2015 2018 2019 2020 2025 JMRI Bob Jacobsen Egbert Broerse 1 2015-08-12 BJ Initial version, test only 2 2018-04-26 EB Added Board and Ports panes, manual entry, still experimental 3 2019-04-10 EB Use compositeVal type values (ports 1-5 for now), updated decoder schema, add LocoServo, add LocoIO (PIC) versions up to 1.54, show only show supported options by model (note VersionID is not stored in CV7 of LocoIO), Opcode (only for port 1 for now) 4 2020-09-20 EB Changed address field labels hi/lo to function like 81/1 entry Use compositeVal type values (ports 1-16), add LocoBooster, Opcode1 and Opcode2 for ports 1-16, tested on actual hardware (read only), correct triple mask to store sensor address, LocoRCD(2) experimental 5 2025-01-15 EB Add support for GCA50(a)/GCA51 LocoIO boards from P. Giling. Requires firmware version 151/107 from github.com/silverailscolo/Arduino-GCA51/ because of version being stored in SV100, board config in SV0 like all LocoIO's. LOCONETSV1MODE Open the LocoNet Monitor to confirm the actual firmware version number (shown after you click Read Full Sheet) Choose from 0=none to 15=fast Choose from 0=none to 126 (~6,3 sec), 50ms per step Choose from 0=dim to 14=bright Default: unselected = Active Low Normal Normal Normaal How the ports on this board should operate 2-Position Servos 2-Positie Servo's 4-Position Servos 4-Positie Servo's How servo ports 5-12 on this board should operate LocoView display LocoView Anzeige LocoView-scherm Signals Signale Seinen What is connected to the board J4 connector? See LocoRCD2 manual. Fixed Vaste Code Alternating Wisselend Button sends alternating or fixed code, default: fixed Refresh Ports, default: unselected = off Use ports 1-4 for GO/STOP + status. Default: unselected = regular ports This provides the full address by combining the LocoIO Address lower and LocoIO Subaddress upper parts Message DSTL byte Message DSTH byte (editable in v1.46 and higher) Message DSTH byte (editable in v1.46 and higher, nor GCA51) Message DSTH byte (not editable before v1.46) Is this Port used for Occupancy N/Y (set by Type combo) Port 1 DCC Address (decimal, 1-4096) Port 1 DCC Block Occupancy Sensor Address (decimal, 1-4096) Port 1 RFID-RC522 Sensor Address (decimal, 1-4096) Port 1 Config, filled by ComboBox Port 1 Value1, created from address Port 1 Value2A part, filled by ComboBox + address high Port 1 Value2, filled via Value2A + address hi part Select... Auswählen... Selecteer... Special Input: Idle Speciale Ingang: Vrijloop Port 1-4 set as Special Type - IDLE Occupied will trigger train control, default: unselected = off Occupied will trigger train reversing direction, default: unselected = off Port1 Train Slow Down Delay (1-255) Port 1 Train Wait Time (1-255) Port1 Config lt 112 Port1 Config gt 0 Port 1 Opcode1 DCC Address (decimal, 1-2048) Port1 Config lt 112 Port1 Config gt 0 Port 1 Opcode1 OPC, filled by ComboBox Port1 Config lt 112 Port1 Config gt 0 Port 1 Opcode1 ARG1 (address lower bits 0-6) Port1 Config lt 112 Port1 Config gt 0 Port 1 Opcode1 Value2, filled by ComboBox + Address Port1 Config lt 112 Port1 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 1 Opcode1 OPC and ARG2 Port1 Config lt 112 Port1 Config gt 0 Port 1 Opcode2 DCC Address (decimal, 1-2048) Port1 Config lt 112 Port1 Config gt 0 Port 1 Opcode2 OPC, filled by ComboBox Port1 Config lt 112 Port1 Config gt 0 Port 1 Opcode2 ARG1, filled by ComboBox Port1 Config lt 112 Port1 Config gt 0 Port 1 Opcode2 ARG2, filled by ComboBox Port1 Config lt 112 Port1 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 1 Opcode2 OPC and ARG2 Is this Port used for Occupancy N/Y (set by Type combo) Port 2 DCC Address (decimal, 1-2048) Port 2 DCC Block Occupancy Sensor Address (decimal, 1-4096) Port 2 RFID-RC522 Sensor Address (decimal, 1-4096) Port 2 Config, filled by ComboBox Port 2 Value1 = (Address MINUS 1) & 127 Port 2 Value2A part, filled by ComboBox + address high Port 2 Value2, filled by ComboBox Select... Auswählen... Selecteer... Special Input: Go Speciale Ingang: Rijden Port 1-4 set as Special Type - GO Port2 Config lt 112 Port2 Config gt 0 Port 2 Opcode1 DCC Address (decimal, 1-2048) Port2 Config lt 112 Port2 Config gt 0 Port 2 Opcode1 OPC, filled by ComboBox Port2 Config lt 112 Port2 Config gt 0 Port 2 Opcode1 ARG1, filled by ComboBox Port2 Config lt 112 Port2 Config gt 0 Port 2 Opcode1 Value2, filled by ComboBox Port2 Config lt 112 Port2 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 2 Opcode1 OPC and ARG2 Port2 Config lt 112 Port2 Config gt 0 Port 2 Opcode2 DCC Address (decimal, 1-2048) Port2 Config lt 112 Port2 Config gt 0 Port 2 Opcode2 OPC, filled by ComboBox Port2 Config lt 112 Port2 Config gt 0 Port 2 Opcode2 ARG1, filled by ComboBox Port2 Config lt 112 Port2 Config gt 0 Port 2 Opcode2 ARG2, filled by ComboBox Port2 Config lt 112 Port2 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 2 Opcode2 OPC and ARG2 Is this Port used for Occupancy N/Y (set by Type combo) Port 3 DCC Address (decimal, 1-2048) Port 3 DCC Block Occupancy Sensor Address (decimal, 1-4096) Port 3 Config, filled by ComboBox Port 3 Value1 = (Address MINUS 1) & 127 Port 3 Value2A part, filled by ComboBox + address high Port 3 Value2, filled by ComboBox Occupied will trigger train control, default: unselected = off Occupied will trigger train reversing direction, default: unselected = off Port1 Train Slow Down Delay (1-255) Port 1 Train Wait Time (1-255) Select... Auswählen... Selecteer... Special Input: Stop Speciale Ingang: Stop Port 1-4 set as Special Type - STOP Port3 Config lt 112 Port3 Config gt 0 Port 3 Opcode1 DCC Address (decimal, 1-2048) Port3 Config lt 112 Port3 Config gt 0 Port 3 Opcode1 OPC, filled by ComboBox Port3 Config lt 112 Port3 Config gt 0 Port 3 Opcode1 ARG1, filled by ComboBox Port3 Config lt 112 Port3 Config gt 0 Port 3 Opcode1 Value2, filled by ComboBox Port3 Config lt 112 Port3 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 3 Opcode1 OPC and ARG2 Port3 Config lt 112 Port3 Config gt 0 Port 3 Opcode2 DCC Address (decimal, 1-2048) Port3 Config lt 112 Port3 Config gt 0 Port 3 Opcode2 OPC, filled by ComboBox Port3 Config lt 112 Port3 Config gt 0 Port 3 Opcode2 ARG1, filled by ComboBox Port3 Config lt 112 Port3 Config gt 0 Port 3 Opcode2 ARG2, filled by ComboBox Port3 Config lt 112 Port3 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 3 Opcode2 OPC and ARG2 Is this Port used for Occupancy N/Y (set by Type combo) Port 4 DCC Address (decimal, 1-2048) Port 4 DCC Block Occupancy Sensor Address (decimal, 1-4096) Port 4 Config, filled by ComboBox Port 4 Value1 = (Address MINUS 1) & 127 Port 4 Value2A part, filled by ComboBox + address high Port 4 Value2, filled by ComboBox Select... Auswählen... Selecteer... Special Output: Go/Stop Status Speciale Uitgang: Start/Stop Status Port 1-4 set as Special Type - GO/STOP Port4 Config lt 112 Port4 Config gt 0 Port 4 Opcode1 DCC Address (decimal, 1-2048) Port4 Config lt 112 Port4 Config gt 0 Port 4 Opcode1 OPC, filled by ComboBox Port4 Config lt 112 Port4 Config gt 0 Port 4 Opcode1 ARG1, filled by ComboBox Port4 Config lt 112 Port4 Config gt 0 Port 4 Opcode1 Value2, filled by ComboBox Port4 Config lt 112 Port4 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 4 Opcode1 OPC and ARG2 Port4 Config lt 112 Port4 Config gt 0 Port 4 Opcode2 DCC Address (decimal, 1-2048) Port4 Config lt 112 Port4 Config gt 0 Port 4 Opcode2 OPC, filled by ComboBox Port4 Config lt 112 Port4 Config gt 0 Port 4 Opcode2 ARG1, filled by ComboBox Port4 Config lt 112 Port4 Config gt 0 Port 4 Opcode2 ARG2, filled by ComboBox Port4 Config lt 112 Port4 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 4 