176 lines
7.0 KiB
Plaintext
176 lines
7.0 KiB
Plaintext
<!DOCTYPE html>
|
|
<html lang="en">
|
|
<head>
|
|
<meta name="generator" content="HTML Tidy for HTML5 for Apple macOS version 5.8.0">
|
|
<title>JMRI: Monitor LocoNet Traffic</title>
|
|
<meta name="author" content="Bob Jacobsen">
|
|
<meta name="author" content="B.Milhaupt">
|
|
<meta name="keywords" content="JMRI help monitor loconet traffic message packet">
|
|
<!--#include virtual="/help/en/parts/Style.shtml" -->
|
|
<!-- center class -->
|
|
|
|
<style>
|
|
.ctr {text-align: center;}
|
|
</style>
|
|
</head>
|
|
<body>
|
|
<!--#include virtual="/help/en/parts/Header.shtml" -->
|
|
|
|
<div id="mBody">
|
|
<div id="mainContent" class="no-sidebar">
|
|
<h1>Monitor LocoNet Traffic</h1>
|
|
<a href="../../../../../html/hardware/loconet/images/LocoMonFrame.png"><img src=
|
|
"../../../../../html/hardware/loconet/images/LocoMonFrame.png" width="300" height="150" alt=
|
|
"Command Station Slot Monitor" class="floatRight"></a><br>
|
|
The LocoNet Monitor tool displays LocoNet traffic in a human-readable form. The most recent
|
|
messages are available in a scrolling window. Optionally, you can include the time the
|
|
message was received, and/or the raw packet bytes. The log information can also be stored in
|
|
a text file.
|
|
|
|
<h2>LocoNet Monitor "Controls"</h2>
|
|
For more information on the various controls and options, please see the <a href=
|
|
"../../AbstractMonFrame.shtml">Communications Monitor Window page</a>.
|
|
|
|
<h2>LocoNet Monitor "Raw Data"</h2>
|
|
|
|
<p>When the LocoNet Monitor is configured to include "raw data" in its output, it
|
|
differentiates between messages sent by JMRI to the interface hardware and those messages
|
|
coming back from the LocoNet interface hardware. The "Raw data" for those messages which JMRI
|
|
sends to the LocoNet interface hardware are prefixed with "Tx - ". The "Raw data" for those
|
|
messages which the LocoNet interface hardware provides to JMRI are prefixed with "Rx - ".</p>
|
|
|
|
<h2>LocoNet Monitor Timestamps</h2>
|
|
|
|
<p>When Timestamps are enabled, each message is preceeded by the computer time when JMRI sees
|
|
the message. For a variety of technical reasons, these timestamps cannot reflect the actual
|
|
time when the message is on the LocoNet data wires.</p>
|
|
|
|
<p>Because of this, a wide range of odd effects can be seen. Two different messages can be
|
|
shown with the same timestamp. A transmit message and a receive message can have the same
|
|
timestamp. And a "Rx" message show up in the display before the "Tx" message is shown.</p>
|
|
|
|
<p>These behaviors are normal and expected, even though they can be annoying. These behaviors
|
|
result from a combination of the implementations of JMRI, Java, the computer operating
|
|
system, the computer hardware and the LocoNet interface hardware. As such, the JMRI
|
|
implementation has very little control over these odd behaviors, although the JMRI developers
|
|
have attempted to minimize the influence of these odd behaviors upon JMRI.</p>
|
|
|
|
<h2>Filtering LocoNet Messages</h2>
|
|
|
|
<p>Users may specify LocoNet "OpCode" values which should be filtered (ignored) by LocoNet
|
|
Monitor. Filtering messages in LocoNet monitor does <strong>not</strong> prevent messages
