LOCONETLNCVMODE Enter as decimal value (0-65534) Turn on automatically following a short circuit in 3 ms steps. The standard value is equivalent to approx. 3/4 of a second (750 ms) Automatisches Einschalten nach einem Kurzschluss im drei Ms Takt. Der Standardwert entspricht ca. einer 3/4 Sekunde (750 ms) Activation automatique si court-circuit en étapes de 3 ms. La valeur standard équivaut à env. 3⁄4 de seconde (750 ms) Wachttijd tot de herstart na kortsluiting. De standaardwaarde ca. 3/4 seconde (750 ms). (instellen in stappen van 3 milliseconde) Short detection delay in 0.6 sec steps. Manual advises not to change. Einschaltreaktionszeit im 0,6 s Takt. Handbuch warnt vor Änderung. Le temps de réaction en étapes de 0,6 s. Inschakelvertraging (stappen van 0,6 s). Advies om niet te wijzigen Switch on delay in 0.5 sec steps Einschaltreaktionszeit im 0,5 s Takt Le temps de réaction en étapes de 0,5 s. Inschakelvertraging (in stappen van 0,5 s) Choose and write... Kies optie en schrijf... Paired for turnout control 2-Positie Servo's Paired alternating outputs on/off Per 2 wisselend aan/uit Separate on/off outputs Individueel aan/uit Factory Reset Zet terug naar fabrieksinstelling Zurück nach Werkseinstellungen All Outputs Deactivated Alle uitgangen inactief Alle Ausgänge Inaktiv Configures all outputs (from start address) or Module Reset Konfiguriert Modul für alle Ausgänge (von Anfangsadresse): Kies instelling voor alle uitgangen (vanaf startadres): Start Address for Module Setting (1-2048) Blink rate Generator #1 for outputs 1-8 Blink rate generator #1 for outputs 9-16 Blink rate Generator #1 for outputs 17-20 Blink rate Generator #2 for outputs 1-8 Blink rate Generator #2 for outputs 9-16 Blink rate Generator #2 for outputs 17-20 Intended for verification only, set options under each output. Damped (slow) on/off transition Damped (slow) on/off transition Damped (slow) on/off transition Damped (slow) on/off transition Damped (slow) on/off transition Damped (slow) on/off transition Damped (slow) on/off transition Damped (slow) on/off transition Damped (slow) on/off transition Damped (slow) on/off transition Damped (slow) on/off transition Damped (slow) on/off transition Damped (slow) on/off transition Damped (slow) on/off transition Damped (slow) on/off transition Damped (slow) on/off transition Intended for verification only, set options under each output. Damped (slow) on/off transition Damped (slow) on/off transition Damped (slow) on/off transition Damped (slow) on/off transition Damped switching Overlap in 32 ms increments Type of signal head connected to this group of outputs Address of searchlight signal (1-2048) Type of signal head connected to this group of outputs Address of searchlight signal (1-2048) Type of signal head connected to this group of outputs Address of searchlight signal (1-2048) Type of signal head connected to this group of outputs Address of searchlight signal (1-2048) Type of signal head connected to this group of outputs Address of searchlight signal (1-2048) Command to turn output 1 On Address to switch output 1 On (1-2048) Command to turn output 2 On Address to switch output 2 On (1-2048) Command to turn output 3 On Address to switch output 3 On (1-2048) Command to turn output 4 On Address to switch output 4 On (1-2048) Command to turn output 5 On Address to switch output 5 On (1-2048) Command to turn output 6 On Address to switch output 6 On (1-2048) Command to turn output 7 On Address to switch output 7 On (1-2048) Command to turn output 8 On Address to switch output 8 On (1-2048) Command to turn output 9 On Address to switch output 9 On (1-2048) Command to turn output 10 On Address to switch output 10 On (1-2048) Command to turn output 11 On Address to switch output 11 On (1-2048) Command to turn output 12 On Address to switch output 12 On (1-2048) Command to turn output 13 On Address to switch output 13 On (1-2048) Command