2016 JMRI Michael Mosher Alain Le Marchand James Exler 1 2016-05-26 MM New file 1.1 2016-06-04 ALM added CV126 coupler sound selection, fixed mask for CV122 Grade-Crossing Bell Enable 1.2 2018-02-18 ALM fixed CV range to 255 for CV194, Moved all Advanced Motor control to Motor pane 2.0 2016-05-26 MM For Tsunami2 defintions Moved some CVs to Econami files, as not in Tsuname2, so that this file can be used for Tsunami2 as well 2.1 2016-06-04 ALM Move Light Effect CVs to separate file, New enums for CV247 2.2 2018-02-18 MM CV57 and 58 bit 6 and 7 set to 1 2.3 2016-06-04 ALM Move CV 241-242 (analog mode F13-28) and CV 245-246 (consist F13-28) to separate files, for use by OEM SoundCar files. Tooltip for CV 218 fixed based on latest Econami manual 2.4 2016-06-04 ALM Specific UserID with tooltip indicating version number, from SoundTraxx Product Identification guide Rev.B 3 2016-06-04 ALM Moved CV1.297 and above (Extended Function Map) to separate file, to accomodate Econami UK specifics -> ECOCVFnMap.xml Specific CV for UK decoders using include/exclude: CVs: 126, 130, 150, 193, 194, 197, 198 4 2022-08-15 JE edit the CV49-58 FX text to match TSU2 values. chg CV63 name to Dimmer Level. rev CV215 tool tip and range display 5 2023-10-09 MM productID change for 11 bit Soundtraxx ID 5 2024-01-04 MM update CV256 <html>When loco has stopped and all functions are turned off, sound effects will turn <br>off automatically after timeout period has elapsed. Set to zero to disable. </html> <html>Adjust the motor response following a momentary power glitch <br>0 or 128 = Disabled <br>1-127 = Absolute Limiting (will return to this speed step) <br>129-255 = Proportional Limiting (a percentage of set speed) </html> The selected bell to ring during the crossing-timer countdown when Grade-Crossing Logic is activated <html>The selected bell to ring during the crossing-timer countdown <br> when Grade-Crossing Logic is activated <br>Not aplicable for UK: The bell is disabled in UK decoders. </html> Medium coupler Heavy coupler Link-and-pin Determine the coupler release sound effect activated by the coupler function Medium coupler Heavy coupler Link-and-pin Buffers Determine the coupler release sound effect activated by the coupler function Coupler release activated when function is turned on Coupler release activated when function is turned off Not included in Econami software releases prior to version 1.3 Specifies the throttle speed step where the automatic bell will first turn on <html>Specifies the throttle speed step where the automatic bell will first turn on<br>Bell disabled by default for UK decoders</html> Set the duration in seconds that elapses from the time the bell sound effect is automatically turned on to the time it is turned off <html>Set the duration in seconds that elapses from the time the bell sound effect is automatically turned on to the time it is turned off<br>Bell disabled by default for UK decoders</html> Disabled 1 slam 2 slams 3 slams 4 slams 5 slams 6 slams 7 slams 8 slams 9 slams 10 slams 11 slams 12 slams 13 slams 14 slams 15 slams Enables the Automatic Bell in Analog Mode <html>Enables the Automatic Bell in Analog Mode<br>Bell disabled by default for UK decoders</html> Enables the Automatic Bell in Digital Mode <html>Enables the Automatic Bell in Digital Mode<br>Bell disabled by default for UK