Files
JIMRI/xml/decoders/Uhlenbrock_76560.xml
2026-06-17 14:00:51 +02:00

148 lines
9.0 KiB
XML

<?xml version="1.0" encoding="utf-8"?>
<?xml-stylesheet type="text/xsl" href="../XSLT/decoder.xsl"?>
<!-- Copyright (C) JMRI 2014 All rights reserved -->
<!-- -->
<!-- JMRI is free software; you can redistribute it and/or modify it under -->
<!-- the terms of version 2 of the GNU General Public License as published -->
<!-- by the Free Software Foundation. See the "COPYING" file for a copy -->
<!-- of this license. -->
<!-- -->
<!-- JMRI is distributed in the hope that it will be useful, but WITHOUT -->
<!-- ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or -->
<!-- FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License -->
<!-- for more details. -->
<decoder-config xmlns:xi="http://www.w3.org/2001/XInclude" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="http://jmri.org/xml/schema/decoder-4-15-2.xsd">
<version author="Alain Le Marchand" version="1" lastUpdated="20140511"/>
<!-- Version 1 - Created from Uhlenbrock_76400.xml v2 (Alain Le Marchand) -->
<!-- WARNING: output names fully linked to function mapping include file - do not change independently -->
<decoder>
<family name="Multi-Protocol Decoder" mfg="Uhlenbrock Elektronik" lowVersionID="9" comment="Decoders not sorted (necessarily) in numerical order">
<model model="76560" numOuts="9" numFns="14" maxMotorCurrent="1.2A" formFactor="HO" connector="PluX22" productID="76560" comment="HO-Scale, IntelliDrive Deluxe with PluX22 plug and RailCom(R)">
<output name="1" label="F0(f)" connection="plug"/>
<output name="2" label="F0(r)" connection="plug"/>
<output name="3" label=". A1 ." connection="plug"/>
<output name="4" label=". A2 ." connection="plug"/>
<output name="5" label=". A3 ." connection="plug"/>
<output name="6" label=". A4 ." connection="plug"/>
<output name="7" label=". A5 ." connection="plug"/>
<output name="8" label=". A6 ." connection="plug"/>
<output name="9" label=". A7 ." connection="plug"/>
<output name="Shunting" label="mode"/>
<output name="Start/brake" label="inertia"/>
<size length="22" width="15" height="3.8" units="mm"/>
</model>
</family>
<programming direct="yes" paged="yes" register="yes" ops="yes"/>
<variables>
<xi:include href="http://jmri.org/xml/decoders/nmra/shortAndLongAddress.xml"/>
<xi:include href="http://jmri.org/xml/decoders/uhlenbrock/vStartHighMid-accelDecel.xml"/>
<variable item="Decoder Version" CV="7" readOnly="yes" default="9">
<decVal/>
<label>Manufacturer Version No: </label>
<label xml:lang="it">Versione Decoder: </label>
<label xml:lang="fr">Version décodeur: </label>
<label xml:lang="de">Decoder Version: </label>
<label xml:lang="nl">Versie van decoder: </label>
</variable>
<variable item="Manufacturer" CV="8" readOnly="yes" default="85">
<decVal/>
<label>Manufacturer ID: </label>
<label xml:lang="it">ID Costruttore: </label>
<label xml:lang="fr">ID constructeur: </label>
<label xml:lang="de">Hersteller ID: </label>
<label xml:lang="nl">Fabrikant-ID: </label>
</variable>
<!-- CV12 - see below with CV49 -->
<xi:include href="http://jmri.org/xml/decoders/uhlenbrock/cv13analogfunction.xml"/>
<xi:include href="http://jmri.org/xml/decoders/nmra/consistAddrDirection.xml"/>
<xi:include href="http://jmri.org/xml/decoders/nmra/cv29direction.xml"/>
<xi:include href="http://jmri.org/xml/decoders/nmra/cv29speedSteps.xml"/>
<xi:include href="http://jmri.org/xml/decoders/uhlenbrock/cv29analog.xml"/>
<xi:include href="http://jmri.org/xml/decoders/nmra/cv29RailCom.xml"/>
<xi:include href="http://jmri.org/xml/decoders/nmra/cv29table3-28.xml"/>
<!-- Include function mapping -->
<xi:include href="http://jmri.org/xml/decoders/uhlenbrock/functionmap7outputs.xml"/>
<!-- End function mapping -->
<xi:include href="http://jmri.org/xml/decoders/uhlenbrock/cv47.48trim.xml"/>
<!-- CV49 Uhlenbrock decoder configuration - common bits -->
<xi:include href="http://jmri.org/xml/decoders/uhlenbrock/cv49common.xml"/>
<!-- CV49 bits 3-4 moved to CV12 in this decoder -->