Opcode2 OPC and ARG2 Is this Port used for Occupancy N/Y (set by Type combo) Port 5 DCC Address (decimal, 1-2048) Port 5 DCC Block Occupancy Sensor Address (decimal, 1-4096) Port 5 Config, filled by ComboBox Port 5 Value1 = (Address MINUS 1) & 127 Port 5 Value2A part, filled by ComboBox + address high Port 5 Value2, filled by ComboBox Occupied will trigger train control, default: unselected = off Occupied will trigger train reversing, default: unselected = off Port1 Train Slow Down Delay (1-255) Port 1 Train Wait Time (1-255) Output: Servo 1 (2/4 pos on tab Loco...) Uitgang: Servo (2/4 pos. op tab LocoIO) Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Port 5 Config and Value2 for servo connection Port5 Config lt 112 Port5 Config gt 0 Port 5 Opcode1 DCC Address (decimal, 1-2048) Port5 Config lt 112 Port5 Config gt 0 Port 5 Opcode1 OPC, filled by ComboBox Port5 Config lt 112 Port5 Config gt 0 Port 5 Opcode1 ARG1, filled by ComboBox Port5 Config lt 112 Port5 Config gt 0 Port 5 Opcode1 Value2, filled by ComboBox Port5 Config lt 112 Port5 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 5 Opcode1 OPC and ARG2 Port5 Config lt 112 Port5 Config gt 0 Port 5 Opcode2 DCC Address (decimal, 1-2048) Port5 Config lt 112 Port5 Config gt 0 Port 5 Opcode2 OPC, filled by ComboBox Port5 Config lt 112 Port5 Config gt 0 Port 5 Opcode2 ARG1, filled by ComboBox Port5 Config lt 112 Port5 Config gt 0 Port 5 Opcode2 ARG2, filled by ComboBox Port5 Config lt 112 Port5 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 5 Opcode2 OPC and ARG2 Servo position #1 (1-127) Servo position #2 (1-127) Servo speed (1 fast - 7 slow, 4-5 = continuous). Keep same as Port6 speed on 4-pos servo Is this Port used for Occupancy N/Y (set by Type combo) Port 6 DCC Address (decimal, 1-2048) Port 4 DCC Block Occupancy Sensor Address (decimal, 1-4096) Port 6 Config, filled by ComboBox Port 6 Value1 = (Address MINUS 1) & 127 Port 6 Value2A part, filled by ComboBox + address high Port 6 Value2, filled by ComboBox Port6 Config lt 112 Port6 Config gt 0 Port 6 Opcode1 DCC Address (decimal, 1-2048) Port6 Config lt 112 Port6 Config gt 0 Port 6 Opcode1 OPC, filled by ComboBox Port6 Config lt 112 Port6 Config gt 0 Port 6 Opcode1 ARG1, filled by ComboBox Port6 Config lt 112 Port6 Config gt 0 Port 6 Opcode1 Value2, filled by ComboBox Port6 Config lt 112 Port6 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 6 Opcode1 OPC and ARG2 Port6 Config lt 112 Port6 Config gt 0 Port 6 Opcode2 DCC Address (decimal, 1-2048) Port6 Config lt 112 Port6 Config gt 0 Port 6 Opcode2 OPC, filled by ComboBox Port6 Config lt 112 Port6 Config gt 0 Port 6 Opcode2 ARG1, filled by ComboBox Port6 Config lt 112 Port6 Config gt 0 Port 6 Opcode2 ARG2, filled by ComboBox Port6 Config lt 112 Port6 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 6 Opcode2 OPC and ARG2 Servo position #1 (1-127) Servo position #2 (1-127) Servo speed (1 fast - 7 slow, 4-5 = continuous). Keep same as Port5 speed on 4-pos servo Is this Port used for Occupancy N/Y (set by Type combo) Port 7 DCC Address (decimal, 1-2048) Port 7 DCC Block Occupancy Sensor Address (decimal, 1-4096) Port 7 Config, filled by ComboBox Port 7 Value1 = (Address MINUS 1) & 127 Port 7 Value2A part, filled by ComboBox + address high Port 7 Value2, filled by ComboBox Occupied will trigger train control, default: unselected = off Occupied will trigger train reversing, default: unselected = off Port1 Train Slow Down Delay (1-255) Port 1 Train Wait Time (1-255) Port7 Config lt 112 Port7 Config gt 0 Port 7 Opcode1 DCC Address (decimal, 1-2048) Port7 Config lt 112 Port7 Config gt 0 Port 7 Opcode1 OPC, filled by ComboBox Port7 Config lt 112 Port7 Config gt 0 Port 7 Opcode1 ARG1, filled by ComboBox Port7 Config lt 112 Port7 Config gt 0 Port 7 Opcode1 Value2, filled by ComboBox Port7 Config lt 112 Port7 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 7 Opcode1 OPC and ARG2 Port7 Config lt 112 Port7 Config gt 0 Port 7 Opcode2 DCC Address (decimal, 1-2048) Port7 Config lt 112 Port7 Config gt 0 Port 7 Opcode2 OPC, filled by ComboBox Port7 Config lt 112 Port7 Config gt 0 Port 7 Opcode2 ARG1, filled by ComboBox Port7 Config lt 112 Port7 Config gt 0 Port 7 Opcode2 ARG2, filled by ComboBox Port7 Config lt 112 Port7 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 7 Opcode2 OPC and ARG2 Servo position #1 (1-127) Servo position #2 (1-127) Servo speed (1 fast - 7 slow, 4-5 = continuous). Keep same as Port8 speed on 4-pos servo Is this Port used for Occupancy N/Y (set by Type combo) Port 8 DCC Address (decimal, 1-2048) Port 8 DCC Block Occupancy Sensor Address (decimal, 1-4096) Port 8 Config, filled by ComboBox Port 8 Value1 = (Address MINUS 1) & 127 Port 8 Value2A part, filled by ComboBox + address high Port 8 Value2, filled by ComboBox Port8 Config lt 112 Port8 Config gt 0 Port 8 Opcode1 DCC Address (decimal, 1-2048) Port8 Config lt 112 Port8 Config gt 0 Port 8 Opcode1 OPC, filled by ComboBox Port8 Config lt 112 Port8 Config gt 0 Port 8 Opcode1 ARG1, filled by ComboBox Port8 Config lt 112 Port8 Config gt 0 Port 8 Opcode1 Value2, filled by ComboBox Port8 Config lt 112 Port8 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 8 Opcode1 OPC and ARG2 Port8 Config lt 112 Port8 Config gt 0 Port 8 Opcode2 DCC Address (decimal, 1-2048) Port8 Config lt 112 Port8 Config gt 0 Port 8 Opcode2 OPC, filled by ComboBox Port8 Config lt 112 Port8 Config gt 0 Port 8 Opcode2 ARG1, filled by ComboBox Port8 Config lt 112 Port8 Config gt 0 Port 8 Opcode2 ARG2, filled by ComboBox Port8 Config lt 112 Port8 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 8 Opcode2 OPC and ARG2 Servo position #1 (1-127) Servo position #2 (1-127) Servo speed (1 fast - 7 slow, 4-5 = continuous). Keep same as Port7 speed on 4-pos servo Is this Port used for Occupancy N/Y (set by Type combo) Port 9 DCC Address (decimal, 1-2048) Port 9 DCC Block Occupancy Sensor Address (decimal, 1-4096) Port 9 Config, filled by ComboBox Port 9 Value1 = (Address MINUS 1) & 127 Port 9 Value2A part, filled by ComboBox + address high Port 9 Value2, filled by ComboBox Occupied will trigger train control, default: unselected = off Occupied will trigger train reversing, default: unselected = off Port1 Train Slow Down Delay (1-255) Port 1 Train Wait Time (1-255) Port9 Config lt 112 Port9 Config gt 0 Port 9 Opcode1 DCC Address (decimal, 1-2048) Port9 Config lt 112 Port9 Config gt 0 Port 9 Opcode1 OPC, filled by ComboBox Port9 Config lt 112 Port9 Config gt 0 Port 9 Opcode1 ARG1, filled by ComboBox Port9 Config lt 112 Port9 Config gt 0 Port 9 Opcode1 Value2, filled by ComboBox Port9 Config lt 112 Port9 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 9 Opcode1 OPC and ARG2 Port9 Config lt 112 Port9 Config gt 0 Port 9 Opcode2 DCC Address (decimal, 1-2048) Port9 Config lt 112 Port9 Config gt 0 Port 9 Opcode2 OPC, filled by ComboBox Port9 Config lt 112 Port9 Config gt 0 Port 9 Opcode2 ARG1, filled by ComboBox Port9 Config lt 112 Port9 Config gt 0 Port 9 Opcode2 ARG2, filled by ComboBox Port9 Config lt 112 Port9 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 9 Opcode2 OPC and ARG2 Servo position #1 (1-127) Servo position #2 (1-127) Servo speed (1 fast - 7 slow, 4-5 = continuous). Keep same as Port10 speed on 4-pos servo Is this Port used for Occupancy N/Y (set by Type combo) Port 10 DCC Address (decimal, 1-2048) Port 10 DCC Block Occupancy Sensor Address (decimal, 1-4096) Port 10 Config, filled by ComboBox Port 10 Value1 = (Address MINUS 1) & 127 Port 10 Value2A part, filled by ComboBox + address high Port 10 Value2, filled by ComboBox Port10 Config lt 112 Port10 Config gt 0 Port 10 Opcode1 DCC Address (decimal, 