<!DOCTYPE html>
|
|
<html lang="en">
|
|
<head>
|
|
<meta name="generator" content="HTML Tidy for HTML5 for Apple macOS version 5.8.0">
|
|
<title>JMRI: Configure Digitrax SE8c</title>
|
|
<meta name="author" content="Bob Jacobsen">
|
|
<meta name="keywords" content="JMRI help configure loconet SE8C">
|
|
<!--#include virtual="/help/en/parts/Style.shtml" -->
|
|
</head>
|
|
<body>
|
|
<!--#include virtual="/help/en/parts/Header.shtml" -->
|
|
|
|
<div id="mBody">
|
|
<div id="mainContent" class="no-sidebar">
|
|
|
|
<h1>Configure Digitrax SE8c</h1>
|
|
|
|
<a href="SE8cConfigTool.png"><img src="SE8cConfigTool.png" alt=
|
|
"SE8c Configuration Tool Screen Capture" style="float:right; margin: 5px;"></a>
|
|
|
|
<p>The JMRI SE8c programming tool lets you configure the internal options of a Digitrax SE8c
|
|
Signaling Decoder Board directly from your computer.</p>
|
|
|
|
<p>To open this tool from the JMRI pane select the LocoNet menu and then find the tool on the
|
|
list.</p>
|
|
|
|
<p>To use it, you put the address of an SE8c board in the text field and click "Read from
|
|
SE8c". The tool will read back the current state of the various options, and set the check
|
|
boxes to correspond to their current values.</p>
|
|
|
|
<p>You can then, if you wish, change the checkboxes and click "Write to SE8c" to make your
|
|
changes permanent.</p>
|
|
|
|
<p>The tool relies upon each SE8C board to have a unique "Board ID" (Board Address) in order
|
|
to configure each device individually. While it is possible to change the Board ID number
|
|
using JMRI, it cannot be done using this tool due to limitations of the SE8C design. Instead,
|
|
follow the instructions found <a href=
|
|
"../../../../../html/hardware/loconet/Digitrax.shtml#deviceBoardId">here</a>, but you must
|
|
consult the SE8C manual and modify the JMRI-based process to suit the SE8C device's buttons,
|
|
button press time, and lamp flashes.</p>
|
|
|
|
<h2>Limitations</h2>
|
|
|
|
<ul>
|
|
<li>Because of the way the SE8c board works, this tool can't change the basic address of
|
|
the unit. It is possible to change the Board ID number using JMRI by following the
|
|
instructions found <a href=
|
|
"../../../../../html/hardware/loconet/Digitrax.shtml#deviceBoardId">here</a>. Note that it
|
|
is necessary to consult the SE8C manual and modify the JMRI-based process shown at the link
|
|
above to suit the SE8C's buttons, button press time, and lamp flashes.
|
|
</li>
|
|
|
|
<li>The SE8c can be configured to send Sensor status on the LocoNet in response to a "track
|
|
power on" command. The SE8c does not send Turnout status in response to a "track power on"
|
|
command.</li>
|
|
|
|
<li>This tool is able to access SE8c boards with addresses between 1 and 36. Users are
|
|
advised to avoid using the factory default board address (board address 1) as it will be
|
|
difficult to program new boards with unique data if any in-service board is using the
|
|
factory default board address.</li>
|
|
</ul>
|
|
|
|
<h2>See Also</h2>
|
|
|
|
<p>Documentation for the SE8c can be found at the <a href=
|
|
"http://www.digitrax.com/tsd/product/SE8C/">Digitrax Web Site</a>.</p>
|
|