LOCONETLNCVMODEEnter as decimal value (0-65534)Turn on automatically following a short circuit in 3 ms steps. The standard value is equivalent to approx. 3/4 of a second (750 ms)Automatisches Einschalten nach einem Kurzschluss im drei Ms Takt. Der Standardwert entspricht ca. einer 3/4 Sekunde (750 ms)Activation automatique si court-circuit en étapes de 3 ms. La valeur standard équivaut à env. 3⁄4 de seconde (750 ms)Wachttijd tot de herstart na kortsluiting. De standaardwaarde ca. 3/4 seconde (750 ms). (instellen in stappen van 3 milliseconde)Short detection delay in 0.6 sec steps. Manual advises not to change.Einschaltreaktionszeit im 0,6 s Takt. Handbuch warnt vor Änderung.Le temps de réaction en étapes de 0,6 s.Inschakelvertraging (stappen van 0,6 s). Advies om niet te wijzigenSwitch on delay in 0.5 sec stepsEinschaltreaktionszeit im 0,5 s TaktLe temps de réaction en étapes de 0,5 s.Inschakelvertraging (in stappen van 0,5 s)Choose and write...Kies optie en schrijf...Paired for turnout control2-Positie Servo'sPaired alternating outputs on/offPer 2 wisselend aan/uitSeparate on/off outputsIndividueel aan/uitFactory ResetZet terug naar fabrieksinstellingZurück nach WerkseinstellungenAll Outputs DeactivatedAlle uitgangen inactiefAlle Ausgänge InaktivConfigures all outputs (from start address) or Module ResetKonfiguriert Modul für alle Ausgänge (von Anfangsadresse):Kies instelling voor alle uitgangen (vanaf startadres):Start Address for Module Setting (1-2048)Blink rate Generator #1 for outputs 1-8Blink rate generator #1 for outputs 9-16Blink rate Generator #1 for outputs 17-20Blink rate Generator #2 for outputs 1-8Blink rate Generator #2 for outputs 9-16Blink rate Generator #2 for outputs 17-20Intended for verification only, set options under each output.Damped (slow) on/off transitionDamped (slow) on/off transitionDamped (slow) on/off transitionDamped (slow) on/off transitionDamped (slow) on/off transitionDamped (slow) on/off transitionDamped (slow) on/off transitionDamped (slow) on/off transitionDamped (slow) on/off transitionDamped (slow) on/off transitionDamped (slow) on/off transitionDamped (slow) on/off transitionDamped (slow) on/off transitionDamped (slow) on/off transitionDamped (slow) on/off transitionDamped (slow) on/off transitionIntended for verification only, set options under each output.Damped (slow) on/off transitionDamped (slow) on/off transitionDamped (slow) on/off transitionDamped (slow) on/off transitionDamped switching Overlap in 32 ms incrementsType of signal head connected to this group of outputsAddress of searchlight signal (1-2048)Type of signal head connected to this group of outputsAddress of searchlight signal (1-2048)Type of signal head connected to this group of outputsAddress of searchlight signal (1-2048)Type of signal head connected to this group of outputsAddress of searchlight signal (1-2048)Type of signal head connected to this group of outputsAddress of searchlight signal (1-2048)Command to turn output 1 OnAddress to switch output 1 On (1-2048)Command to turn output 2 OnAddress to switch output 2 On (1-2048)Command to turn output 3 OnAddress to switch output 3 On (1-2048)Command to turn output 4 OnAddress to switch output 4 On (1-2048)Command to turn output 5 OnAddress to switch output 5 On (1-2048)Command to turn output 6 OnAddress to switch output 6 On (1-2048)Command to turn output 7 OnAddress to switch output 7 On (1-2048)Command to turn output 8 OnAddress to switch output 8 On (1-2048)Command to turn output 9 OnAddress to switch output 9 On (1-2048)Command to turn output 10 OnAddress to switch output 10 On (1-2048)Command to turn output 11 OnAddress to switch output 11 On (1-2048)Command to turn output 12 OnAddress to switch output 12 On (1-2048)Command to turn output 13 OnAddress to switch output 13 On (1-2048)Command to turn output 14 OnAddress to switch output 14 On (1-2048)Command to turn output 15 OnAddress to switch output 15 On (1-2048)Command to turn output 16 OnAddress to switch output 16 On (1-2048)Command to turn output 17 OnAddress to switch output 17 On (1-2048)Command to turn output 18 OnAddress to switch output 18 On (1-2048)Command to turn output 19 OnAddress to switch output 19 On (1-2048)Command to turn output 20 OnAddress to switch output 20 On (1-2048)Command to turn output 1 OffAddress to switch output 1 Off (1-2048)Command to turn output 2 OffAddress to switch output 2 Off (1-2048)Command to turn output 3 OffAddress to switch output 3 Off (1-2048)Command to turn output 4 OffAddress to switch output 4 Off (1-2048)Command to turn output 5 OffAddress to switch output 5 Off (1-2048)Command to turn output 6 OffAddress to switch output 6 Off (1-2048)Command to turn output 7 OffAddress to switch output 7 Off (1-2048)Command to turn output 8 OffAddress to switch output 8 Off (1-2048)Command to turn output 9 OffAddress to switch output 9 Off (1-2048)Command to turn Output 10 OffAddress to switch output 10 Off (1-2048)Command to turn output 11 OffAddress to switch output 11 Off (1-2048)Command to turn output 12 OffAddress to switch output 12 Off (1-2048)Command to turn output 13 OffAddress to switch output 13 Off (1-2048)Command to turn output 14 OffAddress to switch output 14 Off (1-2048)Command to turn output 15 OffAddress to switch output 15 Off (1-2048)Command to turn output 16 OffAddress to switch output 16 Off (1-2048)Command to turn output 17 OffAddress to switch output 17 Off (1-2048)Command to turn output 18 OffAddress to switch output 18 Off (1-2048)Command to turn output 19 OffAddress to switch output 19 Off (1-2048)Command to turn output 20 OffAddress to switch output 20 Off (1-2048)Switching mode of output 1Duration of momentary output 1 in 50 ms steps (1-255, 0=continuous)Switching mode of output 2Duration of momentary output 2 in 50 ms steps (1-255, 0=continuous)Switching mode of output 3Duration of momentary output 3 in 50 ms steps (1-255, 0=continuous)Switching mode of output 4Duration of momentary output 4 in 50 ms steps (1-255, 0=continuous)Switching mode of output 5Duration of momentary output 5 in 50 ms steps (1-255, 0=continuous)Switching mode of output 6Duration of momentary output 6 in 50 ms steps (1-255, 0=continuous)Switching mode of output 7Duration of momentary output 7 in 50 ms steps (1-255, 0=continuous)Switching mode of output 8Duration of momentary output 8 in 50 ms steps (1-255, 0=continuous)Switching mode of output 9Duration of momentary output 9 in 50 ms steps (1-255, 0=continuous)Switching mode of output 10Duration of momentary output 10 in 50 ms steps (1-255, 0=continuous)Switching mode of output 11Duration of momentary output 11 in 50 ms steps (1-255, 0=continuous)Switching mode of output 12Duration of momentary output 12 in 50 ms steps (1-255, 0=continuous)Switching mode of output 13Duration of momentary output 13 in 50 ms steps (1-255, 0=continuous)Switching mode of output 14Duration of momentary output 14 in 50 ms steps (1-255, 0=continuous)Switching mode of output 15Duration of momentary output 15 in 50 ms steps (1-255, 0=continuous)Switching mode of output 16Duration of momentary output 16 in 50 ms steps (1-255, 0=continuous)Switching mode of output 17Duration of momentary output 17 in 50 ms steps (1-255, 0=continuous)Switching mode of output 18Duration of momentary output 18 in 50 ms steps (1-255, 0=continuous)Switching mode of output 19Duration of momentary output 19 in 50 ms steps (1-255, 0=continuous)Switching mode of output 20Duration of momentary output 20 in 50 ms steps (1-255, 0=continuous)LNCV ModuleLNCV ModulLNCV ModuleLNCV Output ConfigurationLNCV AusgangskonfigurationLNCV Uitgangen Instellen