1-2048) Port10 Config lt 112 Port10 Config gt 0 Port 10 Opcode1 OPC, filled by ComboBox Port10 Config lt 112 Port10 Config gt 0 Port 10 Opcode1 ARG1, filled by ComboBox Port10 Config lt 112 Port10 Config gt 0 Port 10 Opcode1 Value2, filled by ComboBox Port10 Config lt 112 Port10 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 10 Opcode1 OPC and ARG2 Port10 Config lt 112 Port10 Config gt 0 Port 10 Opcode2 DCC Address (decimal, 1-2048) Port10 Config lt 112 Port10 Config gt 0 Port 10 Opcode2 OPC, filled by ComboBox Port10 Config lt 112 Port10 Config gt 0 Port 10 Opcode2 ARG1, filled by ComboBox Port10 Config lt 112 Port10 Config gt 0 Port 10 Opcode2 ARG2, filled by ComboBox Port10 Config lt 112 Port10 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 10 Opcode2 OPC and ARG2 Servo position #1 (1-127) Servo position #2 (1-127) Servo speed (1 fast - 7 slow, 4-5 = continuous). Keep same as Port9 speed on 4-pos servo Is this Port used for Occupancy N/Y (set by Type combo) Port 11 DCC Address (decimal, 1-2048) Port 11 DCC Block Occupancy Sensor Address (decimal, 1-4096) Port 11 Config, filled by ComboBox Port 11 Value1 = (Address MINUS 1) & 127 Port 11 Value2A part, filled by ComboBox + address high Port 11 Value2, filled by ComboBox Occupied will trigger train control, default: unselected = off Occupied will trigger train reversing, default: unselected = off Port1 Train Slow Down Delay (1-255) Port 1 Train Wait Time (1-255) Port11 Config lt 112 Port11 Config gt 0 Port 11 Opcode1 DCC Address (decimal, 1-2048) Port11 Config lt 112 Port11 Config gt 0 Port 11 Opcode1 OPC, filled by ComboBox Port11 Config lt 112 Port11 Config gt 0 Port 11 Opcode1 ARG1, filled by ComboBox Port11 Config lt 112 Port11 Config gt 0 Port 11 Opcode1 Value2, filled by ComboBox Port11 Config lt 112 Port11 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 11 Opcode1 OPC and ARG2 Port11 Config lt 112 Port11 Config gt 0 Port 11 Opcode2 DCC Address (decimal, 1-2048) Port11 Config lt 112 Port11 Config gt 0 Port 11 Opcode2 OPC, filled by ComboBox Port11 Config lt 112 Port11 Config gt 0 Port 11 Opcode2 ARG1, filled by ComboBox Port11 Config lt 112 Port11 Config gt 0 Port 11 Opcode2 ARG2, filled by ComboBox Port11 Config lt 112 Port11 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 11 Opcode2 OPC and ARG2 Servo position #1 (1-127) Servo position #2 (1-127) Servo speed (1 fast - 7 slow, 4-5 = continuous). Keep same as Port12 speed on 4-pos servo Is this Port used for Occupancy N/Y (set by Type combo) Port 12 DCC Address (decimal, 1-2048) Port 12 DCC Block Occupancy Sensor Address (decimal, 1-4096) Port 12 Config, filled by ComboBox Port 12 Value1 = (Address MINUS 1) & 127 Port 12 Value2A part, filled by ComboBox + address high Port 12 Value2, filled by ComboBox Port12 Config lt 112 Port12 Config gt 0 Port 12 Opcode1 DCC Address (decimal, 1-2048) Port12 Config lt 112 Port12 Config gt 0 Port 12 Opcode1 OPC, filled by ComboBox Port12 Config lt 112 Port12 Config gt 0 Port 12 Opcode1 ARG1, filled by ComboBox Port12 Config lt 112 Port12 Config gt 0 Port 12 Opcode1 Value2, filled by ComboBox Port12 Config lt 112 Port12 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 12 Opcode1 OPC and ARG2 Port12 Config lt 112 Port12 Config gt 0 Port 12 Opcode2 DCC Address (decimal, 1-2048) Port12 Config lt 112 Port12 Config gt 0 Port 12 Opcode2 OPC, filled by ComboBox Port12 Config lt 112 Port12 Config gt 0 Port 12 Opcode2 ARG1, filled by ComboBox Port12 Config lt 112 Port12 Config gt 0 Port 12 Opcode2 ARG2, filled by ComboBox Port12 Config lt 112 Port12 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 12 Opcode2 OPC and ARG2 Servo position #1 (1-127) Servo position #2 (1-127) Servo speed (1 fast - 7 slow, 4-5 = continuous). Keep same as Port11 speed on 4-pos servo Is this Port used for Occupancy N/Y (set by Type combo) Port 13 DCC Address (decimal, 1-2048) Port 13 DCC Block Occupancy Sensor Address (decimal, 1-4096) Port 13 Config, filled by ComboBox Port 13 Value1 = (Address MINUS 1) & 127 Port 13 Value2A part, filled by ComboBox + address high Port 13 Value2, filled by ComboBox Occupied will trigger train control, default: unselected = off Occupied will trigger train reversing, default: unselected = off Port1 Train Slow Down Delay (1-255) Port 1 Train Wait Time (1-255) Port13 Config lt 112 Port13 Config gt 0 Port 13 Opcode1 DCC Address (decimal, 1-2048) Port13 Config lt 112 Port13 Config gt 0 Port 13 Opcode1 OPC, filled by ComboBox Port13 Config lt 112 Port13 Config gt 0 Port 13 Opcode1 ARG1, filled by ComboBox Port13 Config lt 112 Port13 Config gt 0 Port 13 Opcode1 Value2, filled by ComboBox Port13 Config lt 112 Port13 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 13 Opcode1 OPC and ARG2 Port13 Config lt 112 Port13 Config gt 0 Port 13 Opcode2 DCC Address (decimal, 1-2048) Port13 Config lt 112 Port13 Config gt 0 Port 13 Opcode2 OPC, filled by ComboBox Port13 Config lt 112 Port13 Config gt 0 Port 13 Opcode2 ARG1, filled by ComboBox Port13 Config lt 112 Port13 Config gt 0 Port 13 Opcode2 ARG2, filled by ComboBox Port13 Config lt 112 Port13 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 13 Opcode2 OPC and ARG2 Is this Port used for Occupancy N/Y (set by Type combo) Port 14 DCC Address (decimal, 1-2048) Port 14 DCC Block Occupancy Sensor Address (decimal, 1-4096) Port 14 Config, filled by ComboBox Port 14 Value1 = (Address MINUS 1) & 127 Port 14 Value2A part, filled by ComboBox + address high Port 14 Value2, filled by ComboBox Port14 Config lt 112 Port14 Config gt 0 Port 14 Opcode1 DCC Address (decimal, 1-2048) Port14 Config lt 112 Port14 Config gt 0 Port 14 Opcode1 OPC, filled by ComboBox Port14 Config lt 112 Port14 Config gt 0 Port 14 Opcode1 ARG1, filled by ComboBox Port14 Config lt 112 Port14 Config gt 0 Port 14 Opcode1 Value2, filled by ComboBox Port14 Config lt 112 Port14 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 14 Opcode1 OPC and ARG2 Port14 Config lt 112 Port14 Config gt 0 Port 14 Opcode2 DCC Address (decimal, 1-2048) Port14 Config lt 112 Port14 Config gt 0 Port 14 Opcode2 OPC, filled by ComboBox Port14 Config lt 112 Port14 Config gt 0 Port 14 Opcode2 ARG1, filled by ComboBox Port14 Config lt 112 Port14 Config gt 0 Port 14 Opcode2 ARG2, filled by ComboBox Port14 Config lt 112 Port14 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 14 Opcode2 OPC and ARG2 Is this Port used for Occupancy N/Y (set by Type combo) Port 15 DCC Address (decimal, 1-2048) Port 15 DCC Block Occupancy Sensor Address (decimal, 1-4096) Port 15 Config, filled by ComboBox Port 15 Value1 = (Address MINUS 1) & 127 Port 15 Value2A part, filled by ComboBox + address high Port 15 Value2, filled by ComboBox Occupied will trigger train control, default: unselected = off Occupied will trigger train reversing, default: unselected = off Port1 Train Slow Down Delay (1-255) Port 1 Train Wait Time (1-255) Port15 Config lt 112 Port15 Config gt 0 Port 15 Opcode1 DCC Address (decimal, 1-2048) Port15 Config lt 112 Port15 Config gt 0 Port 15 Opcode1 OPC, filled by ComboBox Port15 Config lt 112 Port15 Config gt 0 Port 15 Opcode1 ARG1, filled by ComboBox Port15 Config lt 112 Port15 Config gt 0 Port 15 Opcode1 Value2, filled by ComboBox Port15 Config lt 112 Port15 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 15 Opcode1 OPC and ARG2 Port15 Config lt 112 Port15 Config gt 0 Port 15 Opcode2 DCC Address (decimal, 1-2048) Port15 Config lt 112 Port15 Config gt 0 Port 15 Opcode2 OPC, filled by ComboBox Port15 Config lt 112 Port15 Config gt 0 Port 15 Opcode2 ARG1, filled by ComboBox Port15 Config lt 112 Port15 Config gt 0 Port 15 Opcode2 ARG2, filled by ComboBox Port15 Config lt 112 Port15 