Files
JIMRI/help/en/html/hardware/loconet/DCS52.shtml
T
2026-06-17 14:00:51 +02:00

479 lines
21 KiB
Plaintext

<!DOCTYPE html>
<html lang="en">
<head>
<meta name="generator" content="HTML Tidy for HTML5 for Apple macOS version 5.8.0">
<title>JMRI Hardware Support - Connecting to a Digitrax DCS52</title>
<meta name="author" content="Bob Jacobsen">
<meta name="author" content="B. Milhaupt">
<meta name="keywords" content=
"Digitrax DCS Command Station DCS52 java model railroad JMRI install windows">
<!--#include virtual="/help/en/parts/Style.shtml" -->
<style>
.ctr {
text-align: center;
}
table {
border: 3px solid;
}
th {
border: 1px solid;
}
td {
border: 1px solid;
}
</style>
</head>
<body>
<!--#include virtual="/help/en/parts/Header.shtml" -->
<div id="mBody">
<!--#include virtual="Sidebar.shtml" -->
<div id="mainContent">
<h1>Hardware Support: Digitrax DCS52</h1>
<div class="toc">
<ul>
<li>
<a href="#ConnectingDCS52">Connecting JMRI to a Digitrax DCS52</a>
<ul>
<li>
<a href="#ChooseAMethod">Choosing the configuration method</a>
<ul>
<li>
<a href="#Dcs52Standalone">DCS52 USB interface as a stand-alone decoder
programmer</a>
<ul>
<li>
<a href="#Dcs52SetupStandAlone">Setup for the DCS52 acting as a standalone
programmer</a>
</li>
<li>
<a href="#Dcs52StandaloneHints">DCS52 USB Interface in Standalone
Programming Mode Usage Hints</a>
</li>
</ul>
</li>
<li>
<a href="#Dcs52GeneralCmdStn">DCS52 USB interface as a LocoNet Interface</a>
<ul>
<li>
<a href="#Dcs52SetupUsbInterface">Setup for the DCS52 acting as a LocoNet
interface</a>
</li>
</ul>
</li>
<li>
<a href="#Dcs52ViaAdapter">DCS52 connected via some other LocoNet Interface</a>
</li>
</ul>
</li>
</ul>
</li>
<li>
<a href="#Dcs52Drivers">DCS52 Drivers</a>
</li>
<li>
<a href="#SeeAlso">See Also</a>
</li>
</ul>
</div>
<h1 id="ConnectingDCS52">Hardware Support: Connecting to a Digitrax DCS52</h1>
<p>JMRI may be connected to the Digitrax DCS52 in any of a wide variety of ways. Since the
DCS52 has a built-in USB interface, it is possible to simply plug a USB cable into the
computer and the DCS52, and configure JMRI to suit this connection. It is also possible to
use another LocoNet interface device, such as a LocoBuffer-USB, Digitrax PR3, or Digitrax
PR4, to interface a computer to LocoNet, and connect that LocoNet to the DCS52. JMRI does not
prefer any one connection method over any other method. Choose one which is suitable for your
needs.</p>
<p>If a USB cable is used to connect the JMRI computer to the DCS52's USB connection, JMRI
may be configured in one of two modes. If the computer will only be used for decoder
programming, and JMRI will not need access to LocoNet features other than the DCS52
"programming track", then JMRI may be configured to use a "connection" where the DCS52 USB
interface is placed into a mode where it acts as a standalone decoder programmer. In this
mode, JMRI will access the DCS52 dedicated programming track connections. This mimics the
"standalone programmer" configuration which the PR2 provides, and which the PR3 and PR4 can
support.</p>
<p>Alternately, when JMRI will be used to access LocoNet resources which go beyond simply the
DCS52 programming track, then JMRI should be configured to act as a general-purpose LocoNet
interface. The JMRI "connection" should be configured so that the "command station" type
specifies the type of command station which is being used.</p>
<p>If, instead of using the DCS52's integrated USB port, you plan to connect your computer to
the DCS52 using a LocoNet adapter device, follow the instructions found <a href=
"Digitrax.shtml#ConnectingAdapter">here</a>.</p>
<p>The table below summarizes these possibilities.</p>
<table>
<tr>
<th rowspan="2">Connection Type</th>
<th rowspan="2">Usage</th>
<th colspan="2">Settings in JMRI Connection Profile</th>
<th rowspan="2">Instructions</th>
<th rowspan="2">Available JMRI Capabilities</th>
</tr>
<tr>
<th>System Connection</th>
<th class=".ctr">JMRI Command Station Type</th>
</tr>
<tr class="ctr">
<td rowspan="9">USB cable from computer to DCS52 USB connector</td>
<td rowspan="2">Decoder Programming</td>
<td rowspan="2">"<em>DCS52 USB Interface</em>"</td>
<td rowspan="2">"<em>DCS52 Standalone Programmer</em>"</td>
<td rowspan="2">
<a href="#Dcs52Standalone">Configuration help</a>
</td>
<td style="text-align: left">Program decoder CVs on the dedicated programming track</td>
</tr>
<tr>
<td>Operate one loco on the dedicated programming track</td>
</tr>
<tr class="ctr">
