[bot] [main] Automated version update
This commit is contained in:
@@ -16,7 +16,7 @@ spec:
|
||||
rules:
|
||||
- alert: NodeFilesystemSpaceFillingUp
|
||||
annotations:
|
||||
description: Filesystem on {{ $labels.device }} at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available space left and is filling up.
|
||||
description: Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available space left and is filling up.
|
||||
runbook_url: https://runbooks.prometheus-operator.dev/runbooks/node/nodefilesystemspacefillingup
|
||||
summary: Filesystem is predicted to run out of space within the next 24 hours.
|
||||
expr: |
|
||||
@@ -32,7 +32,7 @@ spec:
|
||||
severity: warning
|
||||
- alert: NodeFilesystemSpaceFillingUp
|
||||
annotations:
|
||||
description: Filesystem on {{ $labels.device }} at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available space left and is filling up fast.
|
||||
description: Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available space left and is filling up fast.
|
||||
runbook_url: https://runbooks.prometheus-operator.dev/runbooks/node/nodefilesystemspacefillingup
|
||||
summary: Filesystem is predicted to run out of space within the next 4 hours.
|
||||
expr: |
|
||||
@@ -48,7 +48,7 @@ spec:
|
||||
severity: critical
|
||||
- alert: NodeFilesystemAlmostOutOfSpace
|
||||
annotations:
|
||||
description: Filesystem on {{ $labels.device }} at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available space left.
|
||||
description: Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available space left.
|
||||
runbook_url: https://runbooks.prometheus-operator.dev/runbooks/node/nodefilesystemalmostoutofspace
|
||||
summary: Filesystem has less than 5% space left.
|
||||
expr: |
|
||||
@@ -62,7 +62,7 @@ spec:
|
||||
severity: warning
|
||||
- alert: NodeFilesystemAlmostOutOfSpace
|
||||
annotations:
|
||||
description: Filesystem on {{ $labels.device }} at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available space left.
|
||||
description: Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available space left.
|
||||
runbook_url: https://runbooks.prometheus-operator.dev/runbooks/node/nodefilesystemalmostoutofspace
|
||||
summary: Filesystem has less than 3% space left.
|
||||
expr: |
|
||||
@@ -76,7 +76,7 @@ spec:
|
||||
severity: critical
|
||||
- alert: NodeFilesystemFilesFillingUp
|
||||
annotations:
|
||||
description: Filesystem on {{ $labels.device }} at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available inodes left and is filling up.
|
||||
description: Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available inodes left and is filling up.
|
||||
runbook_url: https://runbooks.prometheus-operator.dev/runbooks/node/nodefilesystemfilesfillingup
|
||||
summary: Filesystem is predicted to run out of inodes within the next 24 hours.
|
||||
expr: |
|
||||
@@ -92,7 +92,7 @@ spec:
|
||||
severity: warning
|
||||
- alert: NodeFilesystemFilesFillingUp
|
||||
annotations:
|
||||
description: Filesystem on {{ $labels.device }} at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available inodes left and is filling up fast.
|
||||
description: Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available inodes left and is filling up fast.
|
||||
runbook_url: https://runbooks.prometheus-operator.dev/runbooks/node/nodefilesystemfilesfillingup
|
||||
summary: Filesystem is predicted to run out of inodes within the next 4 hours.
|
||||
expr: |
|
||||
@@ -108,7 +108,7 @@ spec:
|
||||
severity: critical
|
||||
- alert: NodeFilesystemAlmostOutOfFiles
|
||||
annotations:
|
||||
description: Filesystem on {{ $labels.device }} at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available inodes left.
|
||||
description: Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available inodes left.
|
||||
runbook_url: https://runbooks.prometheus-operator.dev/runbooks/node/nodefilesystemalmostoutoffiles
|
||||
summary: Filesystem has less than 5% inodes left.
|
||||
expr: |
|
||||
@@ -122,7 +122,7 @@ spec:
|
||||
severity: warning
|
||||
- alert: NodeFilesystemAlmostOutOfFiles
|
||||
annotations:
|
||||
description: Filesystem on {{ $labels.device }} at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available inodes left.
|
||||
description: Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available inodes left.
|
||||
runbook_url: https://runbooks.prometheus-operator.dev/runbooks/node/nodefilesystemalmostoutoffiles
|
||||
summary: Filesystem has less than 3% inodes left.
|
||||
expr: |
|
||||
@@ -140,7 +140,7 @@ spec:
|
||||
runbook_url: https://runbooks.prometheus-operator.dev/runbooks/node/nodenetworkreceiveerrs
|
||||
summary: Network interface is reporting many receive errors.
|
||||
expr: |
|
||||
rate(node_network_receive_errs_total[2m]) / rate(node_network_receive_packets_total[2m]) > 0.01
|
||||
rate(node_network_receive_errs_total{job="node-exporter"}[2m]) / rate(node_network_receive_packets_total{job="node-exporter"}[2m]) > 0.01
|
||||
for: 1h
|
||||
labels:
|
||||
severity: warning
|
||||
@@ -150,7 +150,7 @@ spec:
|
||||
runbook_url: https://runbooks.prometheus-operator.dev/runbooks/node/nodenetworktransmiterrs
|
||||
summary: Network interface is reporting many transmit errors.