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 15 Opcode2 OPC and ARG2 Is this Port used for Occupancy N/Y (set by Type combo) Port 16 DCC Address (decimal, 1-2048) Port 16 DCC Block Occupancy Sensor Address (decimal, 1-4096) Port 16 Config, filled by ComboBox Port 16 Value1 = (Address MINUS 1) & 127 Port 16 Value2A part, filled by ComboBox + address high Port 16 Value2, filled by ComboBox Port16 Config lt 112 Port16 Config gt 0 Port 16 Opcode1 DCC Address (decimal, 1-2048) Port16 Config lt 112 Port16 Config gt 0 Port 16 Opcode1 OPC, filled by ComboBox Port16 Config lt 112 Port16 Config gt 0 Port 16 Opcode1 ARG1, filled by ComboBox Port16 Config lt 112 Port16 Config gt 0 Port 16 Opcode1 Value2, filled by ComboBox Port16 Config lt 112 Port16 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 16 Opcode1 OPC and ARG2 Port16 Config lt 112 Port16 Config gt 0 Port 16 Opcode2 DCC Address (decimal, 1-2048) Port16 Config lt 112 Port16 Config gt 0 Port 16 Opcode2 OPC, filled by ComboBox Port16 Config lt 112 Port16 Config gt 0 Port 16 Opcode2 ARG1, filled by ComboBox Port16 Config lt 112 Port16 Config gt 0 Port 16 Opcode2 ARG2, filled by ComboBox Port16 Config lt 112 Port16 Config gt 0 Off Inaktiv Uit Contact1 Direct Contact1 Indirect Contact2 Direct Contact2 Indirect Port 16 Opcode2 OPC and ARG2 Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Toggle switch Ingang: Wisselschakelaar Input: Toggle switch - Indirect Ingang: Wisselcontact - Indirect Input: Block Detector (odd address) Input: Block Detector (even address) Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Input: Block Detector - active High (odd address) Input: Block Detector - active High (even address) Input: Block Detector - active High Delayed (odd) Input: Block Detector - active High Delayed (even) Input: Push button - active High (odd address) Input: Push button - active High (even address) Input: Push button - active High - Indirect (odd) Input: Push button - active High - Indirect (even) Input: Push button - active Low (odd address) Input: Push button - active Low (even address) Input: Push button - active Low - Indirect (odd) Input: Push button - active Low - Indirect (even) Input: Feedback - Normal Input: Feedback - Contact 1 Input: Feedback - Contact 2 Output: Pulse 1 Output: Pulse 2 Output: Pulse 1 - Soft Reset Output: Pulse 2 - Soft Reset Output: Pulse 1 - Hard Reset Output: Pulse 2 - Hard Reset Output: Fixed 1 - On Output: Fixed 1 - Off Output: Fixed 1 - On - Blinking Output: Fixed 1 - Off - Blinking Output: Fixed 1 - On - 4-Way Output: Fixed 1 - Off - 4-Way Output: Fixed 1 - On - 4-Way - Blinking Output: Fixed 1 - Off - 4-Way - Blinking Output: Fixed 2 - On Output: Fixed 2 - Off Output: Fixed 2 - On - Blinking Output: Fixed 2 - Off - Blinking Output: Fixed 2 - On - 4-Way Output: Fixed 2 - Off - 4-Way Output: Fixed 2 - On - 4-Way - Blinking Output: Fixed 2 - Off - 4-Way - Blinking Output: Block Detector (odd address) Uitgang: Bezetmelder (oneven) Output: Block Detector (even address) Uitgang: Bezetmelder (even) Output: Block Detector - Blinking (odd) Uitgang: Bezetmelder - knipperend (even) Output: Block Detector - Blinking (even) Uitgang: Bezetmelder - knipperend (even) Output: LocoView (odd address) Uitgang: LocoView (oneven adres) Output: LocoView (even address) Uitgang: LocoView (even adres) Select Port 1 operation mode. Sets Config and Value2 Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Port 1 Config and Value2 for RCD connection.
Select only one active port on this LocoRCD board
Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Toggle switch Ingang: Wisselschakelaar Input: Toggle switch - Indirect Ingang: Wisselcontact - Indirect Input: Block Detector (odd address) Input: Block Detector (even address) Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Input: Block Detector - active High (odd address) Input: Block Detector - active High (even address) Input: Block Detector - active High Delayed (odd) Input: Block Detector - active High Delayed (even) Input: Push button - active High (odd address) Input: Push button - active High (even address) Input: Push button - active High - Indirect (odd) Input: Push button - active High - Indirect (even) Input: Push button - active Low (odd address) Input: Push button - active Low (even address) Input: Push button - active Low - Indirect (odd) Input: Push button - active Low - Indirect (even) Input: Feedback - Normal Input: Feedback - Contact 1 Input: Feedback - Contact 2 Output: Pulse 1 Output: Pulse 2 Output: Pulse 1 - Soft Reset Output: Pulse 2 - Soft Reset Output: Pulse 1 - Hard Reset Output: Pulse 2 - Hard Reset Output: Fixed 1 - On Output: Fixed 1 - Off Output: Fixed 1 - On - Blinking Output: Fixed 1 - Off - Blinking Output: Fixed 1 - On - 4-Way Output: Fixed 1 - Off - 4-Way Output: Fixed 1 - On - 4-Way - Blinking Output: Fixed 1 - Off - 4-Way - Blinking Output: Fixed 2 - On Output: Fixed 2 - Off Output: Fixed 2 - On - Blinking Output: Fixed 2 - Off - Blinking Output: Fixed 2 - On - 4-Way Output: Fixed 2 - Off - 4-Way Output: Fixed 2 - On - 4-Way - Blinking Output: Fixed 2 - Off - 4-Way - Blinking Output: Block Detector (odd address) Uitgang: Bezetmelder (oneven) Output: Block Detector (even address) Uitgang: Bezetmelder (even) Output: Block Detector - Blinking (odd) Uitgang: Bezetmelder - knipperend (oneven) Output: Block Detector - Blinking (even) Uitgang: Bezetmelder - knipperend (even) Select Port 2 operation mode. Sets Config and Value2 Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Port 2 Config and Value2 for RCD connection.
Select only one active port on this LocoRCD board
Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Toggle switch Ingang: Wisselschakelaar Input: Toggle switch - Indirect Ingang: Wisselcontact - Indirect Input: Block Detector (odd address) Input: Block Detector (even address) Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Input: Block Detector - active High (odd address) Input: Block Detector - active High (even address) Input: Block Detector - active High Delayed (odd) Input: Block Detector - active High Delayed (even) Input: Push button - active High (odd address) Input: Push button - active High (even address) Input: Push button - active High - Indirect (odd) Input: Push button - active High - Indirect (even) Input: Push button - active Low (odd address) Input: Push button - active Low (even address) Input: Push button - active Low - Indirect (odd) Input: Push button - active Low - Indirect (even) Input: Feedback - Normal Input: Feedback - Contact 1 Input: Feedback - Contact 2 Output: Pulse 1 Output: Pulse 2 Output: Pulse 1 - Soft Reset Output: Pulse 2 - Soft Reset Output: Pulse 1 - Hard Reset Output: Pulse 2 - Hard Reset Output: Fixed 1 - On Output: Fixed 1 - Off Output: Fixed 1 - On - Blinking Output: Fixed 1 - Off - Blinking Output: Fixed 1 - On - 4-Way Output: Fixed 1 - Off - 4-Way Output: Fixed 1 - On - 4-Way - Blinking Output: Fixed 1 - Off - 4-Way - Blinking Output: Fixed 2 - On Output: Fixed 2 - Off Output: Fixed 2 - On - Blinking Output: Fixed 2 - Off - Blinking Output: Fixed 2 - On - 4-Way Output: Fixed 2 - Off - 4-Way Output: Fixed 2 - On - 4-Way - Blinking Output: Fixed 2 - Off - 4-Way - Blinking Output: Block Detector (odd address) Uitgang: Bezetmelder (oneven) Output: Block Detector (even address) Uitgang: Bezetmelder (even) Output: Block Detector - Blinking (odd) Uitgang: Bezetmelder - knipperend (even) Output: Block Detector - Blinking (even) Uitgang: Bezetmelder - knipperend (even) Select Port 3 operation mode. Sets Config and Value2 Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Port 3 Config and Value2 for RCD connection.
