- Corrected Back-EMF measurement CV from CV63 to CV61.
- Rewrote 'Startup Controller' section for clarity and accuracy.
- Added Sphinx C cross-references for get_kp(), init_controller(), and speed_helper() functions.
Adds in-detail descriptions of the features used in the motor control to the documentation.
This includes:
- Speed Table Initialization
- Startup Controller logic
- Gain Scheduling (`get_kp` function)
- Speed Helper (acceleration/deceleration)
- Back-EMF voltage measurement details