<p><span class="since">since 5.12.3</span>The "Configure LocoIO (LNSV1) Modules" tool lets you access
|
|
and program connected LocoNet devices that respond to the LNSV version 1 LocoNet
|
|
programming protocol.<br>
|
|
Examples are the classic Jabour, HDL and GCA LocoIO boards. You find the
|
|
tool in the LocoNet menu as long as a LocoNet connection is available.</p>
|
|
|
|
<img src="images/LNSV1Tool1.png" alt="Initial view of LNSV1 Programming Tool pane">
|
|
|
|
<p>As this tool is new, you might use it in combination with the "Show Raw Data" option in the
|
|
<a href="../../locomon/LocoMonFrame.shtml">LocoNet Monitor</a> to check for any additional
|
|
responses rejected by the LNSV1 filters.</p>
|
|
|
|
<p>LNSV1 modules will respond to any Read and Write commands addressed to them
|
|
(only the Read button in the tool is enabled).</p>
|
|
|
|
<p>LNSV1 Responses coming back from the layout will be listed in the LNSV1 Monitor, and if not already in the
|
|
list, devices sending a read reply will be added to the Devices table.</p>
|
|
|
|
<h2>Module LNSV1 Programming</h2>
|
|
|
|
<p>LNSV1 Programming requires 3 elements to address an SV in an LNSV1 module on LocoNet:</p>
|
|
|
|
<ol>
|
|
<li>Low module address</li>
|
|
|
|
<li>High or module subaddress</li>
|
|
|
|
<li>SV number</li>
|
|
</ol>
|
|
|
|
<p>Enter the low address e.g. 81 in the field to the left of the slash, and enter the subaddress in the field
|
|
on the right.</p>
|
|
|
|
<p>After first starting the tool, existing LocoIO modules are detected on LocoNet. After a couple of seconds
|
|
they will appear in the table. Note the Version column and other properties.<br>
|
|
To repeat the probing, for example after you powered up a LocoIO, press the [Probe All] button at top left.</p>
|
|
|
|
<p>When your Roster contains (exactly) one entry for a decoder of the same DCC address (the value in the second
|
|
column), its name will be listed in the table as the Roster Entry ID, as shown below.<br>
|
|
When you have a matching Roster Entry, the button in the Program column will read
|
|
[Program] and will directly open the Roster Entry tabs.</p>
|
|
|
|
<img src="images/LNSV1Tool2.png"
|
|
alt="LNSV1 Programming Tool pane with one LNSV1 device selected and a No Match">
|
|
|
|
<p>When no match was found in your Roster, the button will read [No Match in Roster]. You may click on the
|
|
button to receive a short hint. That will tell you to open your Roster and
|
|
create a new Entry with the DCC address mentioned in the dialog.<br>
|
|
Be sure to complete the Entry creation process by clicking [Save to Roster] on the
|
|
DecoderPro Roster Entry tab.</p>
|
|
|
|
<p>When a matching DCC address was found in the Roster but that decoder doesn't support LNSV1
|
|
programming, we must assume it is a mismatch. Perhaps a decoder in one of the locos has the same address as one
|
|
of the LocoIO composite addresses.<br>
|
|
The button will read [Not for LNSV1] and you advised to change the LocoIO address.</p>
|
|
|
|
<h2>LNSV1 Read</h2>
|
|
<p>For incidental checking, the tool allows reading of individual SV values.<br>
|
|
<p>Click on one of the rows to copy a modules' address and SV last read to the top part of the pane.<br>
|
|
Enter an SV number in the SV: field on the right of the tool pane and click [Read] to
|
|
find the value returned in the Value: field.<br>
|
|
The [Write] button is disabled to prevent messing up the complicated LocoIO configuration variables (in contrast
|
|
to the <a href="../lncvprog/LncvProgPane.shtml">Configure LNCV</a> tool). DecoderPro <a
|
|
href="../../../../../../html/hardware/loconet/LocoIODefinition.shtml">Programming on Main</a> gives you
|
|
access to the full suite in a consistent and accessible way.</p>
|
|
|
|
<img src="images/LNSV1Tool3.png"
|
|
alt="LNSV1 Programming Tool pane with a selected device and address filled in">
|
|
|
|
<h2>Broadcast LNSV1 Programming</h2>
|
|
|
|
<p class="important">Click "Probe All" to start a session.</p>
|
|
|
|
<p>Module addresses can be changed from this tool using Broadcast mode [Set All Addresses] button, but you have
|
|
to make sure only one such device is powered, as they will all respond to broadcast programming commands.</p>
|
|
|
|
<p>WARNING: this will change the SV1 and SV2 address values in ALL connected LocoIO family boards</p>
|
|
|
|
<img src="images/LNSV1BroadcastWarning.png" alt="LocoIO (LNSV1) Tool warning for Broadcast">
|
|
|
|
<h2>LNSV1 Decoder definitions</h2>
|
|
|
|
<p>You use the
|
|
Roster entry programming panes for advanced (and accessible) configuration changes. Easily
|
|
switch to DecoderPro Roster either by clicking the [Program] button in the LNSV1 table or manually
|
|
open the entry for the module in your Roster entries list.<br>
|
|
Go to the "LocoIO" or "Ports" tabs to read and write options supported by the device.</p>
|
|
|
|
<p>Anyone interested in writing their own LNSV1 decoder definitions in JMRI, please note that
|
|
in the definition the programming mode should be defined as
|
|
<code><mode>LOCONETLNSV1MODE</mode></code>.</p>
|
|
|
|