Select only one active port on this LocoRCD board
Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Toggle switch Ingang: Wisselschakelaar Input: Toggle switch - Indirect Ingang: Wisselcontact - Indirect Input: Block Detector (odd address) Input: Block Detector (even address) Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Input: Block Detector - active High (odd address) Input: Block Detector - active High (even address) Input: Block Detector - active High Delayed (odd) Input: Block Detector - active High Delayed (even) Input: Push button - active High (odd address) Input: Push button - active High (even address) Input: Push button - active High - Indirect (odd) Input: Push button - active High - Indirect (even) Input: Push button - active Low (odd address) Input: Push button - active Low (even address) Input: Push button - active Low - Indirect (odd) Input: Push button - active Low - Indirect (even) Input: Feedback - Normal Input: Feedback - Contact 1 Input: Feedback - Contact 2 Output: Pulse 1 Output: Pulse 2 Output: Pulse 1 - Soft Reset Output: Pulse 2 - Soft Reset Output: Pulse 1 - Hard Reset Output: Pulse 2 - Hard Reset Output: Fixed 1 - On Output: Fixed 1 - Off Output: Fixed 1 - On - Blinking Output: Fixed 1 - Off - Blinking Output: Fixed 1 - On - 4-Way Output: Fixed 1 - Off - 4-Way Output: Fixed 1 - On - 4-Way - Blinking Output: Fixed 1 - Off - 4-Way - Blinking Output: Fixed 2 - On Output: Fixed 2 - Off Output: Fixed 2 - On - Blinking Output: Fixed 2 - Off - Blinking Output: Fixed 2 - On - 4-Way Output: Fixed 2 - Off - 4-Way Output: Fixed 2 - On - 4-Way - Blinking Output: Fixed 2 - Off - 4-Way - Blinking Output: Block Detector (odd address) Uitgang: Bezetmelder (oneven) Output: Block Detector (even address) Uitgang: Bezetmelder (even) Output: Block Detector - Blinking (odd) Uitgang: Bezetmelder - knipperend (even) Output: Block Detector - Blinking (even) Uitgang: Bezetmelder - knipperend (even) Select Port 4 operation mode. Sets Config and Value2 Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Port 4 Config and Value2 for RCD connection.
Select only one active port on this LocoRCD board
Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Toggle switch Ingang: Wisselschakelaar Input: Toggle switch - Indirect Ingang: Wisselcontact - Indirect Input: Block Detector (odd address) Input: Block Detector (even address) Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Input: Block Detector - active High (odd address) Input: Block Detector - active High (even address) Input: Block Detector - active High Delayed (odd) Input: Block Detector - active High Delayed (even) Input: Push button - active High (odd address) Input: Push button - active High (even address) Input: Push button - active High - Indirect (odd) Input: Push button - active High - Indirect (even) Input: Push button - active Low (odd address) Input: Push button - active Low (even address) Input: Push button - active Low - Indirect (odd) Input: Push button - active Low - Indirect (even) Input: Feedback - Normal Input: Feedback - Contact 1 Input: Feedback - Contact 2 Output: Pulse 1 Output: Pulse 2 Output: Pulse 1 - Soft Reset Output: Pulse 2 - Soft Reset Output: Pulse 1 - Hard Reset Output: Pulse 2 - Hard Reset Output: Fixed 1 - On Output: Fixed 1 - Off Output: Fixed 1 - On - Blinking Output: Fixed 1 - Off - Blinking Output: Fixed 1 - On - 4-Way Output: Fixed 1 - Off - 4-Way Output: Fixed 1 - On - 4-Way - Blinking Output: Fixed 1 - Off - 4-Way - Blinking Output: Fixed 2 - On Output: Fixed 2 - Off Output: Fixed 2 - On - Blinking Output: Fixed 2 - Off - Blinking Output: Fixed 2 - On - 4-Way Output: Fixed 2 - Off - 4-Way Output: Fixed 2 - On - 4-Way - Blinking Output: Fixed 2 - Off - 4-Way - Blinking Output: Block Detector (odd address) Uitgang: Bezetmelder (oneven) Output: Block Detector (even address) Uitgang: Bezetmelder (even) Output: Block Detector - Blinking (odd) Uitgang: Bezetmelder - knipperend (even) Output: Block Detector - Blinking (even) Uitgang: Bezetmelder - knipperend (even) Output: LocoView (odd address) Uitgang: LocoView (oneven adres) Output: LocoView (even address) Uitgang: LocoView (even adres) Select Port 5 operation mode. Sets Config and Value2 Input: Feedback of Booster In Ingang: Feedback van Booster In Select... Auswählen... Selecteer... LocoBooster - Booster Power Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Port 5 Config and Value2 for RCD connection.
Select only one active port on this LocoRCD board
Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Toggle switch Ingang: Wisselschakelaar Input: Toggle switch - Indirect Ingang: Wisselcontact - Indirect Input: Block Detector (odd address) Input: Block Detector (even address) Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Input: Block Detector - active High (odd address) Input: Block Detector - active High (even address) Input: Block Detector - active High Delayed (odd) Input: Block Detector - active High Delayed (even) Input: Push button - active High (odd address) Input: Push button - active High (even address) Input: Push button - active High - Indirect (odd) Input: Push button - active High - Indirect (even) Input: Push button - active Low (odd address) Input: Push button - active Low (even address) Input: Push button - active Low - Indirect (odd) Input: Push button - active Low - Indirect (even) Input: Feedback - Normal Input: Feedback - Contact 1 Input: Feedback - Contact 2 Output: Pulse 1 Output: Pulse 2 Output: Pulse 1 - Soft Reset Output: Pulse 2 - Soft Reset Output: Pulse 1 - Hard Reset Output: Pulse 2 - Hard Reset Output: Fixed 1 - On Output: Fixed 1 - Off Output: Fixed 1 - On - Blinking Output: Fixed 1 - Off - Blinking Output: Fixed 1 - On - 4-Way Output: Fixed 1 - Off - 4-Way Output: Fixed 1 - On - 4-Way - Blinking Output: Fixed 1 - Off - 4-Way - Blinking Output: Fixed 2 - On Output: Fixed 2 - Off Output: Fixed 2 - On - Blinking Output: Fixed 2 - Off - Blinking Output: Fixed 2 - On - 4-Way Output: Fixed 2 - Off - 4-Way Output: Fixed 2 - On - 4-Way - Blinking Output: Fixed 2 - Off - 4-Way - Blinking Output: Block Detector (odd address) Uitgang: Bezetmelder (oneven) Output: Block Detector (even address) Uitgang: Bezetmelder (even) Output: Block Detector - Blinking (odd) Uitgang: Bezetmelder - knipperend (even) Output: Block Detector - Blinking (even) Uitgang: Bezetmelder - knipperend (even) Select Port 6 operation mode. Sets Config and Value2 Input: Feedback of Booster Out Ingang: Feedback van Booster Uit Select... Auswählen... Selecteer... LocoBooster - Booster Power Output: Servo 2 (2/4 pos on tab Loco...) Uitgang: Servo (2/4 pos. op tab LocoIO) Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Port 6 Config and Value2 for servo connection Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Port 6 Config and Value2 for RCD connection.