|
||||
expr: |
|
||||
rate(node_network_transmit_errs_total[2m]) / rate(node_network_transmit_packets_total[2m]) > 0.01
|
||||
rate(node_network_transmit_errs_total{job="node-exporter"}[2m]) / rate(node_network_transmit_packets_total{job="node-exporter"}[2m]) > 0.01
|
||||
for: 1h
|
||||
labels:
|
||||
severity: warning
|
||||
@@ -160,12 +160,12 @@ spec:
|
||||
runbook_url: https://runbooks.prometheus-operator.dev/runbooks/node/nodehighnumberconntrackentriesused
|
||||
summary: Number of conntrack are getting close to the limit.
|
||||
expr: |
|
||||
(node_nf_conntrack_entries / node_nf_conntrack_entries_limit) > 0.75
|
||||
(node_nf_conntrack_entries{job="node-exporter"} / node_nf_conntrack_entries_limit) > 0.75
|
||||
labels:
|
||||
severity: warning
|
||||
- alert: NodeTextFileCollectorScrapeError
|
||||
annotations:
|
||||
description: Node Exporter text file collector failed to scrape.
|
||||
description: Node Exporter text file collector on {{ $labels.instance }} failed to scrape.
|
||||
runbook_url: https://runbooks.prometheus-operator.dev/runbooks/node/nodetextfilecollectorscrapeerror
|
||||
summary: Node Exporter text file collector failed to scrape.
|
||||
expr: |
|
||||
@@ -174,7 +174,7 @@ spec:
|
||||
severity: warning
|
||||
- alert: NodeClockSkewDetected
|
||||
annotations:
|
||||
description: Clock on {{ $labels.instance }} is out of sync by more than 0.05s. Ensure NTP is configured correctly on this host.
|
||||
description: Clock at {{ $labels.instance }} is out of sync by more than 0.05s. Ensure NTP is configured correctly on this host.
|
||||
runbook_url: https://runbooks.prometheus-operator.dev/runbooks/node/nodeclockskewdetected
|
||||
summary: Clock skew detected.
|
||||
expr: |
|
||||
@@ -194,7 +194,7 @@ spec:
|
||||
severity: warning
|
||||
- alert: NodeClockNotSynchronising
|
||||
annotations:
|
||||
description: Clock on {{ $labels.instance }} is not synchronising. Ensure NTP is configured on this host.
|
||||
description: Clock at {{ $labels.instance }} is not synchronising. Ensure NTP is configured on this host.
|
||||
runbook_url: https://runbooks.prometheus-operator.dev/runbooks/node/nodeclocknotsynchronising
|
||||
summary: Clock not synchronising.
|
||||
expr: |
|
||||
@@ -206,9 +206,9 @@ spec:
|
||||
severity: warning
|
||||
- alert: NodeRAIDDegraded
|
||||
annotations:
|
||||
description: RAID array '{{ $labels.device }}' on {{ $labels.instance }} is in degraded state due to one or more disks failures. Number of spare drives is insufficient to fix issue automatically.
|
||||
description: RAID array '{{ $labels.device }}' at {{ $labels.instance }} is in degraded state due to one or more disks failures. Number of spare drives is insufficient to fix issue automatically.
|
||||
runbook_url: https://runbooks.prometheus-operator.dev/runbooks/node/noderaiddegraded
|
||||
summary: RAID Array is degraded
|
||||
summary: RAID Array is degraded.
|
||||
expr: |
|
||||
node_md_disks_required{job="node-exporter",device=~"(/dev/)?(mmcblk.p.+|nvme.+|rbd.+|sd.+|vd.+|xvd.+|dm-.+|md.+|dasd.+)"} - ignoring (state) (node_md_disks{state="active",job="node-exporter",device=~"(/dev/)?(mmcblk.p.+|nvme.+|rbd.+|sd.+|vd.+|xvd.+|dm-.+|md.+|dasd.+)"}) > 0
|
||||
for: 15m
|
||||
@@ -216,9 +216,9 @@ spec:
|
||||
severity: critical
|
||||
- alert: NodeRAIDDiskFailure
|
||||
annotations:
|
||||
description: At least one device in RAID array on {{ $labels.instance }} failed. Array '{{ $labels.device }}' needs attention and possibly a disk swap.
|
||||
description: At least one device in RAID array at {{ $labels.instance }} failed. Array '{{ $labels.device }}' needs attention and possibly a disk swap.
|
||||
runbook_url: https://runbooks.prometheus-operator.dev/runbooks/node/noderaiddiskfailure
|
||||
summary: Failed device in RAID array
|
||||
summary: Failed device in RAID array.
