<h1>Configure Digitrax BDL16x</h1>
|
|
|
|
<p>The JMRI BDL16x programming tool lets you configure the internal options of a BDL16,
|
|
BDL162, or BDL168 directly from your computer, when the board is connected to a JMRI LocoNet
|
|
connection.</p>
|
|
|
|
<p>To open this tool select "Configure BDL16/BDL162/BDL168" from the LocoNet menu.</p>
|
|
|
|
<h2>Selecting the BDL16x board</h2>
|
|
|
|
<p>Each BDL16x device present on the LocoNet connection is identified by its "Board ID". This
|
|
tool may access a particular BDL16x device by entering the "Board ID" number in the selection
|
|
box at the upper left of the tool window.</p>
|
|
|
|
<p>Upon start-up, this tool queries the LocoNet connection to create a list of BDL16x
|
|
devices. Each BDL16x Board ID is added to the list in the pull-down selector, accessed by
|
|
selecting the downward-pointing triangle which is just to the right of the Board ID text
|
|
entry space.</p>
|
|
|
|
<p>Any time that a Board ID number is typed into the Board ID text entry space, the number
|
|
will be added to the list if it is not already present in the list.</p>
|
|
|
|
<p>While it is possible to change the Board ID number using JMRI, it cannot be done using
|
|
this tool due to limitations of the BDL16x design. Instead, follow the instructions found
|
|
<a href="../../../../../html/hardware/loconet/Digitrax.shtml#deviceBoardId">here</a>. Those
|
|
instructions are for programming a BDL168 board, but they are believed to apply also to BDL16
|
|
and BDL162 boards.</p>
|
|
|
|
<h2>Reading and writing the OpSw settings</h2>
|
|
|
|
<p>This tool only accesses the board's OpSw values when the "Read Full Sheet" or "Write Full
|
|
Sheet" button is pressed.</p>
|
|
|
|
<p>The "Read Full Sheet" button may be used to read the OpSw settings from the BDL16x.
|
|
Performing the "Read Full Sheet" operation reads all OpSw values from the board selected by
|
|
the "Board ID" field and updates each of the tool's selections.</p>
|
|
|
|
<p>The "Write Full Sheet" button may be used to write the OpSw settings currently shown in
|
|
the tool to the BDL16x device specified by the "Board ID" number shown at the top of the
|
|
window. Performing the "Write Full Sheet" operation writes all OpSw values to the board.</p>
|
|
|
|
<h2>The configurable options</h2>
|
|
|
|
<p>The basic operating settings are shown grouped into three sections:</p>
|
|
|
|
<ul>
|
|
<li>The top-most section shows the options which apply to all BDL16x types.</li>
|
|
|
|
<li>Immediately below are the basic operating settings which apply only to the BDL162 and
|
|
BDL168.</li>
|
|
|
|
<li>Below this are the basic operating settings which apply only to the BDL168.</li>
|
|
</ul>
|
|
|
|
<p>Each setting may be changed by selecting one of the options from the pull-down list of
|
|
values.</p>
|
|
|
|
<p>When performing a "Write Full Sheet" operation to a BDL16 or BDL162 device, this tool will
|
|
write all of the OpSw values, not just the OpSw values which are defined for the BDL16 or
|
|
BDL162 device. This is thought to be safe, as it is thought that these OpSw values will be
|
|
ignored by the hardware. If you are concerned that this may not be acceptable, then select
|
|
the "default" value for the OpSw values which do not apply to the board type which you are
|
|
configuring.</p>
|
|
|
|
<h2>Limitations</h2>
|
|
|
|
<ul>
|
|
<li>This tool is not able to detect the difference between a BDL16, a BDL162, and a BDL168.
|
|
As such, it always shows all OpSw values and descriptions for the BDL168, and the "Write
|
|
Full Sheet" operation will write all OpSw values.</li>
|
|
|
|
<li>This tool is able to access BDL16x boards with addresses between 1 and 128. Users are
|
|
advised to avoid using the factory default board address (board address 1) as it will be
|
|
difficult to program new boards with unique data if any in-service board is using the
|
|
factory default board address.</li>
|
|
|
|
<li>Because of the way the BDL16x board works, this tool can't change the basic address of
|
|
the unit. The BDL16x documentation describes how to change the board address. It is
|
|
possible to change the Board ID number using JMRI by following the instructions found
|
|
<a href="../../../../../html/hardware/loconet/Digitrax.shtml#deviceBoardId">here</a>. Those
|
|
instructions are for programming a BDL168 board, but they are believed to apply also to
|
|
BDL16 and BDL162 boards.
|
|
</li>
|
|
</ul>
|
|
|
|
<h2>See Also</h2>
|
|
|
|
<p>Documentation for the BDL16, BDL162, and BDL168 can be found at the <a href=
|
|
"http://www.digitrax.com">Digitrax Web Site.</a></p>
|
|
<!--#include virtual="/help/en/parts/Footer.shtml" -->
|
|
</div>
|
|
<!-- closes #mainContent-->
|
|
</div>
|
|
<!-- closes #mBody-->
|
|
<script src="/js/help.js"></script>
|
|
</body>
|
|
</html>
|