<td rowspan="7">LocoNet Interface, Decoder Programming</td>
<td rowspan="7">"<em>DCS52 USB Interface</em>"</td>
<td rowspan="7">"<em>DCS52 (Zephyr Express Command Station)</em>"</td>
<td rowspan="7">
<a href="#Dcs52GeneralCmdStn">Configuration help</a>
</td>
<td style="text-align: left">Program decoder CVs on the dedicated programming track
and/or the main track</td>
</tr>
<tr>
<td>Control one or more locos on the main track</td>
</tr>
<tr>
<td>Control and monitor LocoNet-connected Switches, Sensors, and Transponding</td>
</tr>
<tr>
<td>Configure some LocoNet devices</td>
</tr>
<tr>
<td>Control or monitor the LocoNet Fast Clock</td>
</tr>
<tr>
<td>Update firmware on some LocoNet devices</td>
</tr>
<tr>
<td>etc.</td>
</tr>
<tr class="ctr">
<td rowspan="7">LocoNet Interface, Decoder Programming</td>
<td rowspan="7">Computer Connection to something other than the DCS52 USB connector</td>
<td rowspan="7">Something other than "DCS52 USB Interface"</td>
<td rowspan="7">"<em>DCS52 (Zephyr Express Command Station)</em>"</td>
<td rowspan="7">
<a href="#Dcs52ViaAdapter">Configuration help</a>
</td>
<td style="text-align: left">Program decoder CVs on the dedicated programming track</td>
</tr>
<tr>
<td>Control one or more locos on the main track</td>
</tr>
<tr>
<td>Control and monitor LocoNet-connected Switches, Sensors, and Transponding</td>
</tr>
<tr>
<td>Configure some LocoNet devices</td>
</tr>
<tr>
<td>Control or monitor the LocoNet Fast Clock</td>
</tr>
<tr>
<td>Update firmware on some LocoNet devices</td>
</tr>
<tr>
<td>etc.</td>
</tr>
</table>
<p>Note that it is possible to use the DCS52 in a "booster" mode, and rely upon some other
command station. If this configuration is used, the "command station" specified for the JMRI
connection should match the device which is actually acting as the command station.</p>
<h2 id="ChooseAMethod">Choosing a configuration method</h2>
<p>When setting up a JMRI "connection profile", which "command station" should you use when
configuring JMRI? That depends on what you intend to do with JMRI.</p>
<ul>
<li>If you will <em>only</em> use JMRI to program decoders on the dedicated programming
track, then configuring the connection for the "command station" type of "DCS52 Standalone
Programmer" mode is a good choice. In this mode, JMRI will be able to read and write
decoder CV values. In this mode, you may also use a JMRI throttle to select and control the
locomotive on the dedicated programming track, subject to the ability of the DCS52 to
supply sufficient current to the decoder. JMRI will <em>not</em> be able to access LocoNet
peripherals and JMRI throttles will <em>not</em> be able to control decoders via the "main
track".</li>
<li>
<p>If you wish JMRI to be able to control decoders via the DCS52 main track outputs, and
access LocoNet devices, then configuring the connection for the "command station" type of
"DCS52 Standalone Programmer" mode is a good choice. In this mode, JMRI is able to
control decoders connected via the main track outputs and access LocoNet devices. JMRI
may also perform decoder programming via the dedicated programming track, but JMRI
throttles will <em>not</em> be able to run decoders which are on the dedicated
programming track.</p>
</li>
<li>If you think that both modes may be useful to you, you should consider setting up
<em>two</em> configuration profiles. Then, when you start JMRI, you may select the
configuration profile which suits the way you want to use JMRI. And to switch to the other
mode, you may simply quit JMRI and re-start it, and select the other profile, so that you
may perform the other type of work.</li>
</ul>
<h3 id="Dcs52Standalone">DCS52 USB interface as a stand-alone decoder programmer</h3>
<p><img src="images/DCS52StandaloneProgrammerConnections.png" alt=
"Typical connections for DCS52 for use as standalone programmer" width="300">
</p>
<p>When the DCS52 USB interface is configured to act as a programmer, it acts upon the
dedicated programming track via the "programming track" connections on the DCS52. When JMRI
is properly configured, JMRI can use the DCS52 programming track to access decoder CVs when
the decoder is connected to the programming track.</p>
<p>This JMRI configuration may also be used to download sound information into Digitrax sound
decoders and, within its limited current capability, run one locomotive to test it. When used
with Digitrax SFX decoders, "neutral mode" allows you to vary the speed without the motor
moving the decoder, so you can hear how the locomotive sound reacts to varying speeds.</p>