|
||||
expr: |
|
||||
node_md_disks{state="failed",job="node-exporter",device=~"(/dev/)?(mmcblk.p.+|nvme.+|rbd.+|sd.+|vd.+|xvd.+|dm-.+|md.+|dasd.+)"} > 0
|
||||
labels:
|
||||
@@ -247,6 +247,75 @@ spec:
|
||||
for: 15m
|
||||
labels:
|
||||
severity: critical
|
||||
- alert: NodeCPUHighUsage
|
||||
annotations:
|
||||
description: |
|
||||
CPU usage at {{ $labels.instance }} has been above 90% for the last 15 minutes, is currently at {{ printf "%.2f" $value }}%.
|
||||
runbook_url: https://runbooks.prometheus-operator.dev/runbooks/node/nodecpuhighusage
|
||||
summary: High CPU usage.
|
||||
expr: |
|
||||
sum without(mode) (avg without (cpu) (rate(node_cpu_seconds_total{job="node-exporter", mode!="idle"}[2m]))) * 100 > 90
|
||||
for: 15m
|
||||
labels:
|
||||
severity: info
|
||||
- alert: NodeSystemSaturation
|
||||
annotations:
|
||||
description: |
|
||||
System load per core at {{ $labels.instance }} has been above 2 for the last 15 minutes, is currently at {{ printf "%.2f" $value }}.
|
||||
This might indicate this instance resources saturation and can cause it becoming unresponsive.
|
||||
runbook_url: https://runbooks.prometheus-operator.dev/runbooks/node/nodesystemsaturation
|
||||
summary: System saturated, load per core is very high.
|
||||
expr: |
|
||||
node_load1{job="node-exporter"}
|
||||
/ count without (cpu, mode) (node_cpu_seconds_total{job="node-exporter", mode="idle"}) > 2
|
||||
for: 15m
|
||||
labels:
|
||||
severity: warning
|
||||
- alert: NodeMemoryMajorPagesFaults
|
||||
annotations:
|
||||
description: |
|
||||
Memory major pages are occurring at very high rate at {{ $labels.instance }}, 500 major page faults per second for the last 15 minutes, is currently at {{ printf "%.2f" $value }}.
|
||||
Please check that there is enough memory available at this instance.
|
||||
runbook_url: https://runbooks.prometheus-operator.dev/runbooks/node/nodememorymajorpagesfaults
|
||||
summary: Memory major page faults are occurring at very high rate.
|
||||
expr: |
|
||||
rate(node_vmstat_pgmajfault{job="node-exporter"}[5m]) > 500
|
||||
for: 15m
|
||||
labels:
|
||||
severity: warning
|
||||
- alert: NodeMemoryHighUtilization
|
||||
annotations:
|
||||
description: |
|
||||
Memory is filling up at {{ $labels.instance }}, has been above 90% for the last 15 minutes, is currently at {{ printf "%.2f" $value }}%.
|
||||
runbook_url: https://runbooks.prometheus-operator.dev/runbooks/node/nodememoryhighutilization
|
||||
summary: Host is running out of memory.
|
||||
expr: |
|
||||
100 - (node_memory_MemAvailable_bytes{job="node-exporter"} / node_memory_MemTotal_bytes{job="node-exporter"} * 100) > 90
|
||||
for: 15m
|
||||
labels:
|
||||
severity: warning
|
||||
- alert: NodeDiskIOSaturation
|
||||
annotations:
|
||||
description: |
|
||||
Disk IO queue (aqu-sq) is high on {{ $labels.device }} at {{ $labels.instance }}, has been above 10 for the last 15 minutes, is currently at {{ printf "%.2f" $value }}.
|
||||
This symptom might indicate disk saturation.
|
||||
runbook_url: https://runbooks.prometheus-operator.dev/runbooks/node/nodediskiosaturation
|
||||
summary: Disk IO queue is high.
|
||||
expr: |
|
||||
rate(node_disk_io_time_weighted_seconds_total{job="node-exporter", device=~"(/dev/)?(mmcblk.p.+|nvme.+|rbd.+|sd.+|vd.+|xvd.+|dm-.+|md.+|dasd.+)"}[5m]) > 10
|
||||
for: 30m
|
||||
labels:
|
||||
severity: warning
|
||||
- alert: NodeSystemdServiceFailed
|
||||
annotations:
|
||||
description: Systemd service {{ $labels.name }} has entered failed state at {{ $labels.instance }}
|
||||
runbook_url: https://runbooks.prometheus-operator.dev/runbooks/node/nodesystemdservicefailed
|
||||
summary: Systemd service has entered failed state.
|
||||
expr: |
|
||||
node_systemd_unit_state{job="node-exporter", state="failed"} == 1
|
||||
for: 5m
|
||||
labels:
|
||||
severity: warning
|
||||
- name: node-exporter.rules
|
||||
rules:
|
||||
- expr: |
|
||||
|
||||
Reference in New Issue