|
|
from getting to other JMRI components, and does <strong>not</strong> prevent messages from
|
|
being sent to the LocoNet interface hardware; filtering only affects the display of LocoNet
|
|
messages.</p>
|
|
|
|
<p>The "Filter Bytes:" text entry area on the LocoNet monitor window may be used to specify
|
|
one or more LocoNet message "OpCode(s)". When the LocoNet monitor is notified of a LocoNet
|
|
message, the message's OpCode value is compared to the hexadecimal value(s) in the "Filter
|
|
Bytes:" text entry area. If the message's OpCode value is specified in the text entry area,
|
|
then the LocoNet monitor will ignore the message.</p>
|
|
|
|
<p>A LocoNet OpCode value is entered as a two character hexadecimal value, such as "81", "A0"
|
|
and "E5", without quotes. When multiple OpCode values are to be filtered, provide a space
|
|
between each value, such as "81 E5 A0" (without quotes).</p>
|
|
|
|
<p>The filtering mechanism checks only the first byte of the LocoNet message. This means that
|
|
the filtering mechanism cannot specifically ignore those LocoNet messages which rely on more
|
|
than the OpCode value to define the specific LocoNet message. This is a known limitation of
|
|
the message filtering mechanism.</p>
|
|
|
|
<p>Specific information on many LocoNet OpCode values can be found in documentation provided
|
|
by Digitrax, while others are not publicly documented. Below is a short list of some OpCode
|
|
values and the associated LocoNet functionality.</p>
|
|
|
|
<table border='2'>
|
|
<tr>
|
|
<td class="ctr" colspan="2"><strong>Some LocoNet OpCode values and their
|
|
functionality</strong>
|
|
</td>
|
|
</tr>
|
|
|
|
<tr>
|
|
<td class="ctr"><strong>OpCode Value (Hexadecimal)</strong>
|
|
</td>
|
|
<td class="ctr"><strong>Functionality</strong>
|
|
</td>
|
|
</tr>
|
|
|
|
<tr>
|
|
<td class="ctr">81</td>
|
|
<td>Master (command station) is busy</td>
|
|
</tr>
|
|
|
|
<tr>
|
|
<td class="ctr">B0</td>
|
|
<td>Control switch position (without acknowledgment)</td>
|
|
</tr>
|
|
|
|
<tr>
|
|
<td class="ctr">B1</td>
|
|
<td>Switch position report</td>
|
|
</tr>
|
|
|
|
<tr>
|
|
<td class="ctr">B2</td>
|
|
<td>General sensor state report</td>
|
|
</tr>
|
|
|
|
<tr>
|
|
<td class="ctr">B4</td>
|
|
<td>Long acknowledge - sent by command station in response to a large variety of LocoNet
|
|
messages</td>
|
|
</tr>
|
|
|
|
<tr>
|
|
<td class="ctr">B8</td>
|
|
<td>Unlink (de-consist) two slots</td>
|
|
</tr>
|
|
|
|
<tr>
|
|
<td class="ctr">B9</td>
|
|
<td>Link (consist) two slots</td>
|
|
</tr>
|
|
|
|
<tr>
|
|
<td class="ctr">BC</td>
|
|
<td>Request current position of Switch</td>
|
|
</tr>
|
|
|
|
<tr>
|
|
<td class="ctr">BD</td>
|
|
<td>Control switch position</td>
|
|
</tr>
|
|
|
|
<tr>
|
|
<td class="ctr">E4</td>
|
|
<td>Uhlenbrock LISSY automatic train detection and RFID tag readers</td>
|
|
</tr>
|
|
|
|
<tr>
|
|
<td class="ctr">E7</td>
|
|
<td>Slot data report - locomotive control, programming track, fast clock, etc.</td>
|
|
</tr>
|
|
|
|
<tr>
|
|
<td class="ctr">ED</td>
|
|
<td>Mobile decoder function control (F9-F28), control of some stationary decoders,
|
|
etc.</td>
|
|
</tr>
|
|
|
|
<tr>
|
|
<td class="ctr">EF</td>
|
|
<td>Write slot - locomotive control, programming track, fast clock, etc.</td>
|
|
</tr>
|
|
</table>
|
|
|
|