<p>In this mode of operations, JMRI will not have access to LocoNet-based devices.</p>
<h4 id="Dcs52SetupStandAlone">Setup for the DCS52 acting as a standalone programmer</h4>
<p>To use the DCS52 programming track, connect the DCS52 to its power supply and connect a
dedicated piece of track which you'll use as the programming track to the DCS52 "programming
track" terminals. Finally, connect a USB cable between the DCS52 and your computer.</p>
<p>To set up JMRI to use the DCS52 via the dedicated decoder programming track mode:</p>
<ul>
<li>Start the program.</li>
<li>Open the Preferences window from the Edit menu and configure the connection by:
<ul>
<li>For the "<strong>System Connection</strong>" setting, select "DCS52 USB
Interface"</li>
<li>Under "<strong>Serial Port</strong>", select the serial port that's connected to
the DCS52</li>
<li>In the "<strong>Command station type</strong>" option, select the type of command
station you've got on your LocoNet. Typically, this will be "<code><strong>DCS52 USB
Interface as standalone programmer</strong></code>".</li>
<li>In the advanced settings, the speed will be fixed at 57,600 baud.</li>
<li>In the advanced settings, the "Flow Control" option defaults to "Use Hardware Flow
Control", which is the preferred setting for the DCS52. You should try that first, as
it is the most reliable mode. Only if you can't reliably program decoders using that
choice, and only after checking that you're using the right port, should you select
"None" for this preference and try again.</li>
</ul>
</li>
<li>Click Save at the bottom of the preferences window, quit the program and restart.</li>
</ul>
<p>The "connection" preferences should look similar to this image:</p>
<img src="images/DCS52StandConnProfile.png" alt=
"Sample configuration profile with DCS52 USB interface as a standalone programmer" width=
"500">
<h4 id="Dcs52StandaloneHints">DCS52 USB Interface in Standalone Programming Mode Usage
Hints</h4>
<ul>
<li>You can use a JMRI throttle to control the locomotive connected to the DCS52 Programmer
track. Use the JMRI Power Control or the "Power" menu item on the Throttle's menu bar to
turn on track power, and then you can operate the locomotive normally via a JMRI
throttle.</li>
<li>The DCS52 can only provide very limited current to the programming track, so Digitrax
has built a "neutral mode" into their sound decoders. When JMRI and the DCS52 is running a
Digitrax sound decoder, the motor is disconnected to reduce the current load. You can still
ramp the speed up and down with the throttle and listen to how the sound responds, but the
motor won't move the locomotive.
<ul>
<li>To implement that "neutral mode" described above, the DCS52 automatically writes
CV128 to 0 or 1. This happens when a JMRI throttle is used to run the locomotive on the
DCS52 programming track, and there's nothing JMRI can do to prevent it. Unfortunately,
this can interfere with the CV programming on some non-Digitrax decoders. For example,
it will set the "Master Volume" CV128 on some SoundTraxx decoders to a very low
volume.</li>
<li>If you are working with a decoder that uses CV128 for something, you should either
not use a JMRI throttle to run the locomotive on the DCS52 programming track, or
remember to rewrite CV128 with the right value just before removing the locomotive from
the track.</li>
</ul>
</li>
<li>Other decoders, including decoders from other manufacturers, may draw enough motor
current to trip the DCS52 internal circuit breakers. This will cause JMRI to mark track
power as "off". Just wait a couple seconds and turn the track power back on to
recover.</li>
<li>If the DCS52 is in its "Decoder CV programming" mode and JMRI is used to access decoder
CVs, then the DCS52 display may show programming-related information that is not strictly
accurate. This is because the DCS52 cannot easily discriminate between CV accesses made via
its keypad and CV accesses made via other sources.</li>
<li>It is possible run trains via the DCS52 controls and/or LocoNet-based throttles when
JMRI is programming a decoder on the DCS52 programming track.</li>
</ul>
<h3 id="Dcs52GeneralCmdStn">DCS52 USB interface as a LocoNet Interface</h3>
<p><img src="images/DCS52LocoNetInterfaceConnections.png" alt=
"Typical connections for DCS52 acting as a LocoNet interface" width="300">
</p>
<p>When acting as an interface, the DCS52 USB connection allows JMRI to interact with devices
