Files
JIMRI/help/en/package/jmri/jmrix/loconet/pm4/PM4Frame.shtml
T
2026-06-17 14:00:51 +02:00

68 lines
3.1 KiB
Plaintext

<!DOCTYPE html>
<html lang="en">
<head>
<meta name="generator" content="HTML Tidy for HTML5 for Apple macOS version 5.8.0">
<title>JMRI: Configure Digitrax PM4</title>
<meta name="author" content="Bob Jacobsen">
<meta name="keywords" content="JMRI help configure loconet PM4">
<!--#include virtual="/help/en/parts/Style.shtml" -->
</head>
<body>
<!--#include virtual="/help/en/parts/Header.shtml" -->
<div id="mBody">
<div id="mainContent" class="no-sidebar">
<a href="PM4xConfigTool.png"><img src="PM4xConfigTool.png" style="float:right; margin: 5px;"
alt="PM4x Configuration Tool Screen Capture"></a>
<h1>Configure Digitrax PM4x</h1>
<p>The JMRI PM4x programming tool lets you configure the internal options of a PM4 or PM42
directly from your computer.</p>
<p>To open this tool from the JMRI start page select the LocoNet tab then find the tool on
the drop down list.</p>
<p>To use it, you put the address of a PM4x board in the text field and click "Read from
PM4x". The tool will read back the current state of the various options, and set the check
boxes to correspond to their current values.</p>
<p>You can then, if you wish, change the checkboxes and click "Write to PM4x" to make your
changes permanent.</p>
<p>The tool relies upon each PM4x board to have a unique "Board ID" (Board Address) in order
to configure each device individually. While it is possible to change the Board ID number
using JMRI, it cannot be done using this tool due to limitations of the PM4x design. Instead,
follow the instructions found <a href=
"../../../../../html/hardware/loconet/Digitrax.shtml#deviceBoardId">here</a>, but you must
consult the appropriate PM4x manual and modify the JMRI-based process to suit the PM4x
device's buttons, button press time, and lamp flashes.</p>
<h2>Limitations</h2>
<ul>
<li>This tool is able to access PM4x boards with addresses between 1 and 256. Users are
advised to avoid using the factory default board address (board address 1) as it will be
difficult to program new boards with unique data if any in-service board is using the
factory default board address.</li>
<li>Because of the way the PM4x board works, this tool can't change the basic address of
the unit. The PM4x documentation describes how to change the board address. It is possible
to change the Board ID number using JMRI by following the instructions found <a href=
"../../../../../html/hardware/loconet/Digitrax.shtml#deviceBoardId">here</a>. Note that it
is necessary to consult the appropriate PM4x manual and modify the JMRI-based process shown
at the link above to suit the PM4x's buttons, button press time, and lamp flashes.
</li>
</ul>
<h2>See Also</h2>
<p>Documentation for the PM4 and PM42 can be found at the <a href=
"http://www.digitrax.com">Digitrax Web Site.</a></p>
<!--#include virtual="/help/en/parts/Footer.shtml" -->
</div>
</div>
<!-- closes #mBody-->
<script src="/js/help.js"></script>
</body>
</html>