<h1>LocoNet Util LNCV</h1>
|
|
|
|
<p><span class="since">since 4.21.4</span>The "Configure LNCV Modules" tool lets you access
|
|
and program connected LocoNet devices that respond to the (Uhlenbrock) LNCV LocoNet
|
|
programming protocol.<br>
|
|
Examples are the Uhlenbrock Switch Module 63410 and Digikeijs DR5033 booster. You find the
|
|
tool in the LocoNet menu as long as a LocoNet connection is available.</p>
|
|
<img src="images/LNCVTool1.png" alt="Initial view of LNCV Programming Tool pane"> <img src=
|
|
"images/LNCVTool2.png" alt="LNCV Programming Tool pane with Article and Address filled in">
|
|
<p>You might use this tool in combination with the "Show Raw Data" option in the
|
|
<a href="../../locomon/LocoMonFrame.shtml">LocoNet Monitor</a> to check for any additional
|
|
responses rejected by the LNCV filters.</p>
|
|
|
|
<p>Unless a programming session is running, LNCV modules will not respond to Write commands
|
|
(the Read and Write buttons in the tool are only enabled during a session).</p>
|
|
|
|
<h2>Module LNCV Programming</h2>
|
|
|
|
<p>LNCV Programming requires 3 elements to address CVs in an LNCV module on LocoNet:</p>
|
|
|
|
<ol>
|
|
<li>Article Number (aka type/class/productID)</li>
|
|
|
|
<li>Module Address (optional, see below)</li>
|
|
|
|
<li>CV number</li>
|
|
</ol>
|
|
|
|
<p>Uhlenbrock and Digikeijs/Digirails publish the Article number for each (new) device. For
|
|
example, the Digikeijs DigiBoost DR5033 has Article number 5033, which was registered with
|
|
Uhlenbrock. The Uhlenbrock 63330 has Article number 6333, the Uhlenbrock 63410 has 6341
|
|
(skip last zero).<br>
|
|
Enter the Article number e.g. 5033 in the "Article" field before proceeding.<br>
|
|
Next, enter the Module Address in the corresponding field.</p>
|
|
|
|
<p>After opening a programming session, the "Open Module Programming" stays highlighted and
|
|
the Read and Write buttons are enabled.<br>
|
|
To close the programming of a module, click the same button, that now reads "Stop Module
|
|
Programming".<br>
|
|
While a programming session is running this button is highlighted and the Address field is
|
|
not editable, to prevent switching module address without first closing the session running.
|
|
Note that changing the module address stored in CV0 won't immediately halt the session, so
|
|
take care and close the current session before opening a new session on the new module
|
|
address.</p>
|
|
|
|
<p>For incidental programming, the tool allows reading and writing of individual CV
|
|
values.<br>
|
|
To read, enter a CV number in the fields on the right of the tool pane and click [Read] to
|
|
see the value in the Value field.<br>
|
|
To write, enter a CV number plus the new value to set in the CV, and click [Write].</p>
|
|
|
|
<p>LNCV Responses coming back from the layout will be listed in the LNCV Monitor, and the
|
|
devices sending a reply show up in the Devices table.</p>
|
|
|
|
<p>When your Roster contains (exactly) one entry for a decoder of this article number and
|
|
address, it will be listed in the table as the Roster Entry ID, as shown below.<br>
|
|
When you have a matching Roster Entry, the button in the Program column will read
|
|
[Program] and will directly open the Roster Entry tabs.</p>
|
|
<img src=
|
|
"../../../../../../html/hardware/loconet/images/LncvProgrammer/LncvProgrammerPane.png" alt=
|
|
"LNCV Programming Tool can't find a matching definition">
|
|
|
|
<p>When no match was found in your Roster but a matching definition was found in the JMRI
|
|
Decoder Index, the button will read [Create Entry]. Click on it and enter an ID (name) for your new roster
|
|
entry.</p>
|
|
<img src="images/LNCVToolEntry.png" alt=
|
|
"LNCV Programming Tool ask for a name for the new Entry when you click Add Entry">
|
|
<p>After clicking [OK] the button is updated to [Program].</p>
|
|
<img src="images/LNCVTool3.png" alt="LNCV Programming Tool found a Decoder Entry and
|
|
shows Program button">
|
|
<p>Be sure to complete the Entry creation process by clicking [Save to Roster] on the
|
|
DecoderPro Roster Entry tab.</p>
|
|
|
|
<p>If your device responded to a general call but is not yet found in the Decoder Index,
|
|
the button will read [No Match in Roster].<br>
|
|
<span class="since">since 5.1.3</span>Click the button to get a dialog to recreate the
|
|
Decoder Index, as a new decoder file that was copied to the user files /decoder folder
|
|
might not yet be part of the Index.<br>
|
|
If that doesn't fix it, report your device on the jmri_users group or create an Issue in
|
|
GitHub.</p>
|
|
|
|
<h2>Broadcast LNCV Programming</h2>
|
|
|
|
<p>Older LNCV devices may not have their own address, or even no article ID. They can be
|
|
programmed using Broadcast mode, but you have to be sure only one such device is powered, as
|
|
they all would respond to programming commands.</p>
|
|
|
|
<p>Click "Start Broadcast Programming" to start a session.</p>
|
|
|
|
<p>To close a Broadcast session, click "Stop Broadcast Programming".</p>
|
|
|
|
<p>Using the universal address 65535 (or simply leaving the Article field empty) you can, as
|
|
the name suggests, call up all LNCV Adapters that want to respond (not all do).<br>
|
|
As the universal address is not valid for addressing specific modules, it can only be used to
|
|
call up an individual adapter for which the address is unknown. For this you connect ONLY the said
|
|
adapter to the LocoNet. The adapter can then be called up and its address read from LNCV
|
|
0.<br>
|
|
By only filling in an Article number (and leaving the address field empty) you can send a
|
|
Broadcast call to all devices of that specific type, and many devices will respond by
|
|
providing their DCC address, which will be added to the table.</p>
|
|
<p>Once you have the report back from the layout, click [Close Broadcast Session] to exit the
|
|
general access.<br>
|
|
Click on one of the rows to copy the address to the top, and click [Start Module Programming]
|
|
to continue.</p>
|
|
|
|
<h2>Direct Mode</h2>
|
|
|
|
<p>Check the 'Direct Mode' checkbox to access 16 state buttons to set LEDs etc. on
|
|
Uhlenbrock Track-Control items.</p>
|
|
|
|
<h2>LNCV Decoder definitions</h2>
|
|
|
|
With an LNCV Module Programming session (to a specific device) running, you can use the
|
|
Roster entry programming panes for more advanced (and accessible) configuration. Easily
|
|
switch to DecoderPro Roster either by clicking the [Program] button in the table or manually
|
|
open the entry for the module in your Roster entries list.<br>
|
|
Go to the "LNCV (Booster) Configuration" tab to read and write options supported by the
|
|
device.
|
|
<p>Anyone interested in writing their own LNCV decoder definitions in JMRI, please note that
|
|
in the definition programming mode should be defined as
|
|
<code><mode>LOCONETLNCVMODE</mode></code>.<br>
|
|
The Article part (item 1. in the list above) must be defined in the definition as the<br>
|
|
<code><model productID="5033" /></code>. To process LNCV commands in JMRI
|
|
LnOpsProgrammer, elements 1. and 3. are combined into a single CV number as
|
|
"part_1.part_3".<br>
|
|
For example CV6 in the DR5033 is defined as:<br>
|
|
<code><variable CV="5033.6" readOnly="yes" item="Temperature"></code></p>
|
|