StartCountSspClk() declared its tmr_input_config_type on the stack
without initialising it and never set input_filter_value.
tmr_input_channel_init() copies that field into TMR2 CM1.C2DF, so the
digital input filter on the ssp_clk pin took whatever low nibble was
left on the stack, and could change from call to call depending on
the caller's stack contents.
TMR2 is clocked by that filtered input (C2DF2, external clock mode A),
so the filter decides which ssp_clk edges get counted. With fDTS at
288 MHz, filter values around 13 need ~556 ns of stable input against
a ~590 ns ssp_clk half period (fc/16 in 14a reader modes). Edges are
then dropped some of the time, and 14-15 drop every edge. In sniffer
mode (fc/8) values from about 10 already break. Lost ticks delay
frame timing derived from GetCountSspClk() (ReaderTransmit timing,
sync_time loops) by a varying amount. This shows up as random nonce
distance jitter and slow distance calibration in hf mf nested/autopwn
on PM5.
Zero-initialise the struct so the filter is off (C2DF = 0), matching
StartLoEdgeCapture() in the same file.
Reported by @adrian-stepien in #3709.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Read SBS before TIME/DATE to latch a coherent snapshot in synchronous
ERTC mode. A rollover between the previous calendar and subsecond reads
could move the tick count backwards and cause false receive timeouts.
Preserve millisecond conversion and shared delta-helper semantics.
Add actual-source rollover, conversion and register-locking coverage.
Leave acquisition limits and RF timing unchanged.
Co-Authored-By: OpenAI coding assistant <noreply@openai.com>
Signed-off-by: nip <182409448+nip-was-here@users.noreply.github.com>
Simulation now completes the full exchange with a genuine Paxton reader in
password mode, and crypto mode read/write passes Proxmark-to-Proxmark.
Firmware:
- SOF was one bit period short. The lead-in that compensated for the lost
head half bit was removed and nothing replaced it, so readers rejected
every answer with a second START_AUTH. Default is now 6.
- The edge-detect threshold was latched before being measured, so the value
chosen depended on whether the Proxmark was in a field when sim started.
It is now measured on field entry and re-armed when the reader leaves.
- The percentile walk latched on run-scoped variables, so one attempt made
outside a field poisoned every later one.
- Field loss was detected from TIMESTAMP, which is free-running MCU time and
never stalls. Detect it from receive silence instead.
- Frames of a length the protocol does not have no longer reach the state
machine; our own modulation tail was resetting the session and breaking
every write.
- A dropped edge merges two or three reader bit periods into one gap. Those
bits were discarded; they are now recovered by decomposition, which is what
made crypto mode work (AUTH decode 15% -> 100%).
- Threshold selection is limited to 20 and 32 and settles in under 25 ms.
Client:
- lf hitag info printed a hardcoded 0x06 and reported 'Password mode' for
every tag. It now reads page 3, takes -k (4 bytes password, 6 bytes
crypto), and says so when the config cannot be read.
- lf hitag restore: writes a dump back in dependency order - user pages,
then key material, then config last - validates the config byte, and
prints the credential the tag will require afterwards.
- lf hitag crack2 now reports why it failed instead of a bare 'fail'.
- trace list: bit count moved to its own column, relative mode shows a
Frame Delay Time row rather than renaming Start/End, --frame and -r
rejected together.