `1.240g/cm³`. |
| RESERVED | — | 0x58–0x6C | — | — | — | Reserved for future use. This goes up to the memory limit of NTAG213. |
| Online Data URL | String | 0x6D | 32 | Operational | `pfil.us?i=8078-RQSR` | URL to access online JSON additional parameters. Formatted without `https` to save space. |
| Online Data URL | String (ASCII) | 0x6D | 32 | Operational | `pfil.us?i=8078-RQSR` | URL to access online JSON additional parameters. Formatted without `https` to save space. |
### Memory Map - Extended Data
@@ -112,29 +115,28 @@ This memory address starts at address 144, which is just outside the range of NT
We should do our best to remain within memory address, which has a max address of 0x20B.
| Field | Data Type | Start Address | Size (bytes) | Usage | Example | Description |
|----------------------------------|-----------|---------------|---------------|--------------|--------------------------|-------------|
| Serial Number / Batch ID | String | 0xA0 | 16 | Operational | `1234-ABCD`, `2024-01-23-1234` | An identifier to represent a serial number or batch number from manufacturing. Stored as a string, and this format will vary from manufacturer to manufacturer. |
| Manufacture Date | Int | 0xB0 | 4 | Operational | `20240123` | Date code in YYYYMMDD format, stored as a 32-bit integer. |
| Manufacture Time | Int | 0xB4 | 3 | Operational | `103000`, `152301` | 24-hour time code in HHMMSS format (Hour, Minute, Second), specifying UTC. |
| Spool Core Diameter (mm) | Int | 0xB7 | 1 | Operational | `100`, `80` | The diameter of the spool core. Used to estimate remaining filament based on encoder behavior. |
| MFI Temp (°C) | Int | 0xB8 | 1 | Operational | `210` | Temperature in degrees Celsius at which the melt flow index was measured. |
| MFI Load (×100g) | Int | 0xB9 | 1 | Operational | `216` | Load used in the MFI test, stored as centigrams. For 2.16kg, store `216`. |
| MFI Value (×10 g/10min) | Int | 0xBA | 1 | Operational | `63` | Melt Flow Index value ×10. For example, 6.3 g/10min is stored as `63`. |
| Tolerance (Measured) | Int | 0xBB | 1 | Operational | `20`, `55` | Actual measured tolerance in µm (micrometers). Unique per spool. If not recorded, leave as 0xFF. |
| Empty Spool Weight (g) | Int | 0xBC | 2 | Operational | `105` | Empty spool weight in grams, used to estimate remaining filament. |
| Filament Weight (Measured) | Int | 0xBE | 2 | Operational | `1002` | Measured filament weight in grams, excluding the spool. Not the target weight. |
| Filament Length (Measured) | Int | 0xC0 | 2 | Operational | `336` | Measured filament length in meters, unique per spool. |
| TD (Transmission Distance) | Int | 0xC2 | 2 | Operational | `2540` | Transmission Distance in µm. The thickness where no light passes. See HueForge. |
| Color Hex | Int | 0xC4 | 3 | Operational | `0xffa64d` | RGB color in 3-byte hex format (0xRRGGBB). Used for UI or preview. |
| Max Dry Temp (°C) | Int | 0xC7 | 1 | Operational | `50`, `55` | Maximum drying temperature in °C. Drying above this temp may damage filament. |
| Dry Time (Hours) | Int | 0xC8 | 1 | Operational | `4`, `8`, `12` | Recommended drying time in whole hours. |
| Min Print Temp (°C) | Int | 0xC9 | 1 | Operational | `190` | Minimum recommended nozzle temperature for printing. |
| Max Print Temp (°C) | Int | 0xCA | 1 | Operational | `225` | Maximum recommended nozzle temperature for printing. |
| Volumetric Speed Min (×10 mm³/s) | Int | 0xCB | 1 | Operational | `20` | Minimum recommended volumetric speed, stored as mm³/s ×10. |
| Volumetric Speed Max (×10 mm³/s) | Int | 0xCC | 1 | Operational | `120` | Maximum safe volumetric speed, stored as mm³/s ×10. |
| Volumetric Speed Recommended | Int | 0xCD | 1 | Operational | `80` | Recommended default volumetric speed, stored as mm³/s ×10. |
| RESERVED | — | 0xCE–0x1FF | — | — | — | Reserved for future use, this goes up to the memory limit of NTAG215. |
| Field | Data Type | Start Address | Size (bytes) | Usage | Example | Description |
|----------------------------------|---------------|---------------|---------------|--------------|--------------------------|-------------|
| Serial Number / Batch ID | String | 0xA0 | 16 | Display-Only | `1234-ABCD`, `2024-01-23-1234` | Identifier for a spool batch or serial number. Format varies from manufacturer to manufacturer |
| Manufacture Date (Y, M, D) | Int[2+1+1] | 0xB0 | 4 | Display-Only | `[2024, 01, 23]` | Stored as 2 bytes for year, then 1 byte for month and 1 byte for day. |
| Manufacture Time (H, M, S, UTC) | Int[1+1+1] | 0xB4 | 3 | Display-Only | `[10, 30, 45]` | Stored as 1 byte each for hour, minute, and second in 24-hour UTC. |
| Spool Core Diameter (mm) | Int | 0xB7 | 1 | Operational | `100`, `80` | Core diameter in mm. |
| MFI Temp (°C) | Int | 0xB8 | 1 | Operational | `210` | MFI test temperature. |
| MFI Load (×100g) | Int | 0xB9 | 1 | Operational | `216` | MFI test load (e.g. 216 = 2.16kg). |
| MFI Value (×10 g/10min) | Int | 0xBA | 1 | Operational | `63` | MFI ×10 value. |
| Tolerance (Measured) | Int | 0xBB | 1 | Operational | `20`, `55` | Measured tolerance in µm. |
| Empty Spool Weight (g) | Int | 0xBC | 2 | Operational | `105` | Weight of empty spool. |
| Filament Weight (Measured) | Int | 0xBE | 2 | Operational | `1002` | Weight of filament only. |
| Filament Length (Measured) | Int | 0xC0 | 2 | Operational | `336` | Length in meters. |
| TD (Transmission Distance) | Int | 0xC2 | 2 | Operational | `2540` | Opaque thickness in µm. |
| Max Dry Temp (°C) | Int | 0xC4 | 1 | Operational | `50`, `55` | Max safe drying temp. |
| Dry Time (Hours) | Int | 0xC5 | 1 | Operational | `4`, `8`, `12` | Recommended drying time. |
| Min Print Temp (°C) | Int | 0xC6 | 1 | Operational | `190` | Minimum nozzle temp. |
| Max Print Temp (°C) | Int | 0xC7 | 1 | Operational | `225` | Maximum nozzle temp. |
| Volumetric Speed Min (×10 mm³/s)| Int | 0xC8 | 1 | Operational | `20` | Min speed recommendation. |
| Volumetric Speed Max (×10 mm³/s)| Int | 0xC9 | 1 | Operational | `120` | Max safe speed. |
| Volumetric Speed Recommended | Int | 0xCA | 1 | Operational | `80` | Default recommended speed. |
| RESERVED | — | 0xCB–0x1FF | — | — | — | Reserved for future use. |
### Web API Standard