<?xml version="1.0" encoding="utf-8"?>
<?xml-stylesheet type="text/xsl" href="../XSLT/decoder.xsl"?>
<decoder-config xmlns:xi="http://www.w3.org/2001/XInclude"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xsi:noNamespaceSchemaLocation="http://jmri.org/xml/schema/decoder-4-15-2.xsd"
showEmptyPanes="no"
suppressFunctionLabels="yes"
suppressRosterMedia="yes"
>
<version author="Bob Jacobsen" version="1" lastUpdated="20230205" />
<version author="Bob Milhaupt" version="2" lastUpdated="20240708" />
<decoder>
<family name="Series 7 Boards" mfg="Digitrax">
<model model="DS74"/>
</family>
<programming direct="no" paged="yes" register="no" ops="no">
<!-- paged yes allows initial setup and change of address -->
<mode>LOCONETBD7OPSWMODE</mode>
</programming>
<variables>
<variable CV="1" comment="Base Address" item="Long Address" default="1" infoOnly="yes" >
<!-- This is needed to set the Base Address value.
2037 is a practical maximum.
Note that the DS74 will allow higher numbers
to be set, but they will conflict with the
"interrogate" switches. -->
<splitVal highCV="2" upperMask="XXXXXVVV" default="0" min="1" max="2037"/>
<label>Base Address</label>
</variable>
<!-- CV7 is the product ID. Should be 0x74 (116 decimal) -->
<variable CV="7" item="Device Type" readOnly="yes">
<decVal min="0" max="255" />
<label>Device Type</label>
</variable>
<variable CV="8" item="Device Mfgr" readOnly="yes">
<decVal min="0" max="255"/>
<label>Device Manufacturer (NMRA number) </label>
</variable>
<variable CV="9" item="Serial Number" default="0" mask="VVVVVVVV" readOnly="yes">
<splitVal highCV="10" upperMask="VVVVVVVV"/>
<label>Serial Number</label>
</variable>
<variable CV="11" item="Output Type" default="0" tooltip="OpSw1-4" mask="XXXXVVVV">
<enumVal>
<enumChoice value="0">
<choice>pulse solenoid (4 outputs)</choice>
</enumChoice>
<enumChoice value="1">
<choice>slow motion (4 outputs)</choice>
</enumChoice>
<enumChoice value="5">
<choice>Light mode (8 outputs)</choice>
</enumChoice>
</enumVal>
<label>Output type: </label>
</variable>
<variable CV="11" item="Internal Routes" default="0" tooltip="OpSw06" mask="XXVXXXXX">
<enumVal>
<enumChoice>
<choice>enabled</choice>
</enumChoice>
<enumChoice>
<choice>disabled</choice>
</enumChoice>
</enumVal>
<label>Internal Routes are</label>
</variable>
<variable CV="12" item="Bushby" default="0" tooltip="OpSw10" mask="XXXXXXVX">
<enumVal>
<enumChoice>
<choice>disabled</choice>
</enumChoice>
<enumChoice>
<choice>enabled</choice>
</enumChoice>
</enumVal>
<label>Bushby Bit is</label>
</variable>
<variable CV="12" item="Input Lines" default="0" tooltip="OpSw11" mask="XXXXXVXX">
<enumVal>
<enumChoice>
<choice>do turnout, sensor commands</choice>
</enumChoice>
<enumChoice>
<choice>trigger routes</choice>
</enumChoice>
</enumVal>
<label>Input Lines</label>
</variable>
<variable CV="12" item="Command Source" default="0" tooltip="OpSw14" mask="XXVXXXXX">
<enumVal>
<enumChoice>
<choice>Loconet switch commands</choice>
</enumChoice>
<enumChoice>
<choice>DCC switch commands only</choice>
</enumChoice>
</enumVal>
<label>Command source is</label>
</variable>
<variable CV="12" item="Route Echo" default="0" tooltip="OpSw15" mask="XVXXXXXX">
<enumVal>
<enumChoice>
<choice>echo to Loconet</choice>
</enumChoice>
<enumChoice>
<choice>do not echo to Loconet</choice>
</enumChoice>
</enumVal>
<label>Route Switch Commands</label>
</variable>
<variable CV="12" item="Solenoid Pulse" default="0" tooltip="OpSw16" mask="VXXXXXXX">
<enumVal>
<enumChoice>
<choice>normal</choice>
</enumChoice>
<enumChoice>
<choice>high CD voltage</choice>
</enumChoice>
</enumVal>
<label>Solenoid Pulse</label>
</variable>
<variable CV="14" item="InterrogateSwitches" default="0" tooltip="OpSw30" mask="XXVXXXXX">
<enumVal>
<enumChoice>
<choice>Disabled</choice>
</enumChoice>
<enumChoice>
<choice>Enabled</choice>
</enumChoice>
</enumVal>
<label>'Interrogate' causes reporting of switch positions: </label>
</variable>
<variable CV="16" item="CP1Led" default="0" tooltip="OpSw44 (13Dec2022 firmware and later)" mask="XXXXVXXX">
<enumVal>
<enumChoice>
<choice>Enabled</choice>
</enumChoice>
<enumChoice>
<choice>Disabled</choice>
</enumChoice>
</enumVal>
<label>CP1 LED is </label>
</variable>
</variables>
</decoder>
<pane xmlns:xi="http://www.w3.org/2001/XInclude" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="http://jmri.org/xml/schema/programmer.xsd">
<name>CVs</name>
<column>
<row>
<cvtable/>
</row>
<row>
<column>
<label>
<text>&lt;html&gt;The "CV" column in the table above shows CV
numbers, not the Op Switch number.&lt;p&gt;To see those, hover
your mouse over a variable on the OpSw Settings pane.