Select only one active port on this LocoRCD board
Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Toggle switch Ingang: Wisselschakelaar Input: Toggle switch - Indirect Ingang: Wisselcontact - Indirect Input: Block Detector (odd address) Input: Block Detector (even address) Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Input: Block Detector - active High (odd address) Input: Block Detector - active High (even address) Input: Block Detector - active High Delayed (odd) Input: Block Detector - active High Delayed (even) Input: Push button - active High (odd address) Input: Push button - active High (even address) Input: Push button - active High - Indirect (odd) Input: Push button - active High - Indirect (even) Input: Push button - active Low (odd address) Input: Push button - active Low (even address) Input: Push button - active Low - Indirect (odd) Input: Push button - active Low - Indirect (even) Input: Feedback - Normal Input: Feedback - Contact 1 Input: Feedback - Contact 2 Output: Pulse 1 Output: Pulse 2 Output: Pulse 1 - Soft Reset Output: Pulse 2 - Soft Reset Output: Pulse 1 - Hard Reset Output: Pulse 2 - Hard Reset Output: Fixed 1 - On Output: Fixed 1 - Off Output: Fixed 1 - On - Blinking Output: Fixed 1 - Off - Blinking Output: Fixed 1 - On - 4-Way Output: Fixed 1 - Off - 4-Way Output: Fixed 1 - On - 4-Way - Blinking Output: Fixed 1 - Off - 4-Way - Blinking Output: Fixed 2 - On Output: Fixed 2 - Off Output: Fixed 2 - On - Blinking Output: Fixed 2 - Off - Blinking Output: Fixed 2 - On - 4-Way Output: Fixed 2 - Off - 4-Way Output: Fixed 2 - On - 4-Way - Blinking Output: Fixed 2 - Off - 4-Way - Blinking Output: Block Detector (odd address) Uitgang: Bezetmelder (oneven) Output: Block Detector (even address) Uitgang: Bezetmelder (even) Output: Block Detector - Blinking (odd) Uitgang: Bezetmelder - knipperend (even) Output: Block Detector - Blinking (even) Uitgang: Bezetmelder - knipperend (even) Select Port 7 operation mode. Sets Config and Value2 Output: Fixed 1 - On Output: Fixed 1 - Off LocoBooster - Booster Status Output: Servo 3 (2/4 pos on tab Loco...) Uitgang: Servo (2/4 pos. op tab LocoIO) Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Port 7 Config and Value2 for servo connection Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Port 7 Config and Value2 for RCD connection.
Select only one active port on this LocoRCD board
Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Toggle switch Ingang: Wisselschakelaar Input: Toggle switch - Indirect Ingang: Wisselcontact - Indirect Input: Block Detector (odd address) Input: Block Detector (even address) Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Input: Block Detector - active High (odd address) Input: Block Detector - active High (even address) Input: Block Detector - active High Delayed (odd) Input: Block Detector - active High Delayed (even) Input: Push button - active High (odd address) Input: Push button - active High (even address) Input: Push button - active High - Indirect (odd) Input: Push button - active High - Indirect (even) Input: Push button - active Low (odd address) Input: Push button - active Low (even address) Input: Push button - active Low - Indirect (odd) Input: Push button - active Low - Indirect (even) Input: Feedback - Normal Input: Feedback - Contact 1 Input: Feedback - Contact 2 Output: Pulse 1 Output: Pulse 2 Output: Pulse 1 - Soft Reset Output: Pulse 2 - Soft Reset Output: Pulse 1 - Hard Reset Output: Pulse 2 - Hard Reset Output: Fixed 1 - On Output: Fixed 1 - Off Output: Fixed 1 - On - Blinking Output: Fixed 1 - Off - Blinking Output: Fixed 1 - On - 4-Way Output: Fixed 1 - Off - 4-Way Output: Fixed 1 - On - 4-Way - Blinking Output: Fixed 1 - Off - 4-Way - Blinking Output: Fixed 2 - On Output: Fixed 2 - Off Output: Fixed 2 - On - Blinking Output: Fixed 2 - Off - Blinking Output: Fixed 2 - On - 4-Way Output: Fixed 2 - Off - 4-Way Output: Fixed 2 - On - 4-Way - Blinking Output: Fixed 2 - Off - 4-Way - Blinking Output: Block Detector (odd address) Uitgang: Bezetmelder (oneven) Output: Block Detector (even address) Uitgang: Bezetmelder (even) Output: Block Detector - Blinking (odd) Uitgang: Bezetmelder - knipperend (even) Output: Block Detector - Blinking (even) Uitgang: Bezetmelder - knipperend (even) Select Port 8 operation mode. Sets Config and Value2 Output: Servo 4 (2/4 pos on tab Loco...) Uitgang: Servo (2/4 pos. op tab LocoIO) Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Port 8 Config and Value2 for servo connection Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Port 8 Config and Value2 for RCD connection.
Select only one active port on this LocoRCD board
Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Toggle switch Ingang: Wisselschakelaar Input: Toggle switch - Indirect Ingang: Wisselcontact - Indirect Input: Block Detector (odd address) Input: Block Detector (even address) Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Input: Block Detector - active High (odd address) Input: Block Detector - active High (even address) Input: Block Detector - active High Delayed (odd) Input: Block Detector - active High Delayed (even) Input: Push button - active High (odd address) Input: Push button - active High (even address) Input: Push button - active High - Indirect (odd) Input: Push button - active High - Indirect (even) Input: Push button - active Low (odd address) Input: Push button - active Low (even address) Input: Push button - active Low - Indirect (odd) Input: Push button - active Low - Indirect (even) Input: Feedback - Normal Input: Feedback - Contact 1 Input: Feedback - Contact 2 Output: Pulse 1 Output: Pulse 2 Output: Pulse 1 - Soft Reset Output: Pulse 2 - Soft Reset Output: Pulse 1 - Hard Reset Output: Pulse 2 - Hard Reset Output: Fixed 1 - On Output: Fixed 1 - Off Output: Fixed 1 - On - Blinking Output: Fixed 1 - Off - Blinking Output: Fixed 1 - On - 4-Way Output: Fixed 1 - Off - 4-Way Output: Fixed 1 - On - 4-Way - Blinking Output: Fixed 1 - Off - 4-Way - Blinking Output: Fixed 2 - On Output: Fixed 2 - Off Output: Fixed 2 - On - Blinking Output: Fixed 2 - Off - Blinking Output: Fixed 2 - On - 4-Way Output: Fixed 2 - Off - 4-Way Output: Fixed 2 - On - 4-Way - Blinking Output: Fixed 2 - Off - 4-Way - Blinking Output: Block Detector (odd address) Uitgang: Bezetmelder (oneven) Output: Block Detector (even address) Uitgang: Bezetmelder (even) Output: Block Detector - Blinking (odd) Uitgang: Bezetmelder - knipperend (even) Output: Block Detector - Blinking (even) Uitgang: Bezetmelder - knipperend (even) Output: LocoView (odd address) Uitgang: LocoView (oneven adres) Output: LocoView (even address) Uitgang: LocoView (even adres) Select Port 9 operation mode. Sets Config and Value2 Output: Servo 5 (2/4 pos on tab Loco...) Uitgang: Servo (2/4 pos. op tab LocoIO) Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Port 9 Config and Value2 for servo connection Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Port 9 Config and Value2 for RCD connection.
Select only one active port on this LocoRCD board
Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Toggle switch Ingang: Wisselschakelaar Input: Toggle switch - Indirect Ingang: Wisselcontact - Indirect Input: Block Detector (odd address) Input: Block Detector (even address) Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Input: Block Detector - active High (odd address) Input: Block Detector - active High (even address) Input: Block Detector - active High Delayed (odd) Input: Block Detector - active High Delayed (even) Input: Push button - active High (odd address) Input: Push button - active High (even address) Input: Push button - active High - Indirect (odd) Input: Push button - active High - Indirect (even) Input: Push button - active Low (odd address) Input: Push button - active Low (even address) Input: Push button - active Low - Indirect (odd) Input: Push button - active Low - Indirect (even) Input: Feedback - Normal Input: Feedback - Contact 1 Input: Feedback - Contact 2 Output: Pulse 1 Output: Pulse 2 Output: Pulse 1 - Soft Reset Output: Pulse 2 - Soft Reset Output: Pulse 1 - Hard Reset Output: Pulse 2 - Hard Reset Output: Fixed 1 - On Output: Fixed 1 - Off Output: Fixed 1 - On - Blinking Output: Fixed 1 - Off - Blinking Output: Fixed 1 - On - 4-Way Output: Fixed 1 - Off - 4-Way Output: Fixed 1 - On - 4-Way - Blinking Output: Fixed 1 - Off - 4-Way - Blinking Output: Fixed 2 - On Output: Fixed 2 - Off Output: Fixed 2 - On - Blinking Output: Fixed 2 - Off - Blinking Output: Fixed 2 - On - 4-Way Output: Fixed 2 - Off - 4-Way Output: Fixed 2 - On - 4-Way - Blinking Output: Fixed 2 - Off - 4-Way - Blinking Output: Block Detector (odd address) Uitgang: Bezetmelder (oneven) Output: Block Detector (even address) Uitgang: Bezetmelder (even) Output: Block Detector - Blinking (odd) Uitgang: Bezetmelder - knipperend (even) Output: Block Detector - Blinking (even) Uitgang: Bezetmelder - knipperend (even) Select Port 10 operation mode. Sets Config and Value2 Output: Servo 6 (2/4 pos on tab Loco...) Uitgang: Servo (2/4 pos. op tab LocoIO) Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Port 10 Config and Value2 for servo connection Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Port 10 Config and Value2 for RCD connection.
Select only one active port on this LocoRCD board
Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Toggle switch Ingang: Wisselschakelaar Input: Toggle switch - Indirect Ingang: Wisselcontact - Indirect Input: Block Detector (odd address) Input: Block Detector (even address) Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Input: Block Detector - active High (odd address) Input: Block Detector - active High (even address) Input: Block Detector - active High Delayed (odd) Input: Block Detector - active High Delayed (even) Input: Push button - active High (odd address) Input: Push button - active High (even address) Input: Push button - active High - Indirect (odd) Input: Push button - active High - Indirect (even) Input: Push button - active Low (odd address) Input: Push button - active Low (even address) Input: Push button - active Low - Indirect (odd) Input: Push button - active Low - Indirect (even) Input: Feedback - Normal Input: Feedback - Contact 1 Input: Feedback - Contact 2 Output: Pulse 1 Output: Pulse 2 Output: Pulse 1 - Soft Reset Output: Pulse 2 - Soft Reset Output: Pulse 1 - Hard Reset Output: Pulse 2 - Hard Reset Output: Fixed 1 - On Output: Fixed 1 - Off Output: Fixed 1 - On - Blinking Output: Fixed 1 - Off - Blinking Output: Fixed 1 - On - 4-Way Output: Fixed 1 - Off - 4-Way Output: Fixed 1 - On - 4-Way - Blinking Output: Fixed 1 - Off - 4-Way - Blinking Output: Fixed 2 - On Output: Fixed 2 - Off Output: Fixed 2 - On - Blinking Output: Fixed 2 - Off - Blinking Output: Fixed 2 - On - 4-Way Output: Fixed 2 - Off - 4-Way Output: Fixed 2 - On - 4-Way - Blinking Output: Fixed 2 - Off - 4-Way - Blinking Output: Block Detector (odd address) Uitgang: Bezetmelder (oneven) Output: Block Detector (even address) Uitgang: Bezetmelder (even) Output: Block Detector - Blinking (odd) Uitgang: Bezetmelder - knipperend (even) Output: Block Detector - Blinking (even) Uitgang: Bezetmelder - knipperend (even) Select Port 11 operation mode. Sets Config and Value2 Output: Servo 5 (2/4 pos on tab Loco...) Uitgang: Servo (2/4 pos. op tab LocoIO) Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Port 11 Config and Value2 for servo connection Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Port 11 Config and Value2 for RCD connection.
Select only one active port on this LocoRCD board
Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Toggle switch Ingang: Wisselschakelaar Input: Toggle switch - Indirect Ingang: Wisselcontact - Indirect Input: Block Detector (odd address) Input: Block Detector (even address) Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Input: Block Detector - active High (odd address) Input: Block Detector - active High (even address) Input: Block Detector - active High Delayed (odd) Input: Block Detector - active High Delayed (even) Input: Push button - active High (odd address) Input: Push button - active High (even address) Input: Push button - active High - Indirect (odd) Input: Push button - active High - Indirect (even) Input: Push button - active Low (odd address) Input: Push button - active Low (even address) Input: Push button - active Low - Indirect (odd) Input: Push button - active Low - Indirect (even) Input: Feedback - Normal Input: Feedback - Contact 1 Input: Feedback - Contact 2 Output: Pulse 1 Output: Pulse 2 Output: Pulse 1 - Soft Reset Output: Pulse 2 - Soft Reset Output: Pulse 1 - Hard Reset Output: Pulse 2 - Hard Reset Output: Fixed 1 - On Output: Fixed 1 - Off Output: Fixed 1 - On - Blinking Output: Fixed 1 - Off - Blinking Output: Fixed 1 - On - 4-Way Output: Fixed 1 - Off - 4-Way Output: Fixed 1 - On - 4-Way - Blinking Output: Fixed 1 - Off - 4-Way - Blinking Output: Fixed 2 - On Output: Fixed 2 - Off Output: Fixed 2 - On - Blinking Output: Fixed 2 - Off - Blinking Output: Fixed 2 - On - 4-Way Output: Fixed 2 - Off - 4-Way Output: Fixed 2 - On - 4-Way - Blinking Output: Fixed 2 - Off - 4-Way - Blinking Output: Block Detector (odd address) Uitgang: Bezetmelder (oneven) Output: Block Detector (even address) Uitgang: Bezetmelder (even) Output: Block Detector - Blinking (odd) Uitgang: Bezetmelder - knipperend (even) Output: Block Detector - Blinking (even) Uitgang: Bezetmelder - knipperend (even) Select Port 12 operation mode. Sets Config and Value2 Output: Servo 6 (2/4 pos on tab Loco...) Uitgang: Servo (2/4 pos. op tab LocoIO) Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Port 12 Config and Value2 for servo connection Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Port 12 Config and Value2 for RCD connection.
Select only one active port on this LocoRCD board
Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Toggle switch Ingang: Wisselschakelaar Input: Toggle switch - Indirect Ingang: Wisselcontact - Indirect Input: Block Detector (odd address) Input: Block Detector (even address) Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Input: Block Detector - active High (odd address) Input: Block Detector - active High (even address) Input: Block Detector - active High Delayed (odd) Input: Block Detector - active High Delayed (even) Input: Push button - active High (odd address) Input: Push button - active High (even address) Input: Push button - active High - Indirect (odd) Input: Push button - active High - Indirect (even) Input: Push button - active Low (odd address) Input: Push button - active Low (even address) Input: Push button - active Low - Indirect (odd) Input: Push button - active Low - Indirect (even) Input: Feedback - Normal Input: Feedback - Contact 1 Input: Feedback - Contact 2 Output: Pulse 1 Output: Pulse 2 Output: Pulse 1 - Soft Reset Output: Pulse 2 - Soft Reset Output: Pulse 1 - Hard Reset Output: Pulse 2 - Hard Reset Output: Fixed 1 - On Output: Fixed 1 - Off Output: Fixed 1 - On - Blinking Output: Fixed 1 - Off - Blinking Output: Fixed 1 - On - 4-Way Output: Fixed 1 - Off - 4-Way Output: Fixed 1 - On - 4-Way - Blinking Output: Fixed 1 - Off - 4-Way - Blinking Output: Fixed 2 - On Output: Fixed 2 - Off Output: Fixed 2 - On - Blinking Output: Fixed 2 - Off - Blinking Output: Fixed 2 - On - 4-Way Output: Fixed 2 - Off - 4-Way Output: Fixed 2 - On - 4-Way - Blinking Output: Fixed 2 - Off - 4-Way - Blinking Output: Block Detector (odd address) Uitgang: Bezetmelder (oneven) Output: Block Detector (even address) Uitgang: Bezetmelder (even) Output: Block Detector - Blinking (odd) Uitgang: Bezetmelder - knipperend (even) Output: Block Detector - Blinking (even) Uitgang: Bezetmelder - knipperend (even) Output: LocoView (odd address) Uitgang: LocoView (oneven adres) Output: LocoView (even address) Uitgang: LocoView (even adres) Select Port 13 operation mode. Sets Config and Value2 Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Port 13 Config and Value2 for RCD connection.
Select only one active port on this LocoRCD board
Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Toggle switch Ingang: Wisselschakelaar Input: Toggle switch - Indirect Ingang: Wisselcontact - Indirect Input: Block Detector (odd address) Input: Block Detector (even address) Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed )dd) Input: Block Detector - active Low Delayed (even) Input: Block Detector - active High (odd address) Input: Block Detector - active High (even address) Input: Block Detector - active High Delayed (odd) Input: Block Detector - active High Delayed (even) Input: Push button - active High (odd address) Input: Push button - active High (even address) Input: Push button - active High - Indirect (odd) Input: Push button - active High - Indirect (even) Input: Push button - active Low (odd address) Input: Push button - active Low (even address) Input: Push button - active Low - Indirect (odd) Input: Push button - active Low - Indirect (even) Input: Feedback - Normal Input: Feedback - Contact 1 Input: Feedback - Contact 2 Output: Pulse 1 Output: Pulse 2 Output: Pulse 1 - Soft Reset Output: Pulse 2 - Soft Reset Output: Pulse 1 - Hard Reset Output: Pulse 2 - Hard Reset Output: Fixed 1 - On Output: Fixed 1 - Off Output: Fixed 1 - On - Blinking Output: Fixed 1 - Off - Blinking Output: Fixed 1 - On - 4-Way Output: Fixed 1 - Off - 4-Way Output: Fixed 1 - On - 4-Way - Blinking Output: Fixed 1 - Off - 4-Way - Blinking Output: Fixed 2 - On Output: Fixed 2 - Off Output: Fixed 2 - On - Blinking Output: Fixed 2 - Off - Blinking Output: Fixed 2 - On - 4-Way Output: Fixed 2 - Off - 4-Way Output: Fixed 2 - On - 4-Way - Blinking Output: Fixed 2 - Off - 4-Way - Blinking Output: Block Detector (odd address) Uitgang: Bezetmelder (oneven) Output: Block Detector (even address) Uitgang: Bezetmelder (even) Output: Block Detector - Blinking (odd) Uitgang: Bezetmelder - knipperend (even) Output: Block Detector - Blinking (even) Uitgang: Bezetmelder - knipperend (even) Select Port 14 operation mode. Sets Config and Value2 Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Port 14 Config and Value2 for RCD connection.
Select only one active port on this LocoRCD board
Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Toggle switch Ingang: Wisselschakelaar Input: Toggle switch - Indirect Ingang: Wisselcontact - Indirect Input: Block Detector (odd address) Input: Block Detector (even address) Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Input: Block Detector - active High (odd address) Input: Block Detector - active High (even address) Input: Block Detector - active High Delayed (odd) Input: Block Detector - active High Delayed (even) Input: Push button - active High (odd address) Input: Push button - active High (even address) Input: Push button - active High - Indirect (odd) Input: Push button - active High - Indirect (even) Input: Push button - active Low (odd address) Input: Push button - active Low (even address) Input: Push button - active Low - Indirect (odd) Input: Push button - active Low - Indirect (even) Input: Feedback - Normal Input: Feedback - Contact 1 Input: Feedback - Contact 2 Output: Pulse 1 Output: Pulse 2 Output: Pulse 1 - Soft Reset Output: Pulse 2 - Soft Reset Output: Pulse 1 - Hard Reset Output: Pulse 2 - Hard Reset Output: Fixed 1 - On Output: Fixed 1 - Off Output: Fixed 1 - On - Blinking Output: Fixed 1 - Off - Blinking Output: Fixed 1 - On - 4-Way Output: Fixed 1 - Off - 4-Way Output: Fixed 1 - On - 4-Way - Blinking Output: Fixed 1 - Off - 4-Way - Blinking Output: Fixed 2 - On Output: Fixed 2 - Off Output: Fixed 2 - On - Blinking Output: Fixed 2 - Off - Blinking Output: Fixed 2 - On - 4-Way Output: Fixed 2 - Off - 4-Way Output: Fixed 2 - On - 4-Way - Blinking Output: Fixed 2 - Off - 4-Way - Blinking Output: Block Detector (odd address) Uitgang: Bezetmelder (oneven) Output: Block Detector (even address) Uitgang: Bezetmelder (even) Output: Block Detector - Blinking (odd) Uitgang: Bezetmelder - knipperend (even) Output: Block Detector - Blinking (even) Uitgang: Bezetmelder - knipperend (even) Select Port 15 operation mode. Sets Config and Value2 Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Port 15 Config and Value2 for RCD connection.
Select only one active port on this LocoRCD board
Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Toggle switch Ingang: Wisselschakelaar Input: Toggle switch - Indirect Ingang: Wisselcontact - Indirect Input: Block Detector (odd address) Input: Block Detector (even address) Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Input: Block Detector - active High (odd address) Input: Block Detector - active High (even address) Input: Block Detector - active High Delayed (odd) Input: Block Detector - active High Delayed (even) Input: Push button - active High (odd address) Input: Push button - active High (even address) Input: Push button - active High - Indirect (odd) Input: Push button - active High - Indirect (even) Input: Push button - active Low (odd address) Input: Push button - active Low (even address) Input: Push button - active Low - Indirect (odd) Input: Push button - active Low - Indirect (even) Input: Feedback - Normal Input: Feedback - Contact 1 Input: Feedback - Contact 2 Output: Pulse 1 Output: Pulse 2 Output: Pulse 1 - Soft Reset Output: Pulse 2 - Soft Reset Output: Pulse 1 - Hard Reset Output: Pulse 2 - Hard Reset Output: Fixed 1 - On Output: Fixed 1 - Off Output: Fixed 1 - On - Blinking Output: Fixed 1 - Off - Blinking Output: Fixed 1 - On - 4-Way Output: Fixed 1 - Off - 4-Way Output: Fixed 1 - On - 4-Way - Blinking Output: Fixed 1 - Off - 4-Way - Blinking Output: Fixed 2 - On Output: Fixed 2 - Off Output: Fixed 2 - On - Blinking Output: Fixed 2 - Off - Blinking Output: Fixed 2 - On - 4-Way Output: Fixed 2 - Off - 4-Way Output: Fixed 2 - On - 4-Way - Blinking Output: Fixed 2 - Off - 4-Way - Blinking Output: Block Detector (odd address) Uitgang: Bezetmelder (oneven) Output: Block Detector (even address) Uitgang: Bezetmelder (even) Output: Block Detector - Blinking (odd) Uitgang: Bezetmelder - knipperend (oneven) Output: Block Detector - Blinking (even) Uitgang: Bezetmelder - knipperend (even) Select Port 16 operation mode. Sets Config and Value2 Port Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Port 16 Config and Value2 for RCD connection.
Select only one active port on this LocoRCD board
Ports Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Select Port 1+2 operation mode. Sets Config and Value2
Use just one pair of active ports on this LocoRCD2 board
Ports Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Select Port 3+4 operation mode. Sets Config and Value2
Use just one pair of active ports on this LocoRCD2 board
Ports Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Select Port 5+6 operation mode. Sets Config and Value2
Use just one pair of active ports on this LocoRCD2 board
Ports Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Select Port 7+8 operation mode. Sets Config and Value2
Use just one pair of active ports on this LocoRCD2 board
Ports Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Select Port 9+10 operation mode. Sets Config and Value2
Use just one pair of active ports on this LocoRCD2 board
Ports Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Select Port 11+12 operation mode. Sets Config and Value2
Use just one pair of active ports on this LocoRCD2 board
Ports Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Select Port 13+14 operation mode. Sets Config and Value2
Use just one pair of active ports on this LocoRCD2 board
Ports Not In Use Anschluss nicht benutzt Poort niet in gebruik Input: Block Detector - active Low (odd address) Input: Block Detector - active Low (even address) Input: Block Detector - active Low Delayed (odd) Input: Block Detector - active Low Delayed (even) Select Port 15+16 operation mode. Sets Config and Value2
Use just one pair of active ports on this LocoRCD2 board
Select... Selecteer... No action Port 1 Poort 1 Port 2 Poort 2 Port 3 Poorte3 Port 4 Poort 4 Port 5 Poort 5 Port 6 Poort 6 Port 7 Poort 7 Port 8 Poort 8 Port 9 Poort 9 Port 10 Poort 10 Port 11 Poort 11 Port 12 Poort 12 Port 13 Poort 13 Port 14 Poort 14 Port 15 Poort 15 Port 16 Poort 16 Select a unique 2-port set between all boards that share one RCD2 Board address Select... Selecteer... No action Ports 1-2 Poorten 1-2 Ports 3-4 Poorten 3-4 Ports 5-6 Poorten 5-6 Ports 7-8 Poorten 7-8 Ports 9-10 Poorten 9-10 Ports 11-12 Poorten 11-12 Ports 13-14 Poorten 13-14 Ports 15-16 Poorten 15-16 Select a unique 2-port set between all boards that share one RCD2 Board address
Loco... Short Address eq 80 Ports Anschlüsse Poorten Special Ports eq 0 Port1 OccuMode ne 1 Port1 OccuMode eq 1 Port1 SensorAddress eq 2 Special Ports eq 1 Port1 Type ne 0 Special Ports eq 0 Special Ports eq 0 Port2 OccuMode ne 1 Port2 OccuMode eq 1 Special Ports eq 1 Special Ports eq 0 Special Ports eq 0 Port3 OccuMode ne 1 Port3 OccuMode eq 1 Special Ports eq 1 Port3 Type ne 0 Special Ports eq 0 Special Ports eq 0 Port4 OccuMode ne 1 Port4 OccuMode eq 1 Special Ports eq 1 Special Ports eq 0 Port5 OccuMode ne 1 Port5 OccuMode eq 1 Port5 Type ne 0 Port6 OccuMode ne 1 Port6 OccuMode eq 1 Action Mode eq 2 Action Mode eq 3 Action Mode eq 2 Action Mode eq 3 Port7 OccuMode ne 1 Port7 OccuMode eq 1 Port7 Type ne 0 Port8 OccuMode ne 1 Port8 OccuMode eq 1 Action Mode eq 2 Action Mode eq 3 Action Mode eq 2 Action Mode eq 3 Port9 OccuMode ne 1 Port9 OccuMode eq 1 Port9 Type ne 0 Port10 OccuMode ne 1 Port10 OccuMode eq 1 Action Mode eq 2 Action Mode eq 3 Action Mode eq 2 Action Mode eq 3 Port11 OccuMode ne 1 Port11 OccuMode eq 1 Port11 Type ne 0 Port12 OccuMode ne 1 Port12 OccuMode eq 1 Action Mode eq 2 Action Mode eq 3 Action Mode eq 2 Action Mode eq 3 Port13 OccuMode ne 1 Port13 OccuMode eq 1 Port13 Type ne 0 Port14 OccuMode ne 1 Port14 OccuMode eq 1 Port15 OccuMode ne 1 Port15 OccuMode eq 1 Port15 Type ne 0 Port16 OccuMode ne 1 Port16 OccuMode eq 1 ReadMe Lese Mich Lisez Moi Lees Mij Cheat Sheet Spiekblad