<?xml version="1.0" encoding="utf-8"?>
<?xml-stylesheet type="text/xsl" href="../XSLT/decoder.xsl"?>
<!-- Copyright (C) JMRI 2022 All rights reserved -->
<!-- -->
<!-- JMRI is free software; you can redistribute it and/or modify it under -->
<!-- the terms of version 2 of the GNU General Public License as published -->
<!-- by the Free Software Foundation. See the "COPYING" file for a copy -->
<!-- of this license. -->
<!-- -->
<!-- JMRI is distributed in the hope that it will be useful, but WITHOUT -->
<!-- ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or -->
<!-- FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License -->
<!-- for more details. -->
<variables xmlns:xi="http://www.w3.org/2001/XInclude" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="http://jmri.org/xml/schema/decoder-4-15-2.xsd">
<copyright xmlns="http://docbook.org/ns/docbook">
<year>2022</year>
<holder>JMRI</holder>
</copyright>
<authorgroup xmlns="http://docbook.org/ns/docbook">
<author>
<personname>
<firstname>Ulrich</firstname>
<surname>Gerlach</surname>
</personname>
</author>
</authorgroup>
<revhistory xmlns="http://docbook.org/ns/docbook">
<revision>
<revnumber>1</revnumber>
<date>2022-11-11</date>
<authorinitials>UG</authorinitials>
<revremark>Initial version for Piko SmartDecoder XP5.1</revremark>
</revision>
<revision>
<revnumber>2</revnumber>
<date>2023-12-03</date>
<authorinitials>UG</authorinitials>
<revremark>Add English translations</revremark>
</revision>
<revision>
<revnumber>3</revnumber>
<date>2025-02-13</date>
<authorinitials>UG</authorinitials>
<revremark>Add CV250 bit3 and bit4</revremark>
</revision>
<revision>
<revnumber>4</revnumber>
<date>2025-06-12</date>
<authorinitials>UG</authorinitials>
<revremark>Add CV250 bit5</revremark>
</revision>
</revhistory>
<variable item="Motor Management 1" CV="240" default="16">
<decVal max="32"/>
<label>Measurement gaps (CV 240)</label>
<label xml:lang="de">Messlücke (CV 240)</label>
<tooltip>Distance measurement in measuring gap, measurement BEMF motor offset</tooltip>
<tooltip xml:lang="de">Abstand Messung in Messlücke, Messung BEMF Motor Offset (0-32)</tooltip>
</variable>
<variable item="Motor Management 2" CV="241" default="200">
<decVal/>
<label>Control factor DC digital (CV 241)</label>
<label xml:lang="de">Regelfaktor DC digital (CV 241)</label>
<tooltip>Proportional increasing Limit DC digital</tooltip>
<tooltip xml:lang="de">Proportional steigend Limit DC digital (0-255)</tooltip>
</variable>
<variable item="Motor Management 3" CV="242" default="40">
<decVal/>
<label>Control factor AC analog (CV 242)</label>
<label xml:lang="de">Regelfaktor AC analog (CV 242)</label>
<tooltip>Proportional increasing Limit AC analog</tooltip>
<tooltip xml:lang="de">Proportional steigend Limit AC analog (0-255)</tooltip>
</variable>
<variable item="Motor Management 4" CV="243" default="0">
<decVal max="50"/>
<label>Minimum control package width (CV 243)</label>
<label xml:lang="de">Minimale Steuerpaketbreite (CV 243)</label>
<tooltip>Offset controller, control</tooltip>
<tooltip xml:lang="de">Offset Regler, Ansteuerung (0-255)</tooltip>
</variable>
<variable item="Motor Management 5" CV="244" default="200">
<decVal/>
<label>Control factor DC digital (CV 244)</label>
<label xml:lang="de">Regelfaktor DC digital (CV 244)</label>
<tooltip>Proportional decreasing Limit DC digital</tooltip>
<tooltip xml:lang="de">Proportional fallend Limit DC digital (0-255)</tooltip>
</variable>
<variable item="Motor Management 6" CV="245" default="220">
<decVal/>
<label>Control factor AC analog (CV 245)</label>
<label xml:lang="de">Regelfaktor AC analog (CV 245)</label>
<tooltip>Proportional decreasing Limit AC analog</tooltip>