<xi:include href="http://jmri.org/xml/decoders/uhlenbrock/cv12dataformat.xml"/>
<!-- CV49 specific bits for this decoder-->
<xi:include href="http://jmri.org/xml/decoders/uhlenbrock/cv49braking.xml"/>
<xi:include href="http://jmri.org/xml/decoders/uhlenbrock/cv51analog.xml"/>
<variable item="EMF Option 1" CV="53" default="35">
<decVal max="63"/>
<label>Repetition rate</label>
<label xml:lang="de">Wiederholrate der Motorregelung</label>
<tooltip>Lower if the locomotive does not run smoothly - Value * 53 micro.s</tooltip>
<tooltip xml:lang="de">verkleinern, wenn Lok ungleichmäßig läuft - Wert * 53 micro.S</tooltip>
</variable>
<variable item="EMF Static Config" CV="54" default="20">
<decVal max="63"/>
<label>Motor regulation P Constant</label>
<label xml:lang="de">Motorregelung P-Konstante</label>
</variable>
<variable item="EMF Dynamic Config" CV="55" default="10">
<decVal max="63"/>
<label>Motor regulation I Constant</label>
<label xml:lang="de">Motorregelung I-Konstante</label>
</variable>
<variable item="EMF Control Reference" CV="56" default="32">
<decVal max="63"/>
<label>Control Reference</label>
<label xml:lang="de">Regelreferenz</label>
<tooltip>Lower Value if top speed too low, Raise Value if Speed at Step 1 too fast</tooltip>
<tooltip xml:lang="de">verkleinern, wenn Höchstgeschwindigkeit zu geringer - vergrößern, wenn geschwindigkeit Schritt 1 zu schnell</tooltip>
</variable>
<variable item="EMF Droop Config" CV="57" default="2">
<decVal max="63"/>
<label>Motor regulation D Constant</label>
<label xml:lang="de">Motorregelung D-Konstante</label>
</variable>
<variable item="EMF Option 2" CV="58" default="12">
<decVal max="63"/>
<label>Time slot for AD measurement</label>
<label xml:lang="de">Zeitschlitz für AD Wandlermessung</label>
<tooltip>Increase if loc does not run smoothly at low speeds - Decrease if the top speed is too low after CV53 has been lowered</tooltip>
<tooltip xml:lang="de">vergrößern, wenn Lok bei geringer Geschwindigkeit ungleichmäßig läuft; verkleinern, wenn bei heruntergesetztem CV 53 Höchstgeschwindigkeit der Lok zu gering ist</tooltip>
</variable>
<variable item="Short circuit supervision" CV="60" default="9" readOnly="yes">
<decVal max="9"/>
<label>Motor Short circuit supervision</label>
<label xml:lang="de">Kurzschlussüberwachung Motor</label>
<tooltip>Do not change! 0=deactivated - 9=activated</tooltip>
</variable>
<variable item="Shutdown Temperature" CV="61" default="32" readOnly="yes">
<decVal/>
<label>Shutdown Temperature</label>
<label xml:lang="de">Abschalttemperatur</label>
<tooltip>in °C, different with each decoder</tooltip>
</variable>
<variable item="Lights Short circuit supervision" CV="62" default="249" readOnly="yes">
<decVal max="255"/>
<label>Lights Short circuit supervision</label>
<label xml:lang="de">Kurzschlussüberwachung Licht</label>
<tooltip>Do not change! 0=deactivated - 249=activated</tooltip>
</variable>
<variable item="End braking speed" CV="64" default="30">
<decVal/>
<label>End braking speed</label>
<label xml:lang="de">Geschw. am Ende Bremsstrecke</label>
<label xml:lang="nl">Snelheid aan einde Remsectie</label>
<tooltip>Valid when CV49 Bit 2=1 (Braking end) and Bit 7=1 (Braking analog)</tooltip>
</variable>
<xi:include href="http://jmri.org/xml/decoders/uhlenbrock/cv65.66registers.xml"/>
<xi:include href="http://jmri.org/xml/decoders/nmra/cv67speedTableBasic.xml"/>
<xi:include href="http://jmri.org/xml/decoders/uhlenbrock/cv107.108indepOutputs.xml"/>
<xi:include href="http://jmri.org/xml/decoders/uhlenbrock/cv115lissy.xml"/>
<!-- CVs 109 - 111, 116 - 123 -->
<xi:include href="http://jmri.org/xml/decoders/uhlenbrock/optionVars7outputs.xml"/>
<xi:include href="http://jmri.org/xml/decoders/uhlenbrock/cv124.129coupling.xml"/>
<xi:include href="http://jmri.org/xml/decoders/uhlenbrock/cv130.134smoke.xml"/>
</variables>
<xi:include href="http://jmri.org/xml/decoders/uhlenbrock/factReset.xml"/>
</decoder>
<xi:include href="http://jmri.org/xml/decoders/uhlenbrock/PaneUhlenbrock.xml"/>
</decoder-config>