# Script Programs DCC Specialties - BlockWatcher
# http://www.dccspecialties.com
#
# Script by Brett Scott
# Version 1.50 07/27/2014
# mgbrrclub@gmail.com or info@mgbrr.org and www.mgbrr.org
#
# Many Thanks to Bob Jacobsen and Everyone who Contributes to JMRI.
#
# Script should work for any DCC System that supports Ops Mode Programming or
# Programming on Mainline. (Digitrax, NEC, MRC, Lenz)
#
# You should copy this file to ProgramBlockWatcher????.py Replacing ????
# with the Primary Address of your BlockWatcher. You should keep this file
# for backup, and future tweaking and programming.
#
# Each group of program lines is documented. To execute a group of statements, remove
# the # from the beginning of the proceeding program lines. Edit the program lines
# to include necessary information for your BlockWatcher.
#
# Be Sure to remove the # from the "self.waitMsec(750)" line. This gives the BlockWatcher sufficient
# time to process each preceding command.
#
# This script uses Locomotive Address 9983. Please make sure there is NO Locomotive number 9983
# on your layout while running this script. This script will reprogram several of its CV's.
#
# Instructions
# 1. Turn Off Track Power - Use a Throttle or JMRI to do this.
# 2. Move the Program Jumper J3 from either [J3-2 J3-3] or [J3-3 J3-4] To [J3-1 J3-2](Program Mode)
# 3. Turn On Track Power - Again, Use a Throttle or JMRI.
# 4. VERY IMPORTANT - Wait 30 to 45 Seconds.
# 5. In JMRI DecoderPro, Go to Panels > Run Script. Select the file that corresponds
# to the BlockWatcher you are programming. Note - Do not have the file open in an editor.
#
# Important - This script can take 2 to 6 seconds to run. This depends on the number of
# CV's and addresses being programmed.
#
# When the script is complete, a small message window should appear. Usually
# in the upper left corner of your screen.
#
# 6. Turn Off Track Power.
# 7. Move the program jumper J3 from [J3-1 J3-2] back to [J2-2 J2-3](Automatic Setting Leakage Current)
# or [J3-3 J3-4](Leakage Current Set with CV).
# 8. Turn Track Power On.
# 9. Test you BlockWatcher.
#
import jmri
import javax.swing
class setStartup(jmri.jmrit.automat.AbstractAutomaton) :
def init(self):
return
def handle(self):
# Next Two Lines - Reset BlockWatcher to Factory Defaults
addressedProgrammers.getAddressedProgrammer(True, 9983).writeCV("63", 42, None)
self.waitMsec(750) # time is in milliseconds
# Next Two Lines - Point BlockWatcher to Receive Primary Address, Not Necessary, However, good practice.
addressedProgrammers.getAddressedProgrammer(True, 9983).writeCV("63", 0, None)
self.waitMsec(750)
# Next Two Lines - Set Primary Address - Change 1234 to Address Desired
turnouts.provideTurnout("1234").setState(CLOSED)
self.waitMsec(750)
# Last Two Lines of this Group - CV53 - Delay in Milliseconds
# Sets the delay in milliseconds that the block current exceeds the trip level
# before the J4 output will turn on. It is also the turn-off delay for the amount
# of time the block current is below the trip level before the J4 output turns
# off. The default value is 32 ms.
# addressedProgrammers.getAddressedProgrammer(True, 9983).writeCV("53", 32, None)
# self.waitMsec(750)
# Last Two Lines of this Group - CV54 - Average Unoccupied Block Current
# This CV sets the average value of the block current when it is unoccupied.
# The J4 turn on threshold is 3 + CV54 + CV55. The turn off threshold is 3 + CV54.
# The scaling value is 0.534 mA per bit. The default is 0, which will result in
# a trip current of about 2 mA. The maximum value is 254 CV55 3.
# This sets the maximum trip current to about 130 mA.
# (With J3 on pins 2-3 this value is set each time power is applied to the detector.)
# addressedProgrammers.getAddressedProgrammer(True, 9983).writeCV("54", 0, None)
# self.waitMsec(750)
# Last Two Lines of this Group - CV55 - Hysterisis Between On and Off
# Sets the hysterisis between on and off (see CV54). Its default value is 1.
# This keeps the detector fromfluttering when the detected current is near the switching point.
# addressedProgrammers.getAddressedProgrammer(True, 9983).writeCV("55", 1, None)
# self.waitMsec(750)
javax.swing.JFrame("Programming Complete!").show()
return
setStartup().start()