<tooltip xml:lang="de">Proportional fallend Limit AC analog (0-255)</tooltip>
</variable>
<variable item="Motor Management 7" CV="246" default="0">
<decVal/>
<label>Rapid reduction of the control current (CV 246)</label>
<label xml:lang="de">Schnelles Absenken des Steuerstroms (CV 246)</label>
<tooltip>Fast lowering of the control current</tooltip>
<tooltip xml:lang="de">Differenz Schnelles Absenken des Steuerstroms (0-255)</tooltip>
</variable>
<variable item="Motor Management 8" CV="247" default="0">
<decVal/>
<label>Damping the upward swing (CV 247)</label>
<label xml:lang="de">Dämpfen des Aufschwingens (CV 247)</label>
<tooltip>Damping of the upswing during spinning</tooltip>
<tooltip xml:lang="de">Dämpfen des Aufschwingens beim Schleudern (0-255)</tooltip>
</variable>
<variable item="Motor Management 9" CV="250" default="0">
<decVal max="31"/>
<label>Extended central station compatibility (CV 250)</label>
<label xml:lang="de">Erweiterte Zentralen Kompatibilität (CV 250)</label>
<tooltip>Enhanced Central Station Compatibility bit 0 - 4</tooltip>
<tooltip xml:lang="de">Erweiterte Zentralen Kompatibilität Bit 0 bis Bit 4 (0-31)</tooltip>
</variable>
<variable item="Motor Management 9 Bit 0" CV="250" default="0" mask="XXXXXXXV">
<xi:include href="http://jmri.org/xml/decoders/parts/enum-NoYes.xml"/>
<label>DCC Legacy Registermodus</label>
<label xml:lang="de">Funktionen bleiben gespeichert</label>
<tooltip>DCC Legacy Command Register Mode with Paged Mode for NCE Power Cab (0 / 1)</tooltip>
<tooltip xml:lang="de">Funktionen bleiben gespeichert, auch wenn die verwendete Zentrale die Adressierung abschaltet oder einen RESET sendet (0 / 1)</tooltip>
</variable>
<variable item="Motor Management 9 Bit 1" CV="250" default="0" mask="XXXXXXVX">
<xi:include href="http://jmri.org/xml/decoders/parts/enum-NoYes.xml"/>
<label>DCC 28 Stop Command</label>
<label xml:lang="de">DCC 28 Stopp Befehl</label>
<tooltip>DCC28 stop commands are also accepted in DCC128 mode for NCE Power Cab (0 / 1)</tooltip>
<tooltip xml:lang="de">DCC28 Stopp Befehle werden auch im DCC128 Mode akzeptiert (0 / 1)</tooltip>
</variable>
<variable item="Motor Management 9 Bit 2" CV="250" default="0" mask="XXXXXVXX">
<xi:include href="http://jmri.org/xml/decoders/parts/enum-NoYes.xml"/>
<label>DCC Legacy Registermodus</label>
<label xml:lang="de">Programmiergleisbefehl ohne Wiederholung</label>
<tooltip>Programming track accept commands even without repetition (0 / 1)</tooltip>
<tooltip xml:lang="de">Programmiergleis Befehle auch ohne Wiederholung akzeptieren (0 / 1)</tooltip>
</variable>
<variable item="Motor Management 9 Bit 3" CV="250" default="0" mask="XXXXVXXX">
<xi:include href="http://jmri.org/xml/decoders/parts/enum-NoYes.xml"/>
<label>Function Reset</label>
<label xml:lang="de">Funktionen bei Reset</label>
<tooltip>Do not reset functions after DCC reset (Activate in case of problems with Z21) (0 / 1)</tooltip>
<tooltip xml:lang="de">Funktionen nach DCC-Reset nicht zurücksetzen (Aktivieren bei Problemen mit Z21) (0 / 1)</tooltip>
</variable>
<variable item="Motor Management 9 Bit 4" CV="250" default="0" mask="XXXVXXXX">
<xi:include href="http://jmri.org/xml/decoders/parts/enum-NoYes.xml"/>
<label>Light buffering analogue mode</label>
<label xml:lang="de">Lichtpufferung Analog Modus</label>
<tooltip>(0 / 1)</tooltip>
<tooltip xml:lang="de">(0 / 1)</tooltip>
</variable>
<variable item="Motor Management 9 Bit 5" CV="250" default="0" mask="XXVXXXXX">
<xi:include href="http://jmri.org/xml/decoders/parts/enum-NoYes.xml"/>
<label>Linearisation 28 speed settings</label>
<label xml:lang="de">Linearisierung 28 Fahrstufen</label>
<tooltip>(0 / 1)</tooltip>
<tooltip xml:lang="de">(0 / 1)</tooltip>
</variable>
</variables>