connected to LocoNet. This includes programming decoders on a programming track attached to a
LocoNet command station. Where the LocoNet command station supports "programming on the
main", JMRI is able to make use of that feature.</p>
<h4 id="Dcs52SetupUsbInterface">Setup for the DCS52 acting as a LocoNet interface</h4>
<p>To use the DCS52 USB connection as a LocoNet interface, connect a LocoNet cable to a
LocoNet connector on the DCS52. Connect an appropriate power supply to the DCS52, per the
Digitrax instructions for the DCS52. The DCS52 USB interface will not be able to communicate
with LocoNet unless the DCS52 is properly powered. Finally, connect an appropriate USB cable
between the DCS52 USB connector and your computer.</p>
<p>To set up a JMRI application to use the DCS52 as an interface to a LocoNet which includes
a LocoNet command station:</p>
<ul>
<li>Start the program.</li>
<li>Open the Preferences window from the Edit menu and configure the connection by:
<ul>
<li>For the "<strong>System Connection</strong>" setting, select "DCS52 USB
Interface"</li>
<li>Under "<strong>Serial Port</strong>", select the serial port that's connected to
the DCS52</li>
<li>In the "<strong>Command station type</strong>" option, select the type of command
station you've got on your LocoNet. Typically, this will be "<code><strong>DCS52
(Zephyr Express command station)</strong></code>", but, if you have configured your
DCS52 to act only as a booster, you should select the command station option which
matches the active command station.</li>
<li>In the advanced settings, the speed will be fixed at 57,600 baud.</li>
<li>In the advanced settings, the "Flow Control" option defaults to "Use Hardware Flow
Control", which is the preferred setting for the DCS52. You should try that first, as
it is the most reliable mode. Only if you can't reliably program decoders using that
choice, and only after checking that you're using the right port, should you select
"None" for this preference and try again.</li>
</ul>
</li>
<li>Click Save at the bottom of the preferences window, quit the program and restart.</li>
</ul>
<p>The "Connection" preferences should look similar to this image:</p>
<img src="images/DCS52LocoNetInterfaceConnProfile.png" alt=
"Sample configuration profile with DCS52 USB interface as a LocoNet interface" width="500">
<h3 id="Dcs52ViaAdapter">DCS52 connected via some other LocoNet Interface</h3>
<p><img src="images/DCS52LocoNetInterfaceViaAdapter.png" alt=
"Typical connections for DCS52 when connected to computer via a LocoNet Interface Adapter"
width="300">
</p>
<p>JMRI may connect to the LocoNet via a LocoNet interface other than the DCS52 USB
connector. When connected in this fashion, <a href="Digitrax.shtml#ConnectingAdapter">these
general instructions</a>, or, where available, the JMRI documentation associated with the
LocoNet interface which is being used.</p>
<h1 id="Dcs52Drivers">DCS52 Drivers</h1>
The DCS52 USB interface needs to have a driver installed when used with any Microsoft Windows
Operating System. See the Digitrax <a href=
"https://www.digitrax.com/downloads/">"Downloads"</a> page for drivers. At the time this help
page was written, Digitrax provides Windows drivers for the PR3 device. Those drivers are
suitable for use with the DCS52 USB interface. Make sure to follow any instructions,
particularly any instructions about the order of installing the drivers and plugging in the
device.
<p>You don't need to install a separate driver when using current versions of MacOS or
Linux.</p>
<h1 id="SeeAlso">See Also</h1>
<ul>
<li>
<a href="Digitrax.shtml">JMRI's general Digitrax support page</a>
</li>
<li>The JMRI <a href="../../apps/DecoderPro/Roster.shtml">Rosters</a> page.
</li>
<li>The JMRI <a href="CommandStationConfig.shtml">Command Station Configuration</a> page
describes how to configure command station OpSw settings.
</li>
<li>For more information on the DCS52 itself, please consult the Digitrax website:
<ul>
<li>The Digitrax <a href=
"https://www.digitrax.com/products/command-stations-boosters/dcs52/">DCS52</a> product
page.
</li>
<li>The Digitrax <a href="https://www.digitrax.com/tsd/product/DCS52/">DCS52 Support</a>
page.
</li>
<li>Drivers for Windows-based machines may be found at the Digitrax <a href=
"https://www.digitrax.com/downloads/">Downloads</a> page. Note: Use the Digitrax PR3
drivers with the DCS52 USB interface.
</li>
</ul>
</li>
</ul>
<p>LocoNet&reg; is a registered trademark of <a href="https://www.digitrax.com">Digitrax,
Inc.</a></p>