&lt;p&gt;CVs 1 and 2 are the low and high (respectively) 8-bit
"Base Address" values.&lt;p&gt;The "Base Address" is practically
limited to 2033, max.&lt;p&gt;The "Roster" tool and its
Roster entries &lt;em&gt; cannot&lt;/em&gt; change the
"Base Address".
</text>
</label>
</column>
</row>
</column>
</pane>
<pane>
<name>Basic</name>
<column>
<display item="Long Address"/>
<label>
<text>&lt;html&gt;
&lt;p&gt;This roster entry will only access the specified
board if the Base Address specified above &lt;br&gt;was
correctly entered when the roster entry was first created.
You &lt;em&gt;cannot&lt;/em&gt; change it in the Roster Entry.
&lt;/html&gt;</text>
</label>
<label>
<text> </text>
</label>
<display item="Device Type"/>
<display item="Device Mfgr"/>
<display item="Serial Number"/>
</column>
</pane>
<pane>
<name>OpSw Settings</name>
<column>
<label><text>&lt;html&gt;&lt;span style=&quot;color: black;&quot;&gt;&lt;h2&gt;&lt;strong&gt;Output Controls Characteristics&lt;/strong&gt;&lt;/h2&gt;&lt;/html&gt;</text></label>
<display item="Output Type"/>
<display item="Solenoid Pulse"/>
<label><text> </text></label>
<separator/>
<label><text>&lt;html&gt;&lt;span style=&quot;color: black;&quot;&gt;&lt;h2&gt;&lt;strong&gt;Control Source Characteristics&lt;/strong&gt;&lt;/h2&gt;&lt;/html&gt;</text></label>
<display item="Command Source"/>
<display item="Bushby"/>
<label><text> </text></label>
<separator/>
<label><text>&lt;html&gt;&lt;span style=&quot;color: black;&quot;&gt;&lt;h2&gt;&lt;strong&gt;Local Inputs Characteristics&lt;/strong&gt;&lt;/h2&gt;&lt;/html&gt;</text></label>
<display item="Input Lines"/>
<label><text> </text></label>
<label>
<text>&lt;html&gt;&lt;span style=&quot;color: green;&quot;&gt;&lt;em&gt;
The "Interrogate Switches" settings, below, apply to
DS74 "April 7, 2022, &lt;p&gt; (version 0.4)" and later firmware. Previous firmware versions
do &lt;p&gt;not implement these OpSws.</text> </label>
<display item="InterrogateSwitches"/>
<label><text> </text></label>
<label>
<text>&lt;html&gt;&lt;span style=&quot;color: green;&quot;&gt;&lt;em&gt;
The "Interrogate Switches" settings, below, apply to
DS74 "December 13, 2022, &lt;p&gt; (version 0.6)" and later firmware. Previous firmware versions
do &lt;p&gt;not implement these OpSws.</text> </label>
<display item="CP1Led"/>
<label><text> </text></label>
<separator/>
<label><text>&lt;html&gt;&lt;span style=&quot;color: black;&quot;&gt;&lt;h2&gt;&lt;strong&gt;Local Routes Characteristics&lt;/strong&gt;&lt;/h2&gt;&lt;/html&gt;</text></label>
<display item="Internal Routes"/>
<display item="Route Echo"/>
</column>