decoders</html> Sets the status of automatic effects when moving in forward direction in analog power mode Sets the status of automatic effects when moving in reverse direction in analog power mode Sets the status of automatic effects when stopped in forward direction in analog power mode Sets the status of automatic effects when stopped in reverse direction in analog power mode Effect Function Controlled Effect Active moving forward Sets the status of automatic effects when moving in forward direction Effect Function Controlled Effect Active moving reverse Sets the status of automatic effects when moving in reverse direction Effect Function Controlled Effect Active stopped forward Sets the status of automatic effects when stopped in forward direction Effect Function Controlled Effect Active stopped reverse Sets the status of automatic effects when stopped in reverse direction E-Brake sound FX enabled ESTP effects enabled <html>Sets the status of automatic effects when in emergency stop.<br> Emergency Stop (ESTP) effects defined on Function Map</html> Most of the time this will be a value of 1 for SoundTraxx, but if you purchased the decoder installed in a model, the value will be different. Read decoder to get value Steam Diesel Electric UK Steam UK Diesel Read decoder to get value ECO-100 Steam ECO-100 Diesel ECO-100 Electric ECO-400 Steam ECO-400 Diesel ECO-400 Electric ECO-21P Steam ECO-21P Diesel ECO-21P Electric ECO-200 Steam ECO-200 Diesel ECO-200 Electric ECO-PNP Steam ECO-PNP Diesel ECO-PNP Electric TSU-1100 Steam TSU-2200 Steam TSU-21PNEM Steam TSU-4400 Steam TSU-1100 Diesel EMD TSU-1100 Diesel GE TSU-1100 Diesel ALCO TSU-1100 Diesel Baldwin & Others TSU-2200 Diesel EMD TSU-2200 Diesel GE TSU-2200 Diesel ALCO TSU-2200 Diesel Baldwin & Others TSU-21PNEM Diesel EMD TSU-21PNEM Diesel GE TSU-21PNEM Diesel ALCO TSU-21PNEM Diesel ALCO TSU-PNP Diesel EMD TSU-PNP Diesel GE TSU-PNP Diesel ALCO TSU-PNP Diesel Baldwin & Others TSU-4400 Diesel EMD TSU-4400 Diesel GE TSU-4400 Diesel ALCO TSU-4400 Diesel Baldwin & Others TSU-1100 Electric TSU-2200 Electric TSU-21PNEM Electric TSU-4400 Electric ECO-100 UK Steam ECO-100 UK Diesel ECO-200 UK Steam ECO-200 UK Diesel ECO-21PNEM UK Steam ECO-21PNEM UK Diesel ECO-400 UK Steam ECO-400 UK Diesel ECO-21PNEM Steam ECO-21PNEM Diesel TSU-1100 Diesel EMD-2 TSU-2200 Diesel EMD-2 TSU-21PNEM Diesel EMD-2 TSU-PNP Diesel EMD-2 TSU-4400 Diesel EMD-2 TSU-1100 Steam-2 TSU-2200 Steam-2 TSU-21PNEM Steam-2 TSU-4400 Steam-2 TSU-PNP8 Diesel EMD TSU-PNP8 Diesel GE TSU-PNP8 Diesel ALCO TSU-PNP8 Diesel Baldwin & Others TSU-PNP8 Diesel EMD-2 TSU-21PNEM8 Steam-2 TSU-21PNEM8 Diesel EMD TSU-21PNEM8 Diesel GE TSU-21PNEM8 Diesel ALCO TSU-21PNEM8 Diesel Baldwin & Others TSU-21PNEM8 Diesel EMD-2 TSU-21PNEM8 Electric TSU-KN1 Diesel TSU-N18 Steam-2 TSU-N18 Diesel EMD TSU-N18 Diesel GE TSU-N18 Diesel ALCO TSU-N18 Diesel Baldwin & Others TSU-N18 Diesel EMD-2 TSU-N18 Electric TSU-1100 Big Steam TSU-2200 Big Steam TSU-21PNEM8 Big Steam TSU-BH2 Steam-2 TSU-BH1 Diesel EMD TSU-BH1 Diesel GE TSU-BH1 Diesel ALCO BLU-2200 Steam-2 BLU-2200 EMD BLU-2200 GE BLU-2200 ALCO BLU-2200 Baldwin & Others BLU-2200 EMD-2 BLU-2200 Electric BLU-4408 Steam-2 BLU-4408 EMD BLU-4408 GE BLU-4408 ALCO BLU-4408 Baldwin & Others BLU-4408 EMD-2 BLU-4408 Electric BLU-PNP8 EMD BLU-PNP8 GE BLU-PNP8 ALCO BLU-PNP8 Baldwin & Others BLU-PNP8 EMD-2