to turn output 14 On Address to switch output 14 On (1-2048) Command to turn output 15 On Address to switch output 15 On (1-2048) Command to turn output 16 On Address to switch output 16 On (1-2048) Command to turn output 17 On Address to switch output 17 On (1-2048) Command to turn output 18 On Address to switch output 18 On (1-2048) Command to turn output 19 On Address to switch output 19 On (1-2048) Command to turn output 20 On Address to switch output 20 On (1-2048) Command to turn output 1 Off Address to switch output 1 Off (1-2048) Command to turn output 2 Off Address to switch output 2 Off (1-2048) Command to turn output 3 Off Address to switch output 3 Off (1-2048) Command to turn output 4 Off Address to switch output 4 Off (1-2048) Command to turn output 5 Off Address to switch output 5 Off (1-2048) Command to turn output 6 Off Address to switch output 6 Off (1-2048) Command to turn output 7 Off Address to switch output 7 Off (1-2048) Command to turn output 8 Off Address to switch output 8 Off (1-2048) Command to turn output 9 Off Address to switch output 9 Off (1-2048) Command to turn Output 10 Off Address to switch output 10 Off (1-2048) Command to turn output 11 Off Address to switch output 11 Off (1-2048) Command to turn output 12 Off Address to switch output 12 Off (1-2048) Command to turn output 13 Off Address to switch output 13 Off (1-2048) Command to turn output 14 Off Address to switch output 14 Off (1-2048) Command to turn output 15 Off Address to switch output 15 Off (1-2048) Command to turn output 16 Off Address to switch output 16 Off (1-2048) Command to turn output 17 Off Address to switch output 17 Off (1-2048) Command to turn output 18 Off Address to switch output 18 Off (1-2048) Command to turn output 19 Off Address to switch output 19 Off (1-2048) Command to turn output 20 Off Address to switch output 20 Off (1-2048) Switching mode of output 1 Duration of momentary output 1 in 50 ms steps (1-255, 0=continuous) Switching mode of output 2 Duration of momentary output 2 in 50 ms steps (1-255, 0=continuous) Switching mode of output 3 Duration of momentary output 3 in 50 ms steps (1-255, 0=continuous) Switching mode of output 4 Duration of momentary output 4 in 50 ms steps (1-255, 0=continuous) Switching mode of output 5 Duration of momentary output 5 in 50 ms steps (1-255, 0=continuous) Switching mode of output 6 Duration of momentary output 6 in 50 ms steps (1-255, 0=continuous) Switching mode of output 7 Duration of momentary output 7 in 50 ms steps (1-255, 0=continuous) Switching mode of output 8 Duration of momentary output 8 in 50 ms steps (1-255, 0=continuous) Switching mode of output 9 Duration of momentary output 9 in 50 ms steps (1-255, 0=continuous) Switching mode of output 10 Duration of momentary output 10 in 50 ms steps (1-255, 0=continuous) Switching mode of output 11 Duration of momentary output 11 in 50 ms steps (1-255, 0=continuous) Switching mode of output 12 Duration of momentary output 12 in 50 ms steps (1-255, 0=continuous) Switching mode of output 13 Duration of momentary output 13 in 50 ms steps (1-255, 0=continuous) Switching mode of output 14 Duration of momentary output 14 in 50 ms steps (1-255, 0=continuous) Switching mode of output 15 Duration of momentary output 15 in 50 ms steps (1-255, 0=continuous) Switching mode of output 16 Duration of momentary output 16 in 50 ms steps (1-255, 0=continuous) Switching mode of output 17 Duration of momentary output 17 in 50 ms steps (1-255, 0=continuous) Switching mode of output 18 Duration of momentary output 18 in 50 ms steps (1-255, 0=continuous) Switching mode of output 19 Duration of momentary output 19 in 50 ms steps (1-255, 0=continuous) Switching mode of output 20 Duration of momentary output 20 in 50 ms steps (1-255, 0=continuous) LNCV Module LNCV Modul LNCV Module LNCV Output Configuration LNCV Ausgangskonfiguration LNCV Uitgangen Instellen