Range 0-255, 0 in CV 2, 6, 5 produces straight line accelerationRange 0-255Range 0-255Range 0-255, A value of 255 corresponds to 100%. 0 in CV 2, 6, 5 produces straight line accelerationRange 0-255, 0 in CV 2, 6, 5 produces straight line accelerationDefault SettingsShunterLight FreightHeavy FreightExpress FreightLight EngineLocal/Branch PassengeStopping PassengerExpress PassengeEMU/DMUNo FlickerH/L On,O/P 2-6 Flicker-On (F0)All Flicker-On(F0)All Flicker-On (F0-F4)H/L On,O/P 2-6 Flicker-On (F0-F4)All Flicker-On (F0-F4)<html>Physical output "White" (default F0f)<br>Not documented, values to be confirmed.</html>Physical output "White" (default F0f)<html>Physical output "Yellow" (default F0r)<br>Not documented, values to be confirmed.</html>Physical output "Yellow" (default F0r)<html>Physical output "Green" (default F1)<br>Not documented, values to be confirmed.</html>Physical output "Green" (default F1)<html>Physical output "Purple" (default F2)<br>Not documented, values to be confirmed.</html>Physical output "Purple" (default F2)Physical output "Pink" (default F3)Physical output "Pink" (default F3)Physical output "Brown" (default F4)Physical output "Brown" (default F4)ADCC/ABC OffABC Unit LeftABC Unit RightBoth Rails DetectedAuto ShuttleRange 1-255 - 0.1sec steps0-Decel(CV4)1-Decel(CV58)2-Slow to Speed(CV57)3-Decel(CV58)+Speed(57)0-Intermediate Stations Stop for Time(CV60)1-Intermediate StationStop until released2-Stop at Terminal, Set Speed to ZEROSets Speed for SLOW section (Range 1-64)Sets ABC Decel Rate (1-255)Sets wait time at end of shuttle (1-255 - 10sec to 42min))Sets wait time at end of shuttle (1-255 - 10sec to 42min))<html>Format: yyx<br>Year 201x = last digit x<br>Month = yy <br>e.g. 25 = 2nd month, 2015<br>e.g. 115 = 11th month, 2015</html><html>Disable(default)/Enable button control of BEMF<br>BEMF control button to be selected on function map.</html><html>Motor controlled by Function button<br>Motor control button to be selected on function map.</html>F2 Forward, F3 ReverseF2 On/Off<html>If motor button control is enabled.<br>Use forward/reverse buttons if "F2 On/Off" selected.</html>1 second = about 12 (tbc)Range: 1-30Range: 1-5Range: 1-3Range: 1-24Range: 1-24Range: 1-128Range: 1-24Range: 1-24Range: 1-3Range: 1-24Range: 1-24Range 0-255Range 0-255Range 0-255Range 0-255Range 0-255Range 0-255Range 0-255Range 0-255<html>If motor button control is enabled.<br>Power level (drive voltage) for button control of the motor circuit (range 0-255)</html><html>adjusting this CV can make firebox flicker work differently<br>to emulate gas or oil lamp flicker</html>MomentumDecoder LockingOne Step